- 140G-G3C3-C63-KJ
Product identification: ROCKWELL 140G-G3C3-C63-KJ. The Allen-Bradley 140G-G3C3-C63-KJ is a three-pole motor protection circuit breaker rated 125.0 A with a 35 kA interrupt rating. It uses thermal and magnetic trip mechanisms. Dimensions are 9.398 cm high, 12.954 cm wide, and 13.716 cm long; weight is 1.22 kg. The device is not repairable.
- 140G-G3C3-C80
Product identification: ROCKWELL 140G-G3C3-C80. The Allen-Bradley 140G-G3C3-C80 is a motor protection circuit breaker with thermal magnetic protection and a 125 A frame. It is not repairable. Dimensions are 13.21 mm high, 12.9 mm wide, and 15.09 mm long, with a weight of 1.168 kg.
- 140G-G3C3-C80-BA-MT
The Rockwell 140G-G3C3-C80-BA-MT is a three-pole motor protection circuit breaker with a 125 A frame and an 80 A rated permanent current. It uses a toggle control element and a fixed thermal/fixed magnetic (TMF) protection unit, with a thermal trip current of 80 A and a magnetic trip current of 800 A. Rated impulse withstand voltage is 8 kV, and insulation voltage is rated 800 V per IEC. Interrupting ratings include 65 kA at 240 V, 50/60 Hz per NEMA, UL, and CSA, and IEC 60947-2 Icu of 85 kA at 220 to 230 V AC, 50/60 Hz. It has two change-over auxiliary contacts, no integrated undervoltage release, and no integrated earth fault protection.
- 140G-G3C3-C80-KA-MT
The Rockwell 140G-G3C3-C80-KA-MT is a three-pole thermal magnetic molded case circuit breaker with a rated permanent current Iu of 80 A and a frame size of 125 A. Thermal trip current is fixed at 80 A, and magnetic trip current is 800 A. It provides one auxiliary change-over contact and uses a toggle control element. Rated impulse withstand voltage Uimp is 8 kV, insulation voltage Ui is rated 800 V per IEC, and watt loss is 14.4 W. Interrupting ratings include 65 kA at 240 V, 50/60 Hz per NEMA, UL, and CSA, and IEC 60947-2 Icu of 85 kA at 220 to 230 V AC, 50/60 Hz. Dimensions are 76.2 mm wide, 130 mm high, and 70 mm deep, with IP40 protection and screw main-circuit connections.
- 140G-G3C3-C90
The Rockwell 140G-G3C3-C90 is a motor protection circuit breaker with a fixed thermal and fixed magnetic adjustment type. Its current rating is 125 A. The breaker is not repairable. Dimensions are 13.31 cm height, 12.8 cm width, and 15.01 cm length, with a weight of 1.166 kg. It is non-stocked and not preferred for availability, with a lead time of 5. No certifications, standards, or application claims are supplied for this model.
- 140G-G3C3-C90-KJ
The Rockwell 140G-G3C3-C90-KJ is a three-pole motor protection circuit breaker with a fixed thermal and fixed magnetic (TMF) trip unit. Rated permanent current Iu is 90 A, with a fixed thermal trip current of 90 A and magnetic trip current of 900 A. It is a complete built-in device with a toggle control element and screw-type front connections. Interrupting rating is 65 kA at 240 V, 50/60 Hz per NEMA, UL, and CSA. Rated ultimate short-circuit breaking capacity is 85 kA at 220 to 230 V AC, 50/60 Hz per IEC 60947-2. Electrical life is 8000 operations at 415 V AC; mechanical life is 25000 operations. Degree of protection is IP40. It is not repairable.
- 140G-G3C3-D10
The Rockwell 140G-G3C3-D10 is a three-pole molded case circuit breaker with a 100 A load rating and thermal magnetic protection using fixed thermal and fixed magnetic adjustment. Its IEC breaking capacity is 50 kA at 415 V, and its UL interrupting rating is 35 kA at 480 V. The unit is not repairable. Dimensions are 13.487 cm high, 12.802 cm wide, and 14.808 cm long, with a weight of 1.186 kg. It is listed as stocked and preferred availability, with a lead time of 5.
- 140G-G3C3-D10-SJ-AJ
The ROCKWELL 140G-G3C3-D10-SJ-AJ is a three-pole motor protection circuit breaker with a 125 A frame and a rated permanent current of 100 A. It uses fixed thermal and fixed magnetic (TMF) protection, with a thermal trip current of 100 A and a magnetic trip current of 1000 A. The toggle-operated device has one change-over auxiliary contact and no integrated undervoltage release or earth fault protection. Rated impulse withstand voltage is 8 kV, insulation voltage is 800 V per IEC, and thermal loss is 21.0 W. Interrupting ratings include 65 kA at 240 V, 50/60 Hz per NEMA, UL, and CSA, and IEC 60947-2 Icu of 85 kA at 220 to 230 V AC, 50/60 Hz.