- 150-F43NBR
The Rockwell 150-F43NBR is a SMC Flex soft starter with a 43 A controller rating and 7.5–30.0 Hp at 460 V AC. It operates on 200–480 V AC (-15%, +10%) per UL/CSA/NEMA for the power circuit, 3-phase, 50/60 Hz, with 24 V AC/DC control voltage. Line-connected motor current is 8.6–43 A at 500/575 V AC, 3-phase; delta-connected current is 14.9–74 A. It includes an integrated bypass, integrated motor overload protection, and a display. Trip classes are 10, 15, 20 and 30. The open-type enclosure is IP20 per IEC for the power circuit. Operating temperature is -5 to 50 °C (23 to 122 °F). Dimensions are 150 mm width, 203 mm depth, and 321 mm height.
- 150-F43NCD
The Rockwell 150-F43NCD is an SMC Flex soft starter with an integrated display and internal bypass. It operates on 100...240V AC control voltage and is rated 43 A, 7.5-30.0 Hp at 460V AC. The power circuit is rated 200...600V AC (-15%, +10%) per UL/CSA/NEMA, 50/60 Hz, three-phase, with a rated impulse voltage of 6000V per IEC and dielectric withstand of 2500V per IEC. Line-connected motor current is 8.6...43A at 500/575V AC, three-phase; delta-connected motor current is 14.9...74A at 500/575V AC, three-phase. Integrated motor overload protection is included, with trip classes 10, 15, 20 and 30 and trip current rating 117% of motor FLC. Enclosure is open type, IP20 per IEC for the power circuit.
- 150-F43NCDB
The Rockwell 150-F43NCDB is an SMC Flex smart motor controller configured as a soft starter with pump control. Its controller rating is 43 A, 7.5-30.0 Hp at 460V AC, and it includes a display. Control voltage is 100...240V AC, with rated control supply voltage of 100V AC at both 50 Hz and 60 Hz. The power circuit operates at 50/60 Hz. Overload current is 8.6 A for line-connected devices and 14.8 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with a trip current rating of 117% of motor FLC. The transformer control module is rated 75VA at 100...240V AC (-15%, +10%).
- 150-F43NCDD
The Rockwell 150-F43NCDD is a SMC Flex soft starter with an integrated display. It is rated 43 A and 7.5–30.0 Hp at 460 V AC, with a maximum line-connected motor power of 40 Hp at 575 V AC, 60 Hz, three-phase. Control voltage is 100–240 V AC. The controller provides brake control and trip classes 10, 15, 20, and 30, with a trip current rating of 117% of motor FLC. Overload current is 8.6 A for line-connected devices and 14.8 A for delta-connected devices. The power circuit uses an RC snubber network for DV/DT protection and is rated 1600 V repetitive peak inverse voltage per UL/CSA/NEMA, operating at 50/60 Hz.
- 150-F480NBR
The Rockwell 150-F480NBR is an SMC Flex smart motor controller configured as a soft starter with integrated motor overload protection and an internal bypass. It provides a 480 A controller rating, 200-400 Hp at 460V AC, and operates on 200-480V AC, 3-phase, 50/60 Hz power with a 24V AC/DC control supply. Trip classes are 10, 15, 20 and 30, with trip current at 117% of motor FLC. Line-connected motor current is 160...480 A at 600/Y/690V AC, 3-phase; delta-connected motor current is 277...831 A at 500/575V AC, 3-phase. The open-type unit includes a display, status indication, and programmable NO/NC auxiliary contacts. Dimensions are 290 mm wide, 276.5 mm deep, and 600 mm high.
- 150-F480NBRD
The Rockwell 150-F480NBRD is a soft starter in the SMC Flex product family with an integrated display. It operates on a 24V AC/DC control supply at 50 Hz or 60 Hz and a rated operating voltage Ue of 200. Overload current ratings are 160 A for line-connected devices and 277 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with a trip current rating of 117% of motor FLC. Maximum line-connected motor power is 600 Hp at 600V AC, 60 Hz, three-phase; maximum delta-connected motor power is 900 Hp at 575V AC, 60 Hz, three-phase. Control options include brake control. The power circuit uses an RC snubber network for DV/DT protection and has a repetitive peak inverse voltage rating of 1400V per UL/CSA/NEMA.
- 150-F480NCD
The Rockwell 150-F480NCD is an SMC Flex soft starter with an integrated display. Its controller rating is 480 A and 200–400 Hp at 460 V AC. The rated operating voltage Ue is 200 V, and control voltage is 100...240 V AC at both 50 Hz and 60 Hz. Power-circuit operating frequency is 50/60 Hz. Overload current is 160 A for line-connected devices and 277 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with trip current rating 117% of motor FLC. Maximum line-connected motor power is 600 Hp at 600 V AC, 60 Hz, three-phase. The transformer control module is rated 75VA at 100...240 V AC (-15%, +10%).
- 150-F480NCDB
The Rockwell 150-F480NCDB is an SMC Flex soft starter with an integrated display and internal bypass, intended for single-direction three-phase motor control. The controller is rated 480 A and 200–400 Hp at 460V AC. Line-connected motor current is 160–480 A at 600/Y/690V AC, three-phase, with maximum line-connected motor power of 600 Hp at 600V AC, 60 Hz, three-phase. Rated operational voltage is 200–600V AC (-15%, +10%) per UL/CSA/NEMA for the power circuit, at 50/60 Hz. Control voltage is 100–240V AC. Integrated motor overload protection is included, with trip classes 10, 15, 20 and 30. The open-type enclosure measures 290 mm wide, 276.5 mm deep and 600 mm high, and weighs 54.885 kg.