Product Model
150-F480NBRD
Material Number
—
Manufacturer
ROCKWELL
Product ID
105216

Get a Free Quote

Request pricing and availability for 150-F480NBRD.

More parts to source? Send your whole list in one enquiry

Key specifications

Control Voltage
24V AC/DC
Rated operating voltage Ue
200
DV/DT protection
RC snubber network for power circuit
Operating frequency
50/60 Hz for power circuit
Rated operational current
3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts
Weight
44.928
See all specifications

Product Highlights

  1. Soft Starter Control: SMC Flex controller with single-direction operation, integrated motor overload protection, and programmable NO/NC auxiliary contacts
  2. Current and Power Ratings: Line-connected motor current 160 to 480 A at 600/690 V AC 3-phase with maximum 600 Hp at 600 V AC, delta-connected motor current 277 to 831 A at 500/575 V AC 3-phase with maximum 900 Hp at 575 V AC
  3. Operating Voltage and Frequency: Rated operational voltage 200 to 480 V AC (-15%, +10%) per UL/CSA/NEMA, 50/60 Hz power circuit, 24 V AC/DC control voltage
  4. Display and Diagnostics: Integrated display with status indication for stopped, starting, stopping, at speed, alarm, and fault conditions
  5. Internal Bypass and Protection: Internal bypass reduces heat generation during run, with RC snubber DV/DT protection, 1400 V repetitive peak inverse voltage rating, and 6000 V rated impulse voltage per IEC
  6. Trip Classes and Short-Circuit Protection: Selectable trip classes 10, 15, 20, and 30 with trip current rating 117% of motor FLC, supported by standard fuse, circuit breaker, and Class CC/J/L time-delay devices up to 69 kA at 600 V
  7. Construction and Environment: Open-type enclosure with thermoset and thermoplastic control modules and plated brass, copper, or painted steel metal parts, operating temperature -5 to 50 °C, IP2X protection with terminal covers, 2000 m altitude, and 5 to 95% noncondensing humidity
150-F480NBRD

Product Information

Technical Specifications

Specifications for 150-F480NBRD

ParameterValue
Control Voltage24V AC/DC
Product FamilySMC Flex
With displayYes
Voltage type for actuatingAC/DC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz24 V
Rated control supply voltage at AC 60 Hz24 V
Overload current for line connected devices160 A
Overload current for delta connected devices277 A
Controller typeSoft starter
Control optionsBrake control
Trip classes10, 15, 20 and 30
Trip current rating117% of motor FLC
Transformer control module75VA @ 100...240V AC (-15%, +10%)
Heatsink fan rating60VA @ 110/120V AC or 220/240V AC
DV/DT protectionRC snubber network for power circuit
Repetitive peak inverse voltage rating1400V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz for power circuit
Line connected motor power, max600Hp @ 600V AC, 60 Hz, 3-phase
Delta connected motor power, max900Hp @ 575V AC, 60 Hz, 3-phase
Rated impulse voltage6000V per IEC for power circuit
Dielectric withstand2500V per IEC for power circuit
Line connected motor current160...480 A @ 600/Y/690V AC, 3-phase
Delta connected motor current277...831A @ 500/575V AC, 3-phase
Ampere tested european style, max9 URD 73xxx1250 6,6URD33xxx1250 @ 690V for maximum FLC
Ampere tested north american style, maxA070D33xxx1250 A100URD73xxx1250 @ 690V for maximum FLC
Transient protectionMetal oxide varistors: 220 J (optional) for power circuit
Insulation voltageRated 500V per IEC for power circuit
Rated operational voltage200...480V AC (-15%, +10%) per UL/CSA/NEMA for power circuit
Input OFF-state current<10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage
Short-circuit protection device listStandard fuse, circuit breaker and high capacity time delay class CC/J/L
Number of contacts1 for auxiliary contacts
High capacity available fault current, max69kA @ 600V, maximum current 800 A time delay Class J or Class L fuse for line connected motors
Type of currentAC for auxiliary contacts
Conventional thermal current (Ith)AC/DC: 5 A for auxiliary contacts
Type of control circuitElectromagnetic relay for auxiliary contacts
Type of contactsProgmable NO/NC for auxiliary contacts
Utilization categoryMG 1 per UL/CSA/NEMA for power circuit
Standard controller featureStatus indication: stopped, starting, stopping, at speed, alarm and fault
Standard available fault current, max70kA @ 690V for maximum FLC
Optional controller featureSMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motor’s full-load current rating
Rated control supply voltage at DC24 V
Integrated motor overload protectionYes
Short circuit protection device performance (SCPD) typeType 1
Number of sensors, max6 for PTC input ratings
ParameterValue
Inrush current control module5A @ 24V DC (-15%, +10%)
Voltage at PTC terminals (RPTC = open), max30V for PTC input ratings
Transient watts control module60 W @ 24V DC (-15%, +10%)
Steady state watts control module24 W @ 24V DC (-15%, +10%)
Voltage at PTC terminals (RPTC = 4 kΩ), max<7.5 for PTC input ratings
Response time800 ms for PTC input ratings
Inrush time control module250 ms @ 24V DC (-15%, +10%)
Transient time control module500 ms @ 24V DC (-15%, +10%)
Cold resistance of PTC sensor chain, max1500 ? for PTC input ratings
Tachometer input0...5V DC @ 4.5V DC = 100% Speed
Allen bradley power supply control module, min1606-XLP50E @ 24V DC (-15%, +10%)
Short circuit trip resistance25 ? ± 10 ? for PTC input ratings
Response resistance3400 ? ± 150 ? for PTC input ratings
Reset resistance1600 ? ± 100 ? for PTC input ratings
Input OFF-state voltage, max50V AC @ 10V DC/12V AC for control circuit
Input ON-state voltage, min85V AC @ 19.2V DC/20.4V AC for control circuit
Rated operational current3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts
Input ON-state current20mA @ 120V AC/40mA @ 240V AC, 7.6mA @ 24V AC/DC for control circuit
Contact typeAuxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4)
Steady state heat dissipation with control and fan power290 W
Storage and transportation temperature-20
Humidity5...95% (noncondensing)
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
Protection against electrical shockIP2X (with terminal covers) per IEC for power circuit
EMC emission levelsRadiated emission: Class A
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2
Altitude2000 m
Pollution degree2
Weight44.928
ShockOpsal: 5.5 G
Width290 mm (11.42 in)
Depth276.5 mm (10.89 in)
Height600 mm (23.62 in)
Power pole constructionHeatsink hockey puck thyristor modular design
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Make3600VA for auxiliary contacts
Break360VA for auxiliary contacts
Internal bypassYes
FunctionSingle direction
Power terminal markingsNEMA, CENELEC EN50 012
Control terminalsClAing yoke connection, M3 screw clA
Line/load side power terminalsTwo M12 x 1.75 diam holes per power pole
Number of poles3
EnclosureOpen type
Control modules constructionThermoset and thermoplastic moldings
Metal parts constructionPlated brass, copper or painted steel
RepairableREPAIRABLE
Preferred Availabilityfalse
Quick Turnaroundfalse
Dimension Height71.4
Lead Time22
Dimension Width41.605
Dimension Length40.589
Stock StatusNON_STOCKED
Weight UnitKG
Dimension UnitCM