| Control Voltage | 230...240V AC |
|---|
| Controller Rating | 780 A 600Hp @ 460V AC |
|---|
| Product Family | SMC Flex |
|---|
| With display | Yes |
|---|
| Voltage type for actuating | AC |
|---|
| Rated operating voltage Ue | 200 |
|---|
| Rated control supply voltage at AC 50 Hz | 230 V |
|---|
| Rated control supply voltage at AC 60 Hz | 230 V |
|---|
| Overload current for line connected devices | 260 A |
|---|
| Overload current for delta connected devices | 300 A |
|---|
| Controller type | Soft starter |
|---|
| Control options | Brake control |
|---|
| Trip classes | 10, 15, 20 and 30 |
|---|
| Trip current rating | 117% of motor FLC |
|---|
| Heatsink fan rating | 150VA @ 110/120V AC or 220/240V AC |
|---|
| DV/DT protection | RC snubber network for power circuit |
|---|
| Repetitive peak inverse voltage rating | 1600V per UL/CSA/NEMA for power circuit |
|---|
| Operating frequency | 50/60 Hz for power circuit |
|---|
| Line connected motor power, max | 800 kW @ 690V/Y AC, 50 Hz, 3-phase |
|---|
| Delta connected motor power, max | 900Hp @ 575V AC, 60 Hz, 3-phase |
|---|
| Rated impulse voltage | 6000V per IEC for power circuit |
|---|
| Dielectric withstand | 2500V per IEC for power circuit |
|---|
| Line connected motor current | 260...780 A @ 600/Y/690V AC, 3-phase |
|---|
| Delta connected motor current | 300...900A @ 500/575V AC, 3-phase |
|---|
| Ampere tested european style, max | 6, 6URD33xxx1400 @ 690V for maximum FLC |
|---|
| Ampere tested north american style, max | A070URD33xxx1400 @ 690V for maximum FLC |
|---|
| Transient protection | Metal oxide varistors: 220 J (optional) for power circuit |
|---|
| Insulation voltage | Rated 500V per IEC for power circuit |
|---|
| Rated operational voltage | 200...600V AC (-15%, +10%) per UL/CSA/NEMA for power circuit |
|---|
| Input OFF-state current | <10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage |
|---|
| Short-circuit protection device list | Standard fuse, circuit breaker and high capacity time delay class CC/J/L |
|---|
| Number of contacts | 1 for auxiliary contacts |
|---|
| High capacity available fault current, max | 74kA @ 600V, maximum current 1600 A time delay Class J or Class L fuse for line connected motors |
|---|
| Type of current | AC for auxiliary contacts |
|---|
| Conventional thermal current (Ith) | AC/DC: 5 A for auxiliary contacts |
|---|
| Type of control circuit | Electromagnetic relay for auxiliary contacts |
|---|
| Type of contacts | Progmable NO/NC for auxiliary contacts |
|---|
| Utilization category | MG 1 per UL/CSA/NEMA for power circuit |
|---|
| Standard controller feature | Status indication: stopped, starting, stopping, at speed, alarm and fault |
|---|
| Standard available fault current, max | 70kA @ 690V for maximum FLC |
|---|
| Optional controller feature | SMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motorâs full-load current rating |
|---|
| Integrated motor overload protection | Yes |
|---|