- 150-C16FCD-3-4R-6P-901
The Rockwell 150-C16FCD-3-4R-6P-901 is a smart motor controller rated 16 A at 600 V AC. It is designated not repairable. The unit weighs 0.999 kg. Dimensions are not specified. The product is non-stocked and not preferred for availability, with a lead time of 29. No repairability service is indicated. The model number is 150-C16FCD-3-4R-6P-901. No other ratings, certifications, or applications are stated.
- 150-C16FCD-6P
Product identification: ROCKWELL 150-C16FCD-6P. The Allen Bradley 150-C16FCD-6P is a smart motor controller rated 600 V AC and 16 A. It is supplied as a non-repairable unit. The controller weighs 0.999 kg. It is not a stocked item and is not preferred for availability or quick turnaround.
- 150-C16FHD
The ROCKWELL 150-C16FHD is a smart motor controller rated 16 A at 208 V AC. It provides overload, phase imbalance, and overheating protection. The unit is non-repairable and non-stocked, with a lead time of 22 days. Weight is 0.999 kg.
- 150-C16NBD
The Rockwell 150-C16NBD is an SMC-3 series smart motor controller for 3-phase power circuits, open type, single direction, with internal bypass and integrated motor overload protection. Line-connected motor current is 5.3 to 16 A at 380/400/415/460 V AC, 3-phase; delta-connected motor current is 9.1 to 27.6 A at the same voltages. Maximum line-connected motor power is 7.5 kW at 380/400/415 V AC, 50 Hz, 3-phase. Selectable overload trip class is 10, 15, or 20, with selectable start times of 2, 5, 10, 15, 20, 25, or 30 s and selectable current limit of 150%, 250%, 350%, or 450% of full load current. Dimensions are 44.8 mm wide, 110 mm deep, and 139.7 mm high. Degree of protection is IP2X.
- 150-C16NCD
The Rockwell 150-C16NCD is an SMC-3 smart motor controller without a display. It operates on AC/DC control voltage, with rated control supply voltage of 100 V at both 50 Hz and 60 Hz. The rated operating voltage is 200 V. For line-connected three-phase motors, it supports 5.3 to 16 A at 500/575 V AC and up to 7.5 kW at 500 V AC, 50 Hz. Delta-connected ratings are 9.1 to 27.6 A and 7.5 to 20 hp at 575 V AC, 60 Hz. Power-circuit specifications include 1000 V/µs dv/dt protection, 1600 V repetitive peak voltage per UL/CSA/NEMA, 6 kV rated impulse voltage, and 2500 V AC dielectric withstand per IEC. Rated insulation is 600 V AC per UL/CSA/NEMA.
- 150-C16NCR
The Rockwell Allen-Bradley 150-C16NCR is an SMC-3 smart motor controller for three-phase motor control. It operates at a rated operating voltage Ue of 200 and accepts a rated control supply voltage of 24 at both 50 Hz and 60 Hz, with AC/DC actuation. The power circuit is rated for 50/60 Hz per UL/CSA/NEMA, with 1000 V/µs dv/dt protection, 1600 V repetitive peak voltage per UL/CSA/NEMA, 6 kV rated impulse voltage, and 2500 V AC dielectric withstand per IEC. Line-connected motor current is 5.3 to 16 A at 500/575 V AC, three-phase, with maximum line-connected motor power of 7.5 kW at 500 V AC, 50 Hz, three-phase. No display is included.
- 150-C19NBD-NC
The Rockwell 150-C19NBD-NC is a smart motor controller in the Allen Bradley 150 series. It is a soft starter controller with soft stop, integrated motor overload protection, and selectable start times of 2, 5, 10, 15, 20, 25, or 30 seconds. It provides Type 1 short circuit protection and selectable overload trip classes of 10, 15, or 20. The unit is rated 200.0 V AC. It is not repairable. Dimensions are 9.296 cm height, 17.501 cm width, and 18.39 cm length; weight is 0.894 kg. Stock status is non-stocked, preferred availability is false, and quick turnaround is false.
- 150-C19NBR
The Rockwell Allen-Bradley 150-C19NBR is an SMC-3 smart motor controller without a display. It operates at a rated voltage of 200 and accepts 24 V AC control supply at both 50 Hz and 60 Hz. The controller supports line-connected motor current of 6.3 to 19 A at 380/400/415/460 V AC, three-phase, and delta-connected motor current of 10.9 to 32.8 A at the same voltages. Maximum line-connected motor power is 7.5 kW at 380/400/415 V AC, 50 Hz, three-phase. Overload current is 6.3 A. The power circuit has 1000 V/µs DV/DT protection, 1400 V repetitive peak voltage per UL/CSA/NEMA, 6 kV rated impulse voltage, and 2500 V AC dielectric withstand per IEC.