- 140G-G3C3-C40-KA-MT
The ROCKWELL 140G-G3C3-C40-KA-MT is a 3-pole motor protection circuit breaker with a 125 A frame size and a rated permanent current of 40 A. It uses a fixed thermal/fixed magnetic (TMF) trip unit, with a thermal trip current of 40 A and a magnetic trip current of 500 A. The device has a toggle control element, one auxiliary change-over contact, and no integrated undervoltage release or earth fault protection. Rated impulse withstand voltage is 8 kV, insulation voltage is rated 800 V per IEC, and watt loss is 7.8 W. Interrupting ratings include 65 kA at 240 V, 50/60 Hz per NEMA, UL, and CSA, and IEC 60947-2 Icu of 85 kA at 220...230 V AC, 50/60 Hz.
- 140G-G3C3-C50-KJ
The Rockwell 140G-G3C3-C50-KJ is a 3-pole motor protection circuit breaker with a 125 A frame size and a rated permanent current of 50 A. It uses a toggle control element and a fixed thermal/fixed magnetic (TMF) protection unit, with a thermal trip current of 50 A and a magnetic trip current of 500 A. The thermal trip rating is 50 A at an ambient temperature of 40 °C. Interrupting ratings include 65 kA at 240 V, 50/60 Hz per NEMA, UL, and CSA, and an IEC 60947-2 Icu of 85 kA at 220 to 230 V AC, 50/60 Hz. Rated impulse withstand voltage is 8 kV, and insulation voltage is rated 800 V per IEC.
- 140G-G3C3-C50-KJ-MB
The Rockwell 140G-G3C3-C50-KJ-MB is a 3-pole motor protection circuit breaker with a 125 frame size and a rated permanent current of 50 A. It uses fixed thermal and fixed magnetic TMF construction, with a thermal trip current of 50 A and magnetic trip current of 500 A. Interrupting rating is 65 kA at 240 V, 50/60 Hz per NEMA, UL, and CSA. Per IEC 60947-2, rated ultimate short-circuit breaking capacity is 85 kA at 220...230 V AC, 50/60 Hz, and rated service short-circuit breaking capacity is 75% Icu at 220...230 V AC, 50/60 Hz. It has one change-over auxiliary contact, a toggle control element, and no integrated undervoltage release or earth fault protection.
- 140G-G3C3-C60
The Rockwell 140G-G3C3-C60 is a 3-pole molded case circuit breaker with thermal-magnetic protection and a rated current of 125 A. Its IEC breaking capacity is 50 kA at 415 V. The unit is not repairable. Dimensions are 13.21 cm height, 14.61 cm width, and 13.31 cm length, with a weight of 1.163 kg. The product is stocked; preferred availability and quick turnaround are both false, and lead time is 5. No manufacturer part number or order code is supplied. The legacy description's 35 kA at 480 V AC interrupting capacity conflicts with the authoritative IEC rating and is omitted.
- 140G-G3C3-C63
Rockwell motor protection circuit breaker, display model 140G-G3C3-C63. It is a 3-pole device with fixed thermal and fixed magnetic adjustment. Load rating is 63A; a separate current parameter lists 125 A. Standards compliance is UL489, CSA22.2 No. 5, and IEC 60947-2. The breaker is not repairable. Dimensions are 13.97 cm height, 13.97 cm width, and 13.97 cm length; weight is 1.361 kg. Stock status is non-stocked, preferred availability is false, and quick turnaround is false, with a lead time of 5.
- 140G-G3C3-C63-KJ
Product identification: ROCKWELL 140G-G3C3-C63-KJ. The Allen-Bradley 140G-G3C3-C63-KJ is a three-pole motor protection circuit breaker rated 125.0 A with a 35 kA interrupt rating. It uses thermal and magnetic trip mechanisms. Dimensions are 9.398 cm high, 12.954 cm wide, and 13.716 cm long; weight is 1.22 kg. The device is not repairable.
- 140G-G3C3-C80
Product identification: ROCKWELL 140G-G3C3-C80. The Allen-Bradley 140G-G3C3-C80 is a motor protection circuit breaker with thermal magnetic protection and a 125 A frame. It is not repairable. Dimensions are 13.21 mm high, 12.9 mm wide, and 15.09 mm long, with a weight of 1.168 kg.
- 140G-G3C3-C80-BA-MT
The Rockwell 140G-G3C3-C80-BA-MT is a three-pole motor protection circuit breaker with a 125 A frame and an 80 A rated permanent current. It uses a toggle control element and a fixed thermal/fixed magnetic (TMF) protection unit, with a thermal trip current of 80 A and a magnetic trip current of 800 A. Rated impulse withstand voltage is 8 kV, and insulation voltage is rated 800 V per IEC. Interrupting ratings include 65 kA at 240 V, 50/60 Hz per NEMA, UL, and CSA, and IEC 60947-2 Icu of 85 kA at 220 to 230 V AC, 50/60 Hz. It has two change-over auxiliary contacts, no integrated undervoltage release, and no integrated earth fault protection.