Q1Can you supply the ROCKWELL 150-C108NCD?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ROCKWELL 150-C108NCD cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
150-C108NCD
Material Number
—
Manufacturer
ROCKWELL
Product ID
105506

Get a Free Quote

Request pricing and availability for 150-C108NCD.

More parts to source? Send your whole list in one enquiry

Key specifications

Voltage type for actuating
AC/DC
Rated operating voltage Ue
200
Fan power rating
20 VA
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit
Rated operational current, max
TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Weight
16.825
See all specifications

Product Highlights

  1. Starting and Stopping Modes: Selectable soft start, soft stop, current limit at 150%, 250%, 350%, or 450% of full load current, and kick start at 450% FLA for 0, 0.5, 1.0, or 1.5 s
  2. Configurable Timing and Torque: Selectable start times of 2, 5, 10, 15, 20, 25, or 30 s, initial torque of 15%, 25%, 35%, or 65% of locked rotor torque, and soft stop of off, 100%, 200%, or 300% of the start time setting
  3. Motor and Circuit Protection: Integrated motor overload protection with selectable trip class 10, 15, or 20, internal bypass, and Type 1 short-circuit protection device performance
  4. Delta Connected Motor Capability: Supports delta connected motor current of 47 to 187 A at 500/575 V AC, 3-phase, with maximum available fault current of 70 kA at 600 V
  5. Power Circuit Ratings: Rated operating voltage 200 V, insulation voltage 600 V AC per UL/CSA/NEMA, impulse voltage 6 kV, dielectric withstand 2500 V AC per IEC, and DV/DT protection of 1000 V/µs
  6. Auxiliary Overload/Fault Contacts: One normally open electromagnetic relay contact (TB-97, TB-98) rated 1 A thermal current, 0.6 A at 120 V AC and 0.3 A at 240 V AC, AC/DC
  7. Control Inputs: ON-state current 9.8 mA at 120 V AC, 19.6 mA at 240 V AC, and 7.3 mA at 24 V AC/DC, with OFF-state current below 10 mA and OFF-state voltage up to 40 V AC
  8. Physical and Environmental Data: Open type enclosure, IP2X degree of protection, dimensions 196.4 mm width by 205.2 mm depth by 443.7 mm height, weight 16.825 kg, operating temperature -5 to 50 °C, and 3-phase power circuit only
150-C108NCD

Product Information

Technical Specifications

Specifications for 150-C108NCD

ParameterValue
Product FamilySMC-3
With displayNo
Voltage type for actuatingAC/DC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz100
Rated control supply voltage at AC 60 Hz100
Fan power rating20 VA
Overload current27 A
Controller typeSMC-3
DV/DT protection1000V/μs for power circuit
Repetitive peak voltage1600V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz per UL/CSA/NEMA for power circuit
Overvoltage categoryIII per IEC for side mount auxiliary contacts
Rated impulse voltage6 kV for power circuit
Dielectric withstand2500V AC per IEC for power circuit
Delta connected motor current47...187A @ 500/575V AC, 3-phase
Insulation voltageRated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Rated control power during start with fan200mA @ 120V AC/120mA @ 240V AC, 600mA @ 24V AC/DC
Input OFF-state current<10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit
Short-circuit protection device listNon-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contactsTB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max70kA @ 600V, maximum current 400 A time delay Class J or Class L fuse for inside delta connected motors
Type of currentTB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith)TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuitTB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contactsTB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization categoryTB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, maxTB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller featureSoft stop
Standard available fault current, max10 kA @ maximum standard fuse 600 A for delta device opsal current rating
Integrated motor overload protectionYes
Short circuit protection device performance (SCPD) typeType 1
Selectable overload trip classTrip Class 10, 15, or 20
ParameterValue
Selectable start times2, 5, 10, 15, 20, 25, or 30 s
Input OFF-state voltage (IN1, IN2), max40V AC @ 17V DC/12V AC for control circuit
Selectable current limit150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2)85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Input ON-state current (IN1, IN2)9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP)IP2X
Weight16.825
ShockOpsal: 15 G
Width196.4 mm (7.74 in)
Depth205.2 mm (8.08 in)
Height443.7 mm (17.47 in)
Cable size0.2...2.5 mm2 (24...14 AWG) for control terminals
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
MakeTB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
BreakTB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Tightening torque0.45...0.9 Nm (4.0...8.0 in-lb) for control terminals
Internal bypassYes
FunctionSingle direction
Selectable kick start - 450% FLA0, 0.5, 1.0, or 1.5 s
Selectable initial torque15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stopOff, 100%, 200%, or 300% of the start time setting when wired
Steady state heat dissipation62 W
Storage and transportation temperature-25 °C
Rated surrounding temperature range without derating-5 °C
Humidity5...95% noncondensing
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
EMC emission levelsRadiated emission: Class A per IEC
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2 per IEC
Altitude2000 m
Pollution degree2
Mounting hole size7.5 mm
Number of polesEquipment is designed for 3-phase only for power circuit
Power pole holesOne M10 x 1.5 diam hole per power pole for load Power Terminals
EnclosureOpen type
RepairableREPAIRABLE
Preferred Availabilityfalse
Quick Turnaroundfalse
Dimension Height34.925
Lead Time21
Dimension Width36.195
Dimension Length62.23
Stock StatusSTOCKED