- GDA202 A-40/0.03 AP-R
ABB GDA202 A-40/0.03 AP-R leakage protector, manufacturer ID 2TAZ812205R2400. Type A residual current device, 2-pole, rated current 40 A, rated residual current 30 mA, rated voltage 230 V AC, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, maximum surge current 3 kA. Rated frequency 50 to 60 Hz. Instantaneous operating characteristic (APR high immunity). Connecting capacity rigid and flexible 25 mm². Ambient operating temperature -25 to 55 °C. Degree of protection IP2X, pollution degree 2. Standards IEC 61009 and GB 16917. Net dimensions 0.070 m width, 0.093 m height, 0.069 m depth; net weight 0.174 kg.
- GDA202 A-40/0.1 AP-R
ABB GDA202 A-40/0.1 AP-R leakage protector, manufacturer ID 2TAZ812205R3400. Type A residual current device, 2-pole, rated current 40 A, rated residual current 100 mA, rated voltage 230 V AC, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz. Instantaneous operating characteristic (APR high immunity). Maximum surge current 3 kA. Standards: IEC 61009, GB 16917. Connecting capacity rigid 25 to 25 mm², flexible 25 to 25 mm². Ambient operating temperature -25 to 55 °C, pollution degree 2, degree of protection IP2X. Dimensions 0.070 m width, 0.093 m height, 0.069 m depth; net weight 0.174 kg.
- GDA202 AC S-25/0.1
ABB leakage protector GDA202 AC S-25/0.1, manufacturer ID 2TAZ810203R3250. Type AC residual current device, 2-pole, rated current 25 A, rated residual current 100 mA, selective operating characteristic. Rated voltage 230 V, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, maximum surge current 3 kA, rated frequency 50 to 60 Hz. Connecting capacity rigid and flexible 25 mm². Ambient operating temperature -25 to 55 °C, degree of protection IP2X, pollution degree 2. Dimensions 0.070 m width, 0.093 m height, 0.069 m depth; net weight 0.154 kg. ETIM 8 and ETIM 9 classification EC002297, residual current circuit breaker (RCCB) module.
- GDA202 AC S-40/0.1
The ABB GDA202 AC S-40/0.1 is a Type AC residual current device block with a rated current of 40 A and rated residual current of 100 mA. It has a selective operating characteristic and is rated 230 V AC, 50 to 60 Hz, with two poles. Rated insulation voltage is 500 V, rated impulse withstand voltage is 4 kV, and maximum surge current is 3 kA. Connecting capacity is 25 mm² for both rigid and flexible conductors. Ambient operating temperature range is -25 to 55 °C, degree of protection is IP2X, and pollution degree is 2. It conforms to IEC 61009 and GB 16917. Net dimensions are 0.070 m width, 0.093 m height, and 0.069 m depth; net weight is 0.174 kg.
- GDA202 AC S-40/0.3
ABB leakage protector, model GDA202 AC S-40/0.3, manufacturer ID 2TAZ812203R4400. Type AC residual current device, 2-pole, rated current 40 A, rated residual current 300 mA, selective operating characteristic. Rated voltage 230 V AC, rated frequency 50 to 60 Hz, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, maximum surge current 3 kA. Standards: IEC 61009, GB 16917. Connecting capacity rigid 25 mm², flexible 25 mm². Ambient operating temperature -25 to 55 °C, degree of protection IP2X, pollution degree 2. Dimensions 0.070 m width, 0.093 m height, 0.069 m depth; net weight 0.174 kg.
- GDA202 AC S-63/0.3
The ABB GDA202 AC S-63/0.3 is a Type AC residual current device module. It has a rated current of 63 A, a rated residual current of 300 mA, and a selective operating characteristic. Rated voltage is 230 V AC at 50 to 60 Hz, with a rated insulation voltage of 500 V and a rated impulse withstand voltage of 4 kV. Maximum surge current is 3 kA. It has two poles, IP2X degree of protection, pollution degree 2, and operates from -25 to 55 °C. Connecting capacity is rigid 25 mm² and flexible 25 mm². Standards: IEC 61009 and GB 16917. Dimensions are 0.070 m width, 0.093 m height, 0.069 m depth; net weight 0.174 kg.
- GDA202 AC-25/0.03
The ABB GDA202 AC-25/0.03 is a leakage protector supplied under manufacturer ID 2TAZ846201R2250. It is a miniature residual current protection circuit breaker intended for assembly with MCBs of the S200 series. It provides protection against sinusoidal alternating earth fault currents and against indirect contacts. Net dimensions are 0.070 m width, 0.093 m height, and 0.069 m depth; net weight is 0.154 kg. Object classification code is F. WEEE category 5 covers small equipment with no external dimension more than 50 cm, and the WEEE B2C / B2B designation is Business To Consumer. CN8 code is 8536200000.
- GDA202 AC-40/0.03
ABB GDA202 AC-40/0.03 leakage protector, manufacturer ID 2TAZ813201R2400. Type AC residual current device rated 40 A with 30 mA rated residual current, 2 poles, instantaneous operating characteristic. Rated voltage 230 V AC, rated insulation voltage 500 V, rated impulse withstand voltage 4 kV, rated frequency 50 to 60 Hz, maximum surge current 0.25 kA. Connecting capacity rigid 25 mm² and flexible 25 mm². Ambient operating temperature -25 to 55 °C, degree of protection IP2X, pollution degree 2. Standards IEC 61009 and GB 16917. Dimensions 0.070 m width, 0.093 m height, 0.069 m depth; net weight 0.154 kg.