- 150-F1250NZA
The Rockwell 150-F1250NZA is an SMC-Flex solid-state soft starter in an open-type enclosure with an integrated bypass and display. Its controller rating is 1250 A, 1000 Hp at 460V AC, with a rated operational voltage of 230...690V/Y (-15%, +10%) per IEC and 50/60 Hz operating frequency for the power circuit. Line-connected motor current is 416...1250 A at 600/Y/690V AC, three-phase; delta-connected motor current is 533...1600 A at 500/575V AC, three-phase. Control voltage is 230...240V AC. Trip classes are 10, 15, 20 and 30, with trip current at 117% of motor FLC. Dimensions are 596.9 mm width, 346.2 mm depth, and 1041.1 mm height.
- 150-F1250NZAB
The Rockwell 150-F1250NZAB is an SMC Flex soft starter with a 1250 A controller rating and 1000 Hp at 460V AC. It operates on 230...240V AC control voltage and a rated operational voltage of 230...690V/Y (-15%, +10%) per IEC for the power circuit, at 50/60 Hz. Line-connected motor current is 416...1250 A at 600/Y/690V AC, 3-phase; delta-connected motor current is 533...1600 A at 500/575V AC, 3-phase. Maximum line-connected motor power is 900 kW at 500V AC, 50 Hz, 3-phase. The unit includes an integrated bypass, integrated motor overload protection, a display, and programmable NO/NC auxiliary contacts. Trip classes are 10, 15, 20 and 30. Enclosure is open type, IP00 per IEC for the power circuit.
- 150-F1250NZAD
The Rockwell 150-F1250NZAD is an SMC Flex soft starter rated 1250 A and 1000 Hp at 460V AC. It operates at 50/60 Hz for the power circuit with a rated operating voltage of 230 V and control voltage of 230...240V AC. The unit includes a display and brake control. Overload current is 416 A for line-connected devices and 533 A for delta-connected devices. Trip classes are 10, 15, 20 and 30, with trip current at 117% of motor FLC. Maximum line-connected motor power is 900 kW at 500V AC, 50 Hz, three-phase; maximum delta-connected motor power is 900 kW at 400/415V AC, 50 Hz, three-phase. Rated impulse voltage is 6000V per IEC for the power circuit.
- 150-F135NBD
The Rockwell 150-F135NBD is an SMC Flex soft starter with a controller rating of 135 A and 25–100 Hp at 460V AC. It operates on 200...480V AC (-15%, +10%) per UL/CSA/NEMA for the power circuit at 50/60 Hz, with control voltage of 100...240V AC. Line-connected motor current is 34...135 A at 600/Y/690V AC, 3-phase; delta-connected motor current is 59...234 A at 500/575V AC, 3-phase. It includes integrated motor overload protection, internal bypass, a display, and trip classes 10, 15, 20, and 30. Steady-state heat dissipation with control and fan power is 104 W. The open-type enclosure measures 196.4 mm wide, 212.2 mm deep, and 443.7 mm high.
- 150-F135NBRB
The Rockwell 150-F135NBRB is a SMC Flex soft starter in the Smart Motor Controller category, rated 135 A and 25-100 Hp at 460V AC. It operates at 200V AC rated operating voltage and 50/60 Hz for the power circuit, with 24V AC/DC control voltage and a display. Overload current is 34 A for line-connected devices and 59 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. Maximum line-connected motor power is 90 kW at 500V AC, 50 Hz, three-phase. The power circuit includes an RC snubber network for DV/DT protection.
- 150-F135NCD
The Rockwell 150-F135NCD is a soft starter rated 135 A, 25–100 Hp at 460 V AC, with an integrated bypass and display. It operates at 200...600 V AC (-15%, +10%) per UL/CSA/NEMA, 50/60 Hz, 3-phase, with rated insulation voltage 500 V per IEC. Line-connected motor current is 34...135 A at 600/Y/690 V AC; delta-connected motor current is 59...234 A at 500/575 V AC. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. The controller includes programmable overload protection, DV/DT protection via an RC snubber network, and status indication for stopped, starting, stopping, at speed, alarm, and fault. Dimensions are 196.4 mm wide, 212.2 mm deep, and 443.7 mm high.
- 150-F135NCDB
The Rockwell Allen-Bradley 150-F135NCDB is an SMC Flex soft starter with a 135 A controller rating (25–100 Hp at 460V AC) and an integrated display. It operates on 200–600V AC three-phase input at 50/60 Hz, with a control voltage of 100–240V AC. Supported modes include soft start, current limit start, and soft stop, with pump control available. Protection features include an SCR bypass/run contactor, electronic motor overload protection, trip classes 10, 15, 20, and 30, and a trip current rating of 117% of motor FLC. Four programmable auxiliary contacts are provided. The transformer control module is rated 75VA at 100–240V AC (-15%, +10%). Operating temperature range is -5 to 50 degrees Celsius, up to 2000 meters altitude.
- 150-F135NCRB
Product identification: ROCKWELL 150-F135NCRB. The Allen-Bradley 150-F135NCRB is an SMC Flex smart motor controller configured as a soft starter with pump control and an integrated display. Its controller rating is 135 A, 25–100 Hp at 460V AC. Control voltage is 24V AC/DC, with rated control supply voltage of 24 V at both 50 Hz and 60 Hz. The power circuit operates at 50/60 Hz, with a repetitive peak inverse voltage rating of 1600V per UL/CSA/NEMA and RC snubber network DV/DT protection. Overload current is 34 A for line-connected devices and 59 A for delta-connected devices. Trip classes are 10, 15, 20 and 30, with trip current rating 117% of motor FLC. Maximum line-connected motor power is 90 kW at 500V AC, 50 Hz, 3-phase.