Industrial Automation Parts. Prompt replies from real people.

ROCKWELL 150-F970NBAD SMC Flex Smart Motor Controller

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ROCKWELL 150-F970NBAD?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ROCKWELL 150-F970NBAD cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
150-F970NBAD
Material Number
—
Manufacturer
ROCKWELL
Product ID
107311

Get a Free Quote

Request pricing and availability for 150-F970NBAD.

More parts to source? Send your whole list in one enquiry

Key specifications

Control Voltage
230...240V AC
Rated operating voltage Ue
200
DV/DT protection
RC snubber network for power circuit
Operating frequency
50/60 Hz for power circuit
Rated operational current
3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts
Weight
193.23
See all specifications

Product Highlights

  1. Controller Type and Rating: Soft starter rated 970 A and 800 Hp at 460 V AC, 60 Hz, 3-phase for line-connected motors
  2. Motor Connection Options: Line-connected current 323...970 A at 600/Y/690 V AC and delta-connected current 400...1200 A at 500/575 V AC, 3-phase
  3. Control Voltage and Frequency: 230...240 V AC control supply at 50/60 Hz with AC actuation
  4. Integrated Bypass and Protection: Internal bypass plus current and voltage protection, with integrated motor overload protection
  5. Display and Adjustable Settings: Multilingual LCD display with programmable parameters including trip classes 10, 15, 20 and 30 and trip current rating 117% of motor FLC
  6. Braking Control: Optional SMB smart motor braking provides motor braking without additional equipment, with braking current adjustable from 0...400% of motor full-load current
  7. Fault Current Withstand: Standard available fault current up to 85 kA at 690 V and high-capacity available fault current up to 85 kA at 600 V with Class J or L time-delay fuses for inside-delta connected motors
  8. Operating Conditions: Open-type device operating from -5 to 50 °C at altitudes up to 2000 m and humidity 5...95% noncondensing
150-F970NBAD

Product Information

Technical Specifications

Specifications for 150-F970NBAD

ParameterValue
Control Voltage230...240V AC
Controller Rating970 A 800Hp @ 460V AC
With displayYes
Voltage type for actuatingAC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz230 V
Rated control supply voltage at AC 60 Hz230 V
Overload current for line connected devices323 A
Overload current for delta connected devices400 A
Controller typeSoft starter
Control optionsBrake control
Trip classes10, 15, 20 and 30
Trip current rating117% of motor FLC
Heatsink fan rating150VA @ 110/120V AC or 220/240V AC
DV/DT protectionRC snubber network for power circuit
Repetitive peak inverse voltage rating1400V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz for power circuit
Line connected motor power, max800Hp @ 460V AC, 60 Hz, 3-phase
Delta connected motor power, max800 kW @ 500V AC @ 50Hz, 3-phase
Rated impulse voltage6000V per IEC for power circuit
Dielectric withstand2500V per IEC for power circuit
Line connected motor current323...970 A @ 600/Y/690V AC, 3-phase
Delta connected motor current400...1200A @ 500/575V AC, 3-phase
Ampere tested european style, maxTwo fuses in parallel 6,6URD33xxx1250 @ 690V for maximum FLC
Ampere tested north american style, maxTwo fuses in parallel A070URD33xxx1250 @ 690V for maximum FLC
Transient protectionMetal oxide varistors: 220 J (optional) for power circuit
Insulation voltageRated 500V per IEC for power circuit
Rated operational voltage200...480V AC (-15%, +10%) per UL/CSA/NEMA for power circuit
Input OFF-state current<10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage
Short-circuit protection device listStandard fuse, circuit breaker and high capacity time delay class CC/J/L
Number of contacts1 for auxiliary contacts
High capacity available fault current, max85kA @ 600V, maximum current 3000 A time delay Class J or Class L fuse for inside delta connected motors
Type of currentAC for auxiliary contacts
Conventional thermal current (Ith)AC/DC: 5 A for auxiliary contacts
Type of control circuitElectromagnetic relay for auxiliary contacts
Type of contactsProgmable NO/NC for auxiliary contacts
Utilization categoryMG 1 per UL/CSA/NEMA for power circuit
Standard controller featureStatus indication: stopped, starting, stopping, at speed, alarm and fault
Standard available fault current, max85kA @ 690V for maximum FLC
Optional controller featureSMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motor’s full-load current rating
Integrated motor overload protectionYes
ParameterValue
Short circuit protection device performance (SCPD) typeType 1
Number of sensors, max6 for PTC input ratings
Voltage at PTC terminals (RPTC = open), max30V for PTC input ratings
Voltage at PTC terminals (RPTC = 4 kΩ), max<7.5 for PTC input ratings
Transformer rating control module751 VA (recommended 800 VA)
Response time800 ms for PTC input ratings
Cold resistance of PTC sensor chain, max1500 ? for PTC input ratings
Tachometer input0...5V DC @ 4.5V DC = 100% Speed
Short circuit trip resistance25 ? ± 10 ? for PTC input ratings
Response resistance3400 ? ± 150 ? for PTC input ratings
Reset resistance1600 ? ± 100 ? for PTC input ratings
Input OFF-state voltage, max50V AC @ 10V DC/12V AC for control circuit
Input ON-state voltage, min85V AC @ 19.2V DC/20.4V AC for control circuit
Rated operational current3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts
Input ON-state current20mA @ 120V AC/40mA @ 240V AC, 7.6mA @ 24V AC/DC for control circuit
Contact typeAuxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4)
Steady state heat dissipation with control and fan power812 W
Storage and transportation temperature-20
Humidity5...95% (noncondensing)
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
Protection against electrical shockIP00 (open device) per IEC for power circuit
EMC emission levelsRadiated emission: Class A
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2
Altitude2000 m
Pollution degree2
Weight193.23
ShockOpsal: 4 G
Width596.9 mm (23.50 in)
Depth346.2 mm (13.63 in)
Height1041.1 mm (41 in)
Power pole constructionHeatsink hockey puck thyristor modular design
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Make3600VA for auxiliary contacts
Break360VA for auxiliary contacts
Internal bypassYes
FunctionSingle direction
Power terminal markingsNEMA, CENELEC EN50 012
Control terminalsClAing yoke connection, M3 screw clA
Line/load side power terminalsTwo 13.5 mm (0.53 in) diam holes per power pole
Number of poles3
EnclosureOpen type
Control modules constructionThermoset and thermoplastic moldings
Metal parts constructionPlated brass, copper or painted steel
RepairableREPAIRABLE
Preferred Availabilityfalse
Quick Turnaroundfalse
Dimension Height63.5
Lead Time20
Dimension Width76.2
Dimension Length126.899
Stock StatusNON_STOCKED
Weight UnitKG
Dimension UnitCM

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp