- 150-F85NBDD
The Rockwell 150-F85NBDD is an SMC Flex soft starter with an 85 A controller rating (15–60 Hp at 460 V AC) and an integrated display. It operates from a 200...480 V AC power circuit (-15%, +10%) per UL/CSA/NEMA at 50/60 Hz, with control voltage of 100...240 V AC. Line-connected motor current is 17...85 A at 500/575 V AC, three-phase; delta-connected current is 29.4...147 A. Overload current is 17 A line-connected and 29.4 A delta-connected, with trip current at 117% of motor FLC and selectable trip classes 10, 15, 20, and 30. Integrated motor overload protection is included, along with an internal bypass, three poles, and a heatsink thyristor modular power pole design. The open-type enclosure measures 150 mm wide, 203 mm deep, and 321 mm high.
- 150-F85NBRB
The Rockwell 150-F85NBRB is an SMC Flex soft starter rated 85 A and 15–60 Hp at 460 V AC. It operates on 24 V AC/DC control voltage and provides 200–480 V AC (-15%, +10%) rated operational voltage per UL/CSA/NEMA for the power circuit, with 50/60 Hz operating frequency. Line-connected motor current is 17–85 A at 500/575 V AC, three-phase; delta-connected motor current is 29.4–147 A at 500/575 V AC, three-phase. Integrated motor overload protection is included, with trip classes 10, 15, 20 and 30 and trip current rating 117% of motor FLC. The controller has an open-type enclosure, IP20 protection per IEC for the power circuit, an internal bypass, and a display.
- 150-F85NBRD
The Rockwell 150-F85NBRD is an SMC Flex soft starter with an 85 A controller rating and 15–60 Hp at 460 V AC. It operates at 200 V rated operating voltage and 50/60 Hz for the power circuit, with 24 V AC/DC control voltage and 24 V AC control supply at both 50 Hz and 60 Hz. Overload current is 17 A for line-connected devices and 29.4 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. The unit includes a display, brake control, and an RC snubber network for power-circuit DV/DT protection. Maximum line-connected motor power is 75 Hp at 575 V AC, 60 Hz, three-phase.
- 150-F85NCD
The Rockwell 150-F85NCD is an SMC Flex soft starter with an 85 A controller rating for 15–60 Hp motors at 460V AC. It operates from a 100...240V AC control supply at 50/60 Hz and includes a display. The power circuit uses an RC snubber network for DV/DT protection and has a repetitive peak inverse voltage rating of 1600V per UL/CSA/NEMA. Trip classes are 10, 15, 20, and 30, with a trip current rating of 117% of motor FLC. Overload current is 17 A for line-connected devices and 29.4 A for delta-connected devices. The transformer control module is rated 75VA at 100...240V AC (-15%, +10%). Maximum line-connected motor power is 75Hp at 575V AC, 60 Hz, three-phase.
- 150-F85NCRB
The Rockwell 150-F85NCRB is an SMC Flex soft starter with an integrated display and pump control option. It is rated 85 A and 15–60 HP at 460 V AC, with a 24 V AC/DC control supply voltage at both 50 Hz and 60 Hz, and 24 V DC. Power circuit operating frequency is 50/60 Hz, rated operational voltage is 200–600 V AC (-15%, +10%) per UL/CSA/NEMA, and rated impulse voltage is 6000 V per IEC. Line-connected motor current is 17–85 A at 500/575 V AC, three-phase; delta-connected motor current is 29.4–147 A at 500/575 V AC, three-phase. Trip classes are 10, 15, 20, and 30. The open-type enclosure is IP20 per IEC, three poles, with internal bypass.
- 150-F86
Product identification: ROCKWELL 150-F86. The Allen-Bradley 150-F86 is a smart motor controller rated 600 V and 5 A. It is not repairable and is non-stocked. Dimensions are 5.999 in height, 5.999 in width, and 15.001 in length, with a weight of 0.185 kg.
- 150-F970NBAD
The Rockwell 150-F970NBAD is a soft starter smart motor controller with integral bypass and an open-type enclosure. It is rated 970 A and 800 Hp at 460V AC, 60 Hz, 3-phase for line-connected motors, and 800 kW at 500V AC, 50 Hz, 3-phase for delta-connected motors. Control voltage is 230...240V AC, with rated control supply voltage of 230 V at both 50 Hz and 60 Hz. A multilingual LCD display is included. Overload current is 323 A for line-connected devices and 400 A for delta-connected devices. Trip classes are 10, 15, 20 and 30, with trip current rating at 117% of motor full-load current. The controller measures 596.9 mm wide, 346.2 mm deep, and 1041.1 mm high.
- 150-F970NCA
The Rockwell 150-F970NCA is a three-phase soft starter with a 970 A controller rating and 800 Hp at 460 V AC, 60 Hz. It accepts rated operational voltage of 200...600 V AC (-15%, +10%) per UL/CSA/NEMA and control voltage of 230...240 V AC. The open-type device includes an internal bypass, integrated motor overload protection, and a display. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. Line-connected motor current is 323...970 A at 600/Y/690 V AC; delta-connected motor current is 400...1200 A at 500/575 V AC. Operating temperature is -5 to 50 degrees C for open devices. Dimensions are 596.9 mm wide, 346.2 mm deep, and 1041.1 mm high.