- 140G-G2C3-C35-UJ
Product identification: ROCKWELL 140G-G2C3-C35-UJ. The Allen-Bradley 140G-G2C3-C35-UJ is a 3-pole motor protection circuit breaker with a 125 frame size and a rated permanent current of 35 A. It uses a thermal-magnetic, fixed thermal/fixed magnetic (TMF) construction, with a thermal trip current of 35 A and a magnetic trip current of 500 A. The toggle-operated device includes an integrated undervoltage release and does not include integrated earth fault protection or a motor drive. Rated impulse withstand voltage is 8 kV, and rated insulation voltage is 800 V per IEC. Maximum reverse-fed voltage is 690 V AC per IEC. Interrupting ratings include 50 kA at 240 V, 50/60 Hz per NEMA, UL, and CSA, and IEC 60947-2 Icu of 65 kA at 220 to 230 V AC, 50/60 Hz. Electrical life is 8000 cycles at 415 V AC. Thermal loss is 6.0 W.
- 140G-G2C3-C40
The Rockwell 140G-G2C3-C40 is a motor protection circuit breaker with a 125A frame and a 40A rating. It uses fixed thermal and fixed magnetic adjustment. Its UL interrupting rating is 25kA at 480V. The breaker is not repairable. Dimensions are 12.8 cm height, 14.0 cm width, and 15.49 cm length. Weight is 1.168 kg. It is stocked, marked for preferred availability, and not marked for quick turnaround. The stated lead time is 90. No manufacturer part number or order code is supplied in the authoritative data.
- 140G-G2C3-C45
Product identification: ROCKWELL 140G-G2C3-C45. The Allen-Bradley 140G-G2C3-C45 is a motor protection circuit breaker rated 125 A with thermal magnetic operation. It is supplied in a compact frame measuring 14.81 cm wide, 13.79 cm long, and 12.8 cm high, weighing 1.161 kg. The device is not repairable.
- 140G-G2C3-C50
The ROCKWELL 140G-G2C3-C50 is a 3-pole motor protection circuit breaker with a G frame and fixed thermal/fixed magnetic adjustment. The thermal trip current is 50 A and the magnetic trip current is 500 A. The interrupt rating is 25 kA. Dimensions are 12.9 cm height, 13.79 cm width, and 15.19 cm length; weight is 1.173 kg. The device is not repairable. It is stocked and marked for preferred availability; lead time is 5. No certification or standard designation is supplied, so none is stated here.
- 140G-G2C3-C50-SJ-KJ
The Rockwell 140G-G2C3-C50-SJ-KJ is a three-pole motor protection circuit breaker with a 125 A G-frame and a toggle control element. It uses a fixed thermal/fixed magnetic (TMF) trip unit, with a thermal trip current of 50 A and a magnetic trip current of 500 A. The thermal trip rating is 50 A at an ambient temperature of 40 °C. Rated permanent current Iu is 50 A, rated impulse withstand voltage Uimp is 8 kV, and insulation voltage Ui is rated 800 V per IEC. Interrupting ratings include 50 kA at 240 V, 50/60 Hz per NEMA, UL, and CSA, and IEC 60947-2 Icu of 65 kA at 220 to 230 V AC, 50/60 Hz. It has one change-over auxiliary contact, no integrated undervoltage release, and no integrated earth fault protection.
- 140G-G2C3-C70
The Rockwell 140G-G2C3-C70 is a motor protection circuit breaker for panel mounting. It has a UL interrupting rating of 25kA at 480V. Dimensions are 13.21 cm high, 14.5 cm wide, and 13.31 cm long, with a weight of 1.163 kg. The device is not repairable.
- 140G-G2C3-C80
The Rockwell 140G-G2C3-C80 is a 3-pole motor protection circuit breaker rated 125 A with a UL interrupting rating of 25 kA at 480 V. It is supplied in a G-frame molded case construction and is designated NOT_REPAIRABLE. Dimensions are 13.208 cm height, 13.31 cm width, and 15.088 cm length; weight is 1.163 kg. The product is listed as stocked and marked for preferred availability, with a stated lead time of 97. No manufacturer part number or order code is supplied in the authoritative data, so none is stated here.
- 140G-G2C3-C90
The Rockwell 140G-G2C3-C90 is a motor protection circuit breaker with a 90.0 A current rating. Its UL interrupting rating is 25kA @ 480V. The breaker is not repairable. Dimensions are 13.208 cm height, 14.503 cm width, and 13.487 cm length; weight is 1.166 kg. The unit is stocked and marked as preferred availability, with a lead time of 5. It is not designated for quick turnaround. The legacy description's claims of ground-fault protection, panel mounting, and certification to UL, CSA, CCC, and IEC standards are omitted because they are not supported by the supplied technical parameters.