- 150-F85FHD-1-6P
The ROCKWELL 150-F85FHD-1-6P is a smart motor controller supplied in a NEMA Type 4/12 (IP65) enclosure. It operates at 208 V AC. The unit is not repairable. Weight is 0.999 KG.
- 150-F85NBD
Product identification: ROCKWELL 150-F85NBD. The Allen-Bradley 150-F85NBD is an SMC Flex soft starter with an 85 A controller rating for 15–60 Hp at 460 V AC. It operates from a 100...240 V AC control supply at 50/60 Hz and includes a display. The power circuit is rated for 50/60 Hz operation, with a repetitive peak inverse voltage rating of 1400 V per UL/CSA/NEMA and DV/DT protection via an RC snubber network. Overload current is 17 A for line-connected devices and 29.4 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. Maximum line-connected motor power is 75 Hp at 575 V AC, 60 Hz, three-phase. Control options are none.
- 150-F85NBDD
The Rockwell 150-F85NBDD is an SMC Flex soft starter with an 85 A controller rating (15–60 Hp at 460 V AC) and an integrated display. It operates from a 200...480 V AC power circuit (-15%, +10%) per UL/CSA/NEMA at 50/60 Hz, with control voltage of 100...240 V AC. Line-connected motor current is 17...85 A at 500/575 V AC, three-phase; delta-connected current is 29.4...147 A. Overload current is 17 A line-connected and 29.4 A delta-connected, with trip current at 117% of motor FLC and selectable trip classes 10, 15, 20, and 30. Integrated motor overload protection is included, along with an internal bypass, three poles, and a heatsink thyristor modular power pole design. The open-type enclosure measures 150 mm wide, 203 mm deep, and 321 mm high.
- 150-F85NBRB
The Rockwell 150-F85NBRB is an SMC Flex soft starter rated 85 A and 15–60 Hp at 460 V AC. It operates on 24 V AC/DC control voltage and provides 200–480 V AC (-15%, +10%) rated operational voltage per UL/CSA/NEMA for the power circuit, with 50/60 Hz operating frequency. Line-connected motor current is 17–85 A at 500/575 V AC, three-phase; delta-connected motor current is 29.4–147 A at 500/575 V AC, three-phase. Integrated motor overload protection is included, with trip classes 10, 15, 20 and 30 and trip current rating 117% of motor FLC. The controller has an open-type enclosure, IP20 protection per IEC for the power circuit, an internal bypass, and a display.
- 150-F85NBRD
The Rockwell 150-F85NBRD is an SMC Flex soft starter with an 85 A controller rating and 15–60 Hp at 460 V AC. It operates at 200 V rated operating voltage and 50/60 Hz for the power circuit, with 24 V AC/DC control voltage and 24 V AC control supply at both 50 Hz and 60 Hz. Overload current is 17 A for line-connected devices and 29.4 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. The unit includes a display, brake control, and an RC snubber network for power-circuit DV/DT protection. Maximum line-connected motor power is 75 Hp at 575 V AC, 60 Hz, three-phase.
- 150-F85NCD
The Rockwell 150-F85NCD is an SMC Flex soft starter with an 85 A controller rating for 15–60 Hp motors at 460V AC. It operates from a 100...240V AC control supply at 50/60 Hz and includes a display. The power circuit uses an RC snubber network for DV/DT protection and has a repetitive peak inverse voltage rating of 1600V per UL/CSA/NEMA. Trip classes are 10, 15, 20, and 30, with a trip current rating of 117% of motor FLC. Overload current is 17 A for line-connected devices and 29.4 A for delta-connected devices. The transformer control module is rated 75VA at 100...240V AC (-15%, +10%). Maximum line-connected motor power is 75Hp at 575V AC, 60 Hz, three-phase.
- 150-F85NCRB
The Rockwell 150-F85NCRB is an SMC Flex soft starter with an integrated display and pump control option. It is rated 85 A and 15–60 HP at 460 V AC, with a 24 V AC/DC control supply voltage at both 50 Hz and 60 Hz, and 24 V DC. Power circuit operating frequency is 50/60 Hz, rated operational voltage is 200–600 V AC (-15%, +10%) per UL/CSA/NEMA, and rated impulse voltage is 6000 V per IEC. Line-connected motor current is 17–85 A at 500/575 V AC, three-phase; delta-connected motor current is 29.4–147 A at 500/575 V AC, three-phase. Trip classes are 10, 15, 20, and 30. The open-type enclosure is IP20 per IEC, three poles, with internal bypass.
- 150-F86
Product identification: ROCKWELL 150-F86. The Allen-Bradley 150-F86 is a smart motor controller rated 600 V and 5 A. It is not repairable and is non-stocked. Dimensions are 5.999 in height, 5.999 in width, and 15.001 in length, with a weight of 0.185 kg.