- 150-F317NCDB
The Rockwell 150-F317NCDB is an SMC Flex soft starter rated 317 A and 125–250 Hp at 460V AC, with 200...600V AC (-15%, +10%) rated operational voltage per UL/CSA/NEMA for the power circuit and 100...240V AC control voltage. It has an integrated display, internal bypass, integrated motor overload protection, and trip classes 10, 15, 20, and 30. Line-connected motor current is 106...317 A at 600/Y/690V AC, 3-phase; delta-connected motor current is 183...549 A at 500/575V AC, 3-phase. Operating temperature is -5 to 50 °C open type, humidity 5...95% noncondensing, altitude 2000 m. Dimensions are 290 mm width, 276.5 mm depth, 600 mm height.
- 150-F317NZDB
Product identification: ROCKWELL 150-F317NZDB. The Allen-Bradley 150-F317NZDB is an SMC Flex soft starter with an integrated display. It is rated 317 A and 125–250 hp at 460 V AC, with a control voltage of 100...240 V AC. Overload current is 106 A for line-connected devices and 183 A for delta-connected devices. Control options include pump control.
- 150-F361NBD
The Rockwell 150-F361NBD is an SMC Flex soft starter with a 361 A controller rating, rated 150–300 Hp at 460 V AC. It has a 200–480 V AC (-15%, +10%) rated operational voltage per UL/CSA/NEMA for the power circuit, 50/60 Hz operating frequency, and 200–480 V AC input. Control voltage is 100–240 V AC. It includes a display, integrated motor overload protection, internal bypass, and trip classes 10, 15, 20, and 30. Line-connected motor current is 120–361 A at 600/Y/690 V AC, 3-phase; delta-connected motor current is 208–625 A at 500/575 V AC, 3-phase. The open-type enclosure measures 290 mm wide, 276.5 mm deep, and 600 mm high.
- 150-F361NBDD
The Rockwell 150-F361NBDD is an SMC Flex soft starter with a 361 A controller rating and 150–300 Hp at 460 V AC. The rated operating voltage Ue is 200 V, and control voltage is 100...240 V AC. It includes a display and supports brake control. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor full-load current. Overload current is 120 A for line-connected devices and 208 A for delta-connected devices. The power circuit uses an RC snubber network for DV/DT protection, operates at 50/60 Hz, and has a repetitive peak inverse voltage rating of 1400 V per UL/CSA/NEMA. Maximum line-connected motor power is 450 Hp at 600 V AC, 60 Hz, three-phase.
- 150-F361NCDB
The Rockwell 150-F361NCDB is an SMC Flex soft starter with a 361 A controller rating, rated 150–300 Hp at 460V AC. It operates on three-phase power at 50/60 Hz with a rated operational voltage of 200...600V AC (-15%, +10%) per UL/CSA/NEMA. Control voltage is 100...240V AC. Integrated motor overload protection is included, with trip classes 10, 15, 20 and 30 and trip current at 117% of motor FLC. Line-connected motor current is 120...361 A at 600/Y/690V AC; delta-connected motor current is 208...625A at 500/575V AC. The open-type unit has an internal bypass, a display, and IP2X protection with terminal covers per IEC. Dimensions are 290 mm wide, 276.5 mm deep, and 600 mm high.
- 150-F361NCRB
The Rockwell 150-F361NCRB is an SMC Flex soft starter with a 361 A controller rating for 150–300 Hp at 460 V AC. It operates on 200–600 V AC (-15%, +10%) per UL/CSA/NEMA, 50/60 Hz, three-phase, with 24 V AC/DC control. Line-connected motor current is 120–361 A at 600/Y/690 V AC; delta-connected current is 208–625 A at 500/575 V AC. Integrated motor overload protection, internal bypass, and trip classes 10, 15, 20, and 30 are included. The open-type enclosure measures 290 mm wide, 276.5 mm deep, and 600 mm high, with an operating temperature of -5 to 50 °C (23 to 122 °F).
- 150-F361NCRD
The ROCKWELL 150-F361NCRD is a SMC Flex soft starter with a controller rating of 361 A and 150–300 Hp at 460 V AC. It operates from a 24 V AC/DC control supply and supports 50/60 Hz power circuits. Line-connected motor current ranges from 120 to 361 A at 600/Y/690 V AC, three-phase; delta-connected current ranges from 208 to 625 A at 500/575 V AC, three-phase. Integrated motor overload protection is included, with trip classes 10, 15, 20 and 30. The unit has a display, internal bypass, three poles, and an open-type enclosure. Dimensions are 290 mm wide, 276.5 mm deep, and 600 mm high. Operating temperature is -5 to 50 °C open. Weight is 34.915 kg.
- 150-F361NZD
The Rockwell 150-F361NZD is an SMC Flex soft starter with a 361 A controller rating for 150–300 Hp motors at 460 V AC. It operates on a 230 V rated operating voltage with a 100...240 V AC control voltage and 50/60 Hz power circuit frequency. The unit includes a display and no control options. Overload current is 120 A for line-connected devices and 208 A for delta-connected devices, with trip classes 10, 15, 20, and 30 and a trip current rating of 117% of motor FLC. Maximum line-connected motor power is 450 Hp at 600 V AC, 60 Hz, three-phase; maximum delta-connected motor power is 600 Hp at 575 V AC, 60 Hz, three-phase.