- 140G-G-UVC
Product identification: ROCKWELL 140G-G-UVC. The Allen Bradley 140G-G-UVC is a motor protection circuit breaker accessory. It is not repairable. Dimensions are 5.715 cm height, 10.287 cm width, and 13.462 cm length, with a weight of 0.152 kg. The undervoltage release automatically trips the circuit breaker when voltage drops. It is certified for global use.
- 140G-G-UVD
The Rockwell 140G-G-UVD is a circuit-breaker accessory undervoltage release unit for motor protection circuit breakers. It is not repairable. Dimensions are 13.11 cm length, 10.8 cm width, and 5.51 cm height, with a weight of 0.12 kg.
- 140G-G-UVJ
The Rockwell 140G-G-UVJ is an under voltage relay accessory for circuit breakers. It is not repairable. Dimensions are 5.499 cm high, 13.5 cm wide, and 11.001 cm long, with a weight of 0.14 kg. The product is non-stocked, has a lead time of 42 days, and is not preferred for availability or quick turnaround. No voltage range, compatibility, or certification details are provided in the authoritative data.
- 140G-G-UVKY
The Rockwell 140G-G-UVKY is a motor protection circuit breaker with UL Listed, CSA Certified, and CE markings. It protects circuits against overload and short circuits. Dimensions are 6.0 cm height, 11.0 cm width, and 14.0 cm length, with a weight of 0.12 kg. The unit is not repairable.
- 140G-G-UVY
The Rockwell 140G-G-UVY is a motor protection circuit breaker accessory. It is UL Listed, CSA Certified, and CE marked. Dimensions are 6.0 height, 11.0 width, and 14.0 length, with a weight of 0.12 kg. The unit is not repairable.
- 140G-G2C3-C15
The Rockwell 140G-G2C3-C15 is a motor protection circuit breaker with an IEC breaking capacity of 36kA at 415V and a UL interrupting rating of 25kA at 480V. It is not repairable. Dimensions are 12.8 mm height, 15.39 mm width, and 14.1 mm length, with a weight of 1.179 kg. It is designed for panel mounting.
- 140G-G2C3-C30-AJ
The Rockwell 140G-G2C3-C30-AJ is a 3-pole motor protection circuit breaker with a 125 A frame and 30 A rated permanent current. Thermal trip current is fixed at 30 A; magnetic trip current is 500 A. Construction is T/M-fixed thermal/fixed magnetic TMF with a toggle control element and screw front-side main circuit connections. Rated impulse withstand voltage is 8 kV; insulation voltage is rated 800 V per IEC. Interrupting rating is 50 kA at 240 V, 50/60 Hz per NEMA, UL, and CSA. IEC 60947-2 rated ultimate short-circuit breaking capacity is 65 kA at 220 to 230 V AC, 50/60 Hz. Thermal trip rating is 30 A at 40 °C ambient. Degree of protection is IP40. Dimensions are 76.2 mm width, 130 mm height, and 70 mm depth.
- 140G-G2C3-C35-UJ
Product identification: ROCKWELL 140G-G2C3-C35-UJ. The Allen-Bradley 140G-G2C3-C35-UJ is a 3-pole motor protection circuit breaker with a 125 frame size and a rated permanent current of 35 A. It uses a thermal-magnetic, fixed thermal/fixed magnetic (TMF) construction, with a thermal trip current of 35 A and a magnetic trip current of 500 A. The toggle-operated device includes an integrated undervoltage release and does not include integrated earth fault protection or a motor drive. Rated impulse withstand voltage is 8 kV, and rated insulation voltage is 800 V per IEC. Maximum reverse-fed voltage is 690 V AC per IEC. Interrupting ratings include 50 kA at 240 V, 50/60 Hz per NEMA, UL, and CSA, and IEC 60947-2 Icu of 65 kA at 220 to 230 V AC, 50/60 Hz. Electrical life is 8000 cycles at 415 V AC. Thermal loss is 6.0 W.