Industrial Automation Parts. Prompt replies from real people.

ROCKWELL 150-C16NCD Smart Motor Controller

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/24/2026

Q1Can you supply the ROCKWELL 150-C16NCD?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ROCKWELL 150-C16NCD cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
150-C16NCD
Material Number
—
Manufacturer
ROCKWELL
Product ID
106577

Get a Free Quote

Request pricing and availability for 150-C16NCD.

More parts to source? Send your whole list in one enquiry

Key specifications

Voltage type for actuating
AC/DC
Rated operating voltage Ue
200
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit
Rated control power during start with fan
215mA @ 120V AC/180mA @ 240V AC, 800mA @ 24V DC/660mA @ 24V AC
Rated operational current, max
TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Weight
0.905
See all specifications

Product Highlights

  1. Soft Start and Stop: Standard soft stop plus selectable start times of 2, 5, 10, 15, 20, 25, or 30 s and selectable soft stop at Off, 100%, 200%, or 300% of the start time setting when wired
  2. Motor Protection: Integrated motor overload protection with selectable trip class 10, 15, or 20 and selectable current limit of 150%, 250%, 350%, or 450% of full load current
  3. Power Ratings: Line connected motor current 5.3...16 A at 500/575 V AC 3-phase with maximum 7.5 kW at 500 V AC 50 Hz, delta connected motor current 9.1...27.6 A with maximum 7.5...20 hp at 575 V AC 60 Hz
  4. Starting Control: Selectable initial torque of 15%, 25%, 35%, or 65% of locked rotor torque and selectable kick start at 450% FLA for 0, 0.5, 1.0, or 1.5 s
  5. Power Circuit Ratings: Rated impulse voltage 6 kV, dielectric withstand 2500 V AC per IEC, insulation voltage 600 V AC per UL/CSA/NEMA, and DV/DT protection 1000 V/µs
  6. Auxiliary Contacts: TB-97 and TB-98 overload/fault contacts, 1 normally open electromagnetic relay contact rated 0.6 A at 120 V AC and 0.3 A at 240 V AC
  7. Mounting and Environment: Open type IP2X enclosure, 44.8 mm width, 110 mm depth, 139.7 mm height, operating temperature -5 to 50 °C, and 2000 m maximum altitude
150-C16NCD

Product Information

Technical Specifications

Specifications for 150-C16NCD

ParameterValue
Product FamilySMC-3
With displayFalse
Voltage type for actuatingAC/DC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz100
Rated control supply voltage at AC 60 Hz100
Overload current5.3
Controller typeSMC-3
DV/DT protection1000V/μs for power circuit
Repetitive peak voltage1600V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz per UL/CSA/NEMA for power circuit
Line connected motor power, max7.5 kW @ 500V AC @ 50Hz, 3-phase
Delta connected motor power, max7.5...20Hp @ 575V AC, 60 Hz, 3-phase
Overvoltage categoryIII per IEC for side mount auxiliary contacts
Rated impulse voltage6 kV for power circuit
Dielectric withstand2500V AC per IEC for power circuit
Line connected motor current5.3...16A @ 500/575V AC, 3-phase
Delta connected motor current9.1...27.6A @ 500/575V AC, 3-phase
Insulation voltageRated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Rated control power during start with fan215mA @ 120V AC/180mA @ 240V AC, 800mA @ 24V DC/660mA @ 24V AC
Input OFF-state current<10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit
Short-circuit protection device listNon-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contactsTB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max69kA @ 600V, maximum current 60 A time delay Class J or Class L fuse for inside delta connected motors
Type of currentTB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith)TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuitTB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contactsTB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization categoryTB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, maxTB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller featureSoft stop
Standard available fault current, max5 kA @ maximum standard fuse 70 A for delta device opsal current rating
Integrated motor overload protectionTrue
Short circuit protection device performance (SCPD) typeType 1
ParameterValue
Selectable overload trip classTrip Class 10, 15, or 20
Selectable start times2, 5, 10, 15, 20, 25, or 30 s
Input OFF-state voltage (IN1, IN2), max40V AC @ 17V DC/12V AC for control circuit
Selectable current limit150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2)85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Rated control power during start without fan205mA @ 120V AC/145mA @ 240V AC, 705mA @ 24V DC/580mA @ 24V AC
Input ON-state current (IN1, IN2)9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP)IP2X
Weight0.905
ShockOpsal: 15 G
Width44.8 mm (1.76 in)
Depth110 mm (4.33 in)
Height139.7 mm (5.5 in)
Cable size2.5...25 mm2 (14...4 AWG) for line power terminals
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
MakeTB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
BreakTB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Tightening torque2.3...3.4 Nm (30 in-lb) for line power terminals, 4.0 Nm (35 in-lb) if 25 mm2 (4 AWG) wire in top terminal for line power terminal
Internal bypassTrue
FunctionSingle direction
Selectable kick start - 450% FLA0, 0.5, 1.0, or 1.5 s
Selectable initial torque15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stopOff, 100%, 200%, or 300% of the start time setting when wired
Steady state heat dissipation14
Storage and transportation temperature-25
Rated surrounding temperature range without derating-5
Humidity5...95% noncondensing
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
EMC emission levelsRadiated emission: Class A per IEC
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2 per IEC
Altitude2000 m
Pollution degree2
Mounting hole size4.6
Number of polesEquipment is designed for 3-phase only for power circuit
EnclosureOpen type
RepairableNOT_REPAIRABLE
Preferred Availabilityfalse
Quick Turnaroundfalse
Dimension Height9.271
Lead Time5
Dimension Width18.415
Dimension Length18.796
Stock StatusSTOCKED
Weight UnitKG
Dimension UnitCM

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
Allen-Bradley 150-C16NCD Smart Motor Controller