Product Model
150-F780NCA
Material Number
—
Manufacturer
ROCKWELL
Product ID
106315

Get a Free Quote

Request pricing and availability for 150-F780NCA.

More parts to source? Send your whole list in one enquiry

Key specifications

Control Voltage
230...240V AC
Rated operating voltage Ue
200
DV/DT protection
RC snubber network for power circuit
Operating frequency
50/60 Hz for power circuit
Rated operational current
3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts
Weight
190.962
See all specifications

Product Highlights

  1. Motor Rating: 780 A controller rated 600 Hp at 460V AC, with line-connected motor power up to 800 kW at 690V/Y AC 50 Hz and delta-connected motor power up to 900 Hp at 575V AC 60 Hz
  2. Voltage Range: Rated operational voltage 200...600V AC (-15%, +10%) per UL/CSA/NEMA, with 230...240V AC control voltage
  3. Current Capability: Line-connected motor current 260...780 A at 600/Y/690V AC and delta-connected motor current 300...900 A at 500/575V AC
  4. Protection and Diagnostics: Integrated motor overload protection, trip classes 10, 15, 20 and 30, trip current rating 117% of motor FLC, and status indication for stopped, starting, stopping, at speed, alarm and fault
  5. Display and Control: LCD display and keypad, soft starter controller type, single-direction function, and internal bypass
150-F780NCA

Product Information

Technical Specifications

Specifications for 150-F780NCA

ParameterValue
Control Voltage230...240V AC
Controller Rating780 A 600Hp @ 460V AC
Product FamilySMC Flex
With displayYes
Voltage type for actuatingAC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz230 V
Rated control supply voltage at AC 60 Hz230 V
Overload current for line connected devices260 A
Overload current for delta connected devices300 A
Controller typeSoft starter
Control optionsNone
Trip classes10, 15, 20 and 30
Trip current rating117% of motor FLC
Heatsink fan rating150VA @ 110/120V AC or 220/240V AC
DV/DT protectionRC snubber network for power circuit
Repetitive peak inverse voltage rating1600V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz for power circuit
Line connected motor power, max800 kW @ 690V/Y AC, 50 Hz, 3-phase
Delta connected motor power, max900Hp @ 575V AC, 60 Hz, 3-phase
Rated impulse voltage6000V per IEC for power circuit
Dielectric withstand2500V per IEC for power circuit
Line connected motor current260...780 A @ 600/Y/690V AC, 3-phase
Delta connected motor current300...900A @ 500/575V AC, 3-phase
Ampere tested european style, max6, 6URD33xxx1400 @ 690V for maximum FLC
Ampere tested north american style, maxA070URD33xxx1400 @ 690V for maximum FLC
Transient protectionMetal oxide varistors: 220 J (optional) for power circuit
Insulation voltageRated 500V per IEC for power circuit
Rated operational voltage200...600V AC (-15%, +10%) per UL/CSA/NEMA for power circuit
Input OFF-state current<10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage
Short-circuit protection device listStandard fuse, circuit breaker and high capacity time delay class CC/J/L
Number of contacts1 for auxiliary contacts
High capacity available fault current, max74kA @ 600V, maximum current 1600 A time delay Class J or Class L fuse for line connected motors
Type of currentAC for auxiliary contacts
Conventional thermal current (Ith)AC/DC: 5 A for auxiliary contacts
Type of control circuitElectromagnetic relay for auxiliary contacts
Type of contactsProgmable NO/NC for auxiliary contacts
Utilization categoryMG 1 per UL/CSA/NEMA for power circuit
Standard controller featureStatus indication: stopped, starting, stopping, at speed, alarm and fault
Standard available fault current, max70kA @ 690V for maximum FLC
Optional controller featureSMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motor’s full-load current rating
Integrated motor overload protectionYes
ParameterValue
Short circuit protection device performance (SCPD) typeType 1
Number of sensors, max6 for PTC input ratings
Voltage at PTC terminals (RPTC = open), max30V for PTC input ratings
Voltage at PTC terminals (RPTC = 4 kΩ), max<7.5 for PTC input ratings
Transformer rating control module751 VA (recommended 800 VA)
Response time800 ms for PTC input ratings
Cold resistance of PTC sensor chain, max1500 ? for PTC input ratings
Tachometer input0...5V DC @ 4.5V DC = 100% Speed
Short circuit trip resistance25 ? ± 10 ? for PTC input ratings
Response resistance3400 ? ± 150 ? for PTC input ratings
Reset resistance1600 ? ± 100 ? for PTC input ratings
Input OFF-state voltage, max50V AC @ 10V DC/12V AC for control circuit
Input ON-state voltage, min85V AC @ 19.2V DC/20.4V AC for control circuit
Rated operational current3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts
Input ON-state current20mA @ 120V AC/40mA @ 240V AC, 7.6mA @ 24V AC/DC for control circuit
Contact typeAuxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4)
Steady state heat dissipation with control and fan power590 W
Storage and transportation temperature-20
Humidity5...95% (noncondensing)
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
Protection against electrical shockIP00 (open device) per IEC for power circuit
EMC emission levelsRadiated emission: Class A
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2
Altitude2000 m
Pollution degree2
Weight190.962
ShockOpsal: 4 G
Width596.9 mm (23.50 in)
Depth346.2 mm (13.63 in)
Height1041.1 mm (41 in)
Power pole constructionHeatsink hockey puck thyristor modular design
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Make3600VA for auxiliary contacts
Break360VA for auxiliary contacts
Internal bypassYes
FunctionSingle direction
Power terminal markingsNEMA, CENELEC EN50 012
Control terminalsClAing yoke connection, M3 screw clA
Line/load side power terminalsTwo 13.5 mm (0.53 in) diam holes per power pole
Number of poles3
EnclosureOpen type
Control modules constructionThermoset and thermoplastic moldings
Metal parts constructionPlated brass, copper or painted steel
RepairableREPAIRABLE
Preferred Availabilityfalse
Quick Turnaroundfalse
Dimension Height55.194
Lead Time20
Dimension Width77.394
Dimension Length128.194
Stock StatusNON_STOCKED
Weight UnitKG
Dimension UnitCM

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.