- GDA202 A S-40/0.1
ABB GDA202 A S-40/0.1 is a Type A residual current device block with a selective operating characteristic. It has a rated current of 40 A, rated residual current of 100 mA, rated voltage of 230 V, rated insulation voltage of 500 V, and rated impulse withstand voltage of 4 kV. Rated frequency is 50 to 60 Hz, with two poles and a maximum surge current of 3 kA. Connecting capacity is rigid 25 mm² and flexible 25 mm². Ambient operating temperature is -25 to 55 °C, degree of protection is IP2X, and pollution degree is 2. Product net dimensions are 0.070 m width, 0.093 m height, and 0.069 m depth, with a net weight of 0.174 kg.
- GDA202 A S-40/0.3
ABB GDA202 A S-40/0.3 leakage protector, Type A residual current device. Rated current 40 A, rated residual current 300 mA, selective operating characteristic. Rated voltage 230 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, maximum surge current 3 kA. Rated frequency 50 to 60 Hz, two poles. Connecting capacity rigid 25 mm² and flexible 25 mm². Ambient operating temperature -25 to 55 °C, degree of protection IP2X, pollution degree 2. Dimensions 0.070 m width, 0.093 m height, 0.069 m depth; net weight 0.174 kg. Manufacturer ID 2TAZ810206R4400.
- GDA202 A S-63/0.1
The ABB GDA202 A S-63/0.1 is a Type A residual current device block with a rated residual current of 100 mA and a rated current of 63 A. It has two poles and a selective operating characteristic. Rated operational voltage is 230 V AC at 50 to 60 Hz. Rated insulation voltage is 500 V and rated impulse withstand voltage is 4 kV. Maximum surge current is 3 kA. Connecting capacity is 25 mm² rigid and 25 mm² flexible. Ambient operating temperature range is -25 to 55 °C. Degree of protection is IP2X and pollution degree is 2. It conforms to IEC 61009 and GB 16917. Net dimensions are 0.070 m width, 0.093 m height, and 0.069 m depth; net weight is 0.174 kg.
- GDA202 A-25/0.03
ABB GDA202 A-25/0.03 leakage protector, manufacturer ID 2TAZ812204R2250. Type A residual current device, 2-pole, rated current 25 A, rated residual current 30 mA, instantaneous operating characteristic. Rated voltage 230 V AC, rated frequency 50 to 60 Hz, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, maximum surge current 0.25 kA. Connecting capacity rigid 25 mm² and flexible 25 mm². Ambient operating temperature -25 to 55 °C, degree of protection IP2X, pollution degree 2. Standards IEC 61009 and GB 16917. Net dimensions 0.070 m width, 0.093 m height, 0.069 m depth; net weight 0.154 kg. ETIM 8 and ETIM 9 classification EC002297.
- GDA202 A-40/0.03
ABB GDA202 A-40/0.03 leakage protector, manufacturer ID 2TAZ812204R2400. Type A residual current device, 2-pole, rated current 40 A, rated residual current 30 mA, instantaneous operating characteristic. Rated voltage 230 V AC, rated frequency 50 to 60 Hz, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, maximum surge current 0.25 kA. Standards: IEC 61009, GB 16917. Connecting capacity rigid 25 mm² and flexible 25 mm². Ambient operating temperature -25 to 55 °C, degree of protection IP2X, pollution degree 2. Dimensions 0.070 m width, 0.093 m height, 0.069 m depth; net weight 0.174 kg.
- GDA202 A-40/0.03 AP-R
ABB GDA202 A-40/0.03 AP-R leakage protector, manufacturer ID 2TAZ812205R2400. Type A residual current device, 2-pole, rated current 40 A, rated residual current 30 mA, rated voltage 230 V AC, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, maximum surge current 3 kA. Rated frequency 50 to 60 Hz. Instantaneous operating characteristic (APR high immunity). Connecting capacity rigid and flexible 25 mm². Ambient operating temperature -25 to 55 °C. Degree of protection IP2X, pollution degree 2. Standards IEC 61009 and GB 16917. Net dimensions 0.070 m width, 0.093 m height, 0.069 m depth; net weight 0.174 kg.
- GDA202 A-40/0.1 AP-R
ABB GDA202 A-40/0.1 AP-R leakage protector, manufacturer ID 2TAZ812205R3400. Type A residual current device, 2-pole, rated current 40 A, rated residual current 100 mA, rated voltage 230 V AC, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Instantaneous operating characteristic (APR high immunity). Maximum surge current 3 kA. Standards: IEC 61009, GB 16917. Connecting capacity rigid 25 to 25 mm², flexible 25 to 25 mm². Ambient operating temperature -25 to 55 °C, pollution degree 2, degree of protection IP2X. Dimensions 0.070 m width, 0.093 m height, 0.069 m depth; net weight 0.174 kg.
- GDA202 AC S-25/0.1
ABB leakage protector GDA202 AC S-25/0.1, manufacturer ID 2TAZ810203R3250. Type AC residual current device, 2-pole, rated current 25 A, rated residual current 100 mA, selective operating characteristic. Rated voltage 230 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, maximum surge current 3 kA, rated frequency 50 to 60 Hz. Connecting capacity rigid and flexible 25 mm². Ambient operating temperature -25 to 55 °C, degree of protection IP2X, pollution degree 2. Dimensions 0.070 m width, 0.093 m height, 0.069 m depth; net weight 0.154 kg. ETIM 8 and ETIM 9 classification EC002297, residual current circuit breaker (RCCB) module.