- 150-F135NBRB
The Rockwell 150-F135NBRB is a SMC Flex soft starter in the Smart Motor Controller category, rated 135 A and 25-100 Hp at 460V AC. It operates at 200V AC rated operating voltage and 50/60 Hz for the power circuit, with 24V AC/DC control voltage and a display. Overload current is 34 A for line-connected devices and 59 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. Maximum line-connected motor power is 90 kW at 500V AC, 50 Hz, three-phase. The power circuit includes an RC snubber network for DV/DT protection.
- 150-F135NCD
The Rockwell 150-F135NCD is a soft starter rated 135 A, 25–100 Hp at 460 V AC, with an integrated bypass and display. It operates at 200...600 V AC (-15%, +10%) per UL/CSA/NEMA, 50/60 Hz, 3-phase, with rated insulation voltage 500 V per IEC. Line-connected motor current is 34...135 A at 600/Y/690 V AC; delta-connected motor current is 59...234 A at 500/575 V AC. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. The controller includes programmable overload protection, DV/DT protection via an RC snubber network, and status indication for stopped, starting, stopping, at speed, alarm, and fault. Dimensions are 196.4 mm wide, 212.2 mm deep, and 443.7 mm high.
- 150-F135NCDB
The Rockwell Allen-Bradley 150-F135NCDB is an SMC Flex soft starter with a 135 A controller rating (25–100 Hp at 460V AC) and an integrated display. It operates on 200–600V AC three-phase input at 50/60 Hz, with a control voltage of 100–240V AC. Supported modes include soft start, current limit start, and soft stop, with pump control available. Protection features include an SCR bypass/run contactor, electronic motor overload protection, trip classes 10, 15, 20, and 30, and a trip current rating of 117% of motor FLC. Four programmable auxiliary contacts are provided. The transformer control module is rated 75VA at 100–240V AC (-15%, +10%). Operating temperature range is -5 to 50 degrees Celsius, up to 2000 meters altitude.
- 150-F135NCRB
Product identification: ROCKWELL 150-F135NCRB. The Allen-Bradley 150-F135NCRB is an SMC Flex smart motor controller configured as a soft starter with pump control and an integrated display. Its controller rating is 135 A, 25–100 Hp at 460V AC. Control voltage is 24V AC/DC, with rated control supply voltage of 24 V at both 50 Hz and 60 Hz. The power circuit operates at 50/60 Hz, with a repetitive peak inverse voltage rating of 1600V per UL/CSA/NEMA and RC snubber network DV/DT protection. Overload current is 34 A for line-connected devices and 59 A for delta-connected devices. Trip classes are 10, 15, 20 and 30, with trip current rating 117% of motor FLC. Maximum line-connected motor power is 90 kW at 500V AC, 50 Hz, 3-phase.
- 150-F135NZD
The Rockwell 150-F135NZD is an SMC Flex soft starter with an open-type enclosure and an integrated display. It is rated 135 A and 25–100 HP at 460 V AC, with a line-connected motor current range of 34–135 A at 600/Y/690 V AC, 3-phase. Rated operational voltage is 230–690 V/Y (-15%, +10%) per IEC for the power circuit, at 50/60 Hz. Control voltage is 100–240 V AC. Trip classes are 10, 15, 20 and 30, with trip current at 117% of motor FLC. Integrated motor overload protection is included, and internal bypass is provided. Dimensions are 196.4 mm wide, 212.2 mm deep and 443.7 mm high.
- 150-F135NZDB
The Rockwell 150-F135NZDB is an SMC Flex soft starter with an open-type enclosure, integral bypass, and display. It is rated 135 A and 25–100 Hp at 460 V AC, with line-connected motor current of 34–135 A at 600/Y/690 V AC, 3-phase, and delta-connected motor current of 59–234 A at 500/575 V AC, 3-phase. Control voltage is 100–240 V AC; the power circuit operates at 50/60 Hz with a rated operational voltage of 230–690 V/Y (-15%, +10%) per IEC. Trip classes are 10, 15, 20, and 30, and trip current is 117% of motor FLC. Integrated motor overload protection is included. Dimensions are 196.4 mm wide, 212.2 mm deep, and 443.7 mm high.
- 150-F201NBD
The Rockwell 150-F201NBD is an SMC Flex soft starter with an integrated display. Its controller rating is 201 A, 75–150 Hp at 460V AC, and it operates from a 200V AC rated operating voltage with 100...240V AC control voltage. The power circuit runs at 50/60 Hz, and line-connected motor power is 75 Hp at 230V AC, 60 Hz, three-phase. Overload current is 67 A for line-connected devices and 116 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with a trip current rating of 117% of motor FLC. The transformer control module is rated 75VA at 100...240V AC (-15%, +10%).
- 150-F201NBDD
The Rockwell 150-F201NBDD is an SMC Flex soft starter with an open-type enclosure and integrated display. Its controller rating is 201 A, 75–150 Hp at 460V AC, with a rated operating voltage of 200 V and control voltage of 100...240V AC. Power circuit operating frequency is 50/60 Hz, and the rated operational voltage is 200...480V AC (-15%, +10%) per UL/CSA/NEMA. Line-connected motor current is 67...201 A at 600/Y/690V AC, three-phase; delta-connected motor current is 116...348 A at 500/575V AC, three-phase. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. Integrated motor overload protection is included. Operating temperature for the open enclosure is -5 to 50 °C (23 to 122 °F).