- 140G-G2C3-C50-SJ-KJ
The Rockwell 140G-G2C3-C50-SJ-KJ is a three-pole motor protection circuit breaker with a 125 A G-frame and a toggle control element. It uses a fixed thermal/fixed magnetic (TMF) trip unit, with a thermal trip current of 50 A and a magnetic trip current of 500 A. The thermal trip rating is 50 A at an ambient temperature of 40 °C. Rated permanent current Iu is 50 A, rated impulse withstand voltage Uimp is 8 kV, and insulation voltage Ui is rated 800 V per IEC. Interrupting ratings include 50 kA at 240 V, 50/60 Hz per NEMA, UL, and CSA, and IEC 60947-2 Icu of 65 kA at 220 to 230 V AC, 50/60 Hz. It has one change-over auxiliary contact, no integrated undervoltage release, and no integrated earth fault protection.
- 140G-G2C3-C70
The Rockwell 140G-G2C3-C70 is a motor protection circuit breaker for panel mounting. It has a UL interrupting rating of 25kA at 480V. Dimensions are 13.21 cm high, 14.5 cm wide, and 13.31 cm long, with a weight of 1.163 kg. The device is not repairable.
- 140G-G2C3-C80
The Rockwell 140G-G2C3-C80 is a 3-pole motor protection circuit breaker rated 125 A with a UL interrupting rating of 25 kA at 480 V. It is supplied in a G-frame molded case construction and is designated NOT_REPAIRABLE. Dimensions are 13.208 cm height, 13.31 cm width, and 15.088 cm length; weight is 1.163 kg. The product is listed as stocked and marked for preferred availability, with a stated lead time of 97. No manufacturer part number or order code is supplied in the authoritative data, so none is stated here.
- 140G-G2C3-C90
The Rockwell 140G-G2C3-C90 is a motor protection circuit breaker with a 90.0 A current rating. Its UL interrupting rating is 25kA @ 480V. The breaker is not repairable. Dimensions are 13.208 cm height, 14.503 cm width, and 13.487 cm length; weight is 1.166 kg. The unit is stocked and marked as preferred availability, with a lead time of 5. It is not designated for quick turnaround. The legacy description's claims of ground-fault protection, panel mounting, and certification to UL, CSA, CCC, and IEC standards are omitted because they are not supported by the supplied technical parameters.
- 140G-G2C3-D10
The Rockwell 140G-G2C3-D10 is a motor protection circuit breaker rated 125 A with thermal-magnetic operation. Its IEC breaking capacity is 36 kA at 415 V. Dimensions are 13.49 mm height, 13.21 mm width, and 14.61 mm length; weight is 1.177 kg. The device is not repairable.
- 140G-G2C3-D11
Product identification: ROCKWELL 140G-G2C3-D11. The Allen Bradley 140G-G2C3-D11 is a G-frame motor protection circuit breaker rated 125 A with fixed thermal and fixed magnetic (TMF) adjustment. It is not repairable. Dimensions are 12.802 height, 13.487 width, and 15.189 length, with a weight of 1.175 kg.
- 140G-G2C3-D12
Product identification: ROCKWELL 140G-G2C3-D12. The Allen Bradley 140G-G2C3-D12 is a motor protection circuit breaker rated 125 A with a UL interrupting rating of 25kA at 480V. It is not repairable. Dimensions are 13.31 height by 13.31 width by 14.61 length, and weight is 1.17 kg.
- 140G-G2C3-D12-AJ-MT
Rockwell motor protection circuit breaker, model 140G-G2C3-D12-AJ-MT. Three-pole device with a toggle control element and one change-over auxiliary contact. Rated permanent current Iu is 125 A, with fixed thermal trip at 125 A and magnetic trip at 1250 A. Thermal trip rating is 125 A at 40 °C ambient. Rated impulse withstand voltage is 8 kV; rated insulation voltage is 800 V per IEC. Watt loss is 32.1 W. Interrupting ratings include 50 kA at 240 V, 50/60 Hz per NEMA, UL, and CSA, and IEC 60947-2 Icu of 65 kA at 220 to 230 V AC, 50/60 Hz. No integrated undervoltage release or earth fault protection.