Industrial Automation Parts. Prompt replies from real people.

ROCKWELL 150-F5NBR Smart Motor Controller

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ROCKWELL 150-F5NBR?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ROCKWELL 150-F5NBR cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
150-F5NBR
Material Number
—
Manufacturer
ROCKWELL
Product ID
105255

Get a Free Quote

Request pricing and availability for 150-F5NBR.

More parts to source? Send your whole list in one enquiry

Key specifications

Control Voltage
24V AC/DC
Rated operating voltage Ue
200
DV/DT protection
RC snubber network for power circuit
Operating frequency
50/60 Hz for power circuit
Rated operational current
3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts
Weight
6.5
See all specifications

Product Highlights

  1. Soft Starter: SMC Flex controller rated 5 A and 0.5-3.0 Hp at 460 V AC, with internal bypass and single-direction operation
  2. Motor Power Range: Line-connected up to 3 Hp at 575 V AC and delta-connected up to 7.5 Hp at 575 V AC, 60 Hz, 3-phase
  3. Voltage and Frequency: 200-480 V AC (-15%, +10%) operating voltage and 24 V AC/DC control voltage, 50/60 Hz
  4. Protection and Diagnostics: Integrated motor overload protection, trip classes 10, 15, 20 and 30, trip current 117% of motor FLC, and status indication for stopped, starting, stopping, at speed, alarm and fault
  5. Control and Auxiliary Contacts: Electromagnetic relay control circuit with programmable NO/NC auxiliary contacts rated 5 A AC/DC, 3 A at 120 V AC and 1.5 A at 240 V AC
  6. Terminal and Mounting Data: 3-pole open-type controller measuring 150 mm wide, 203 mm deep and 321 mm high, with power terminals accepting 0.8-2.5 mm2 (18-14 AWG) lower cables and 2.5-95 mm2 (14-3 AWG) upper line cables
150-F5NBR

Product Information

Technical Specifications

Specifications for 150-F5NBR

ParameterValue
Control Voltage24V AC/DC
Controller Rating5 A 0.5-3.0Hp @ 460V AC
Product FamilySMC Flex
With displayYes
Voltage type for actuatingAC/DC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz24 V
Rated control supply voltage at AC 60 Hz24 V
Overload current for line connected devices1 A
Overload current for delta connected devices1.7 A
Controller typeSoft starter
Control optionsNone
Trip classes10, 15, 20 and 30
Trip current rating117% of motor FLC
Transformer control module75VA @ 100...240V AC (-15%, +10%)
Heatsink fan rating20VA @ 110/120V AC or 220/240V AC
DV/DT protectionRC snubber network for power circuit
Repetitive peak inverse voltage rating1400V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz for power circuit
Line connected motor power, max3Hp @ 575V AC, 60 Hz, 3-phase
Delta connected motor power, max7.5Hp @ 575V AC, 60 Hz, 3-phase
Rated impulse voltage6000V per IEC for power circuit
Dielectric withstand2500V per IEC for power circuit
Line connected motor current1...5A @ 500/575V AC, 3-phase
Delta connected motor current1.7...8.7A @ 500/575V AC, 3-phase
Transient protectionMetal oxide varistors: 220 J (optional) for power circuit
Insulation voltageRated 500V per IEC for power circuit
Rated operational voltage200...480V AC (-15%, +10%) per UL/CSA/NEMA for power circuit
Input OFF-state current<10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage
Short-circuit protection device listStandard fuse, circuit breaker and high capacity time delay class CC/J/L
Number of contacts1 for auxiliary contacts
High capacity available fault current, max70kA @ 600V, maximum current 17.5 A time delay Class J or Class L fuse for inside delta connected motors
Type of currentAC for auxiliary contacts
Conventional thermal current (Ith)AC/DC: 5 A for auxiliary contacts
Type of control circuitElectromagnetic relay for auxiliary contacts
Type of contactsProgmable NO/NC for auxiliary contacts
Utilization categoryMG 1 per UL/CSA/NEMA for power circuit
Standard controller featureStatus indication: stopped, starting, stopping, at speed, alarm and fault
Standard available fault current, max5kA @ 200...600V, maximum standard fuse 35 A for delta device opsal current rating
Optional controller featureSMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motor’s full-load current rating
Rated control supply voltage at DC24 V
Integrated motor overload protectionYes
Short circuit protection device performance (SCPD) typeType 1
Number of sensors, max6 for PTC input ratings
Inrush current control module5A @ 24V DC (-15%, +10%)
Voltage at PTC terminals (RPTC = open), max30V for PTC input ratings
Transient watts control module60 W @ 24V DC (-15%, +10%)
ParameterValue
Steady state watts control module24 W @ 24V DC (-15%, +10%)
Voltage at PTC terminals (RPTC = 4 kΩ), max<7.5 for PTC input ratings
Response time800 ms for PTC input ratings
Inrush time control module250 ms @ 24V DC (-15%, +10%)
Transient time control module500 ms @ 24V DC (-15%, +10%)
Cold resistance of PTC sensor chain, max1500 ? for PTC input ratings
Tachometer input0...5V DC @ 4.5V DC = 100% Speed
Allen bradley power supply control module, min1606-XLP50E @ 24V DC (-15%, +10%)
Short circuit trip resistance25 ? ± 10 ? for PTC input ratings
Response resistance3400 ? ± 150 ? for PTC input ratings
Reset resistance1600 ? ± 100 ? for PTC input ratings
Input OFF-state voltage, max50V AC @ 10V DC/12V AC for control circuit
Input ON-state voltage, min85V AC @ 19.2V DC/20.4V AC for control circuit
Lower line side cable size0.8...2.5 mm2 (18...14 AWG) for power terminals
Lower load side cable size0.8...2.5 mm2 (18...14 AWG) for power terminals
Upper load side cable size2.5...50 mm2 (14...1 AWG) for load power terminals
Upper line side cable size2.5...95 mm2 (14...3 AWG) for line power terminals
Rated operational current3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts
Input ON-state current20mA @ 120V AC/40mA @ 240V AC, 7.6mA @ 24V AC/DC for control circuit
Contact typeAuxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4)
Steady state heat dissipation with control and fan power70
Storage and transportation temperature-20
Humidity5...95% (noncondensing)
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
Protection against electrical shockIP20 per IEC for power circuit
EMC emission levelsRadiated emission: Class A
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2
Altitude2000 m
Pollution degree2
Weight6.5
ShockOpsal: 15 G
Width150 mm (5.90 in)
Depth203 mm (8 in)
Height321 mm (12.60 in)
Power pole constructionHeatsink thyristor modular design
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Make3600VA for auxiliary contacts
Break360VA for auxiliary contacts
Tightening torque14.7 Nm (130 in-lb) for power terminals
Internal bypassYes
FunctionSingle direction
Power terminal markingsNEMA, CENELEC EN50 012
Control terminalsClAing yoke connection, M3 screw clA
Wire strip length18...20 mm (0.22...0.34 in) for power terminals
Number of poles3
EnclosureOpen type
Control modules constructionThermoset and thermoplastic moldings
Metal parts constructionPlated brass, copper or painted steel
RepairableREPAIRABLE
Preferred Availabilityfalse
Quick Turnaroundfalse
Dimension Height29.21
Lead Time5
Dimension Width18.11
Dimension Length40.589
Stock StatusNON_STOCKED
Weight UnitKG
Dimension UnitCM

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp