- 150-S317NUD
The Rockwell 150-S317NUD is a Smart Motor Controller in the SMC-50 series. It has a current rating of 317 A and a power rating of 300 hp at 575 V. The control module operates at 100-240 V AC. The controller is supplied in an open enclosure. It is repairable. Dimensions are 72.009 cm length, 41.001 cm width, and 42.009 cm height, with a weight of 45.359 kg. The unit is non-stocked and has a lead time of 10 days. Preferred availability and quick turnaround are not offered.
- 150-S361NUD
The Rockwell 150-S361NUD is a Smart Motor Controller in the SMC-50 configuration with bypass. It is rated 361 A and 350 hp at 575 V. Control voltage is 100-240V AC. Physical dimensions are 43.18 cm height, 45.72 cm width, and 78.74 cm length, with a weight of 47.627 KG. The unit is repairable. It is non-stocked, not preferred availability, and not quick turnaround, with a lead time of 20. This description is limited to the supplied parameters; no additional ratings, certifications, or application claims are stated.
- 150-S480NBD
The Rockwell 150-S480NBD is a Smart Motor Controller in the SMC-50 series. It is rated for 400 hp at 460V and operates on 100 V AC control. The unit is three-phase and supports 50/60 Hz. Physical dimensions are 42.037 cm height, 45.72 cm width, and 79.375 cm length, with a weight of 54.431 kg. The controller is repairable. It is not marked for preferred availability or quick turnaround. The 150-S480NBD is a stocked item with a lead time of 17.
- 150-SB4NBR
The Rockwell 150-SB4NBR is an SMC-50 smart motor controller with a 180 A controller rating and no display. It uses DC actuation at a rated operating voltage Ue of 200 V. Line-connected motor current is 60...180 A at 400/415/460 V AC, 3-phase; delta-connected motor current is 104...311 A at the same voltages. Overload current is 60 A for line-connected devices and 104 A for delta-connected devices. Trip classes are 5...30, with trip current rating 118% of motor FLC. Continuous duty power structure heat dissipation is 540 W. Base power draw from the control module with heat sink fan is 75 W at 24 V DC. Operating frequency is 47...63 Hz or DC for control power.
- 150-SCMD
The Rockwell 150-SCMD is a Smart Motor Controller supplied as an SMC-50 Control Module. The available reference text states that it supports 100-240V AC control power and includes two DC inputs and two relay outputs. No other electrical, mechanical, or performance ratings are provided in the supplied data. The reference text also describes monitoring, protection, and energy-saving functions, but these claims are not supported by structured parameters, so they are not restated here. No manufacturer part number or order code is supplied; the model is identified as 150-SCMD. Verify all specifications against the manufacturer's documentation before selection or installation.
- 150-SD1NBD
The Rockwell 150-SD1NBD is an SMC-50 smart motor controller rated 361 A with a D1 controller rating. It operates on 200 to 480 V AC, three-phase, at 47 to 63 Hz, with a control voltage of 100 to 240 V AC. Line-connected motor current is 120 to 361 A at 400/415/460 V AC; delta-connected motor current is 210 to 625 A at the same voltages. Integrated electronic I2t overload protection is included, with trip classes 5 to 30 and trip current at 118% of motor FLC. The open-type enclosure is IP00, with IP20 on control terminals only. Dimensions are 914.4 mm wide, 355.6 mm deep, and 1295.4 mm high. No display is provided.
- 150-SD3FBD-3-4R-6P-BP
The ROCKWELL 150-SD3FBD-3-4R-6P-BP is a smart motor controller rated 480 V AC and 520 A. It weighs 0.999 kg. The unit is not repairable and is non-stocked. Lead time is 22 days. Preferred availability and quick turnaround are not offered.
- 150-SD3FBD-3-4R-BP
The Rockwell 150-SD3FBD-3-4R-BP is a smart motor controller in the SMC-3 family. It operates at 480 V AC, with a listed current value of 120 V AC as supplied. The unit is non-repairable and non-stocked, with a lead time of 22 days and a weight of 0.999 KG. No dimensions are available; the supplied height, width, and length values are -1.0. The legacy description references diagnostics for phase reversal, phase loss, and phase imbalance, true 3-phase control, configurable auxiliary contacts, and selectable overload trip classes of 10, 15, 20, or OFF. These legacy claims are not confirmed by the structured parameters and should be verified against the manufacturer's documentation before use.