Product Model
150-C135NCR
Material Number
—
Manufacturer
ROCKWELL
Product ID
107602

Get a Free Quote

Request pricing and availability for 150-C135NCR.

More parts to source? Send your whole list in one enquiry

Key specifications

Voltage type for actuating
AC/DC
Rated operating voltage Ue
200
Fan power rating
20 VA
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit
Rated operational current, max
TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Weight
15.78
See all specifications

Product Highlights

  1. Three-Phase Soft Starter: SMC-3 controller for single-direction, 3-phase motors with soft stop and integrated motor overload protection
  2. Current and Power Ratings: Delta-connected motor current 59 to 234 A at 500/575 V AC, maximum line-connected motor power 90 kW at 500 V AC, 50 Hz
  3. Selectable Starting Parameters: Start times of 2, 5, 10, 15, 20, 25, or 30 s, initial torque of 15, 25, 35, or 65 percent of locked rotor torque, current limit of 150, 250, 350, or 450 percent FLA, and kick start of 0, 0.5, 1.0, or 1.5 s at 450 percent FLA
  4. Overload Trip Class: Selectable Trip Class 10, 15, or 20 with Type 1 short-circuit protection device performance
  5. Internal Bypass: Yes, with 24 V AC/DC control supply voltage and 200 mA at 120 V AC or 120 mA at 240 V AC control power during start with fan
  6. Auxiliary Fault Contacts: One normally open TB-97/-98 overload/fault contact rated 0.6 A at 120 V AC and 0.3 A at 240 V AC
  7. Power Circuit Protection: 1000 V/microsecond DV/DT protection, 1600 V repetitive peak voltage, 6 kV rated impulse voltage, and 2500 V AC dielectric withstand
  8. Open-Type Enclosure: IP2X degree of protection, 196.4 mm width, 205.2 mm depth, 443.7 mm height, and 15.78 kg weight
  9. Operating Conditions: -5 to 50 degrees C open operating temperature, 5 to 95 percent noncondensing humidity, 2000 m altitude, and pollution degree 2
150-C135NCR

Product Information

Technical Specifications

Specifications for 150-C135NCR

ParameterValue
Product FamilySMC-3
With displayNo
Voltage type for actuatingAC/DC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz24 V
Rated control supply voltage at AC 60 Hz24 V
Fan power rating20 VA
Controller typeSMC-3
DV/DT protection1000V/μs for power circuit
Repetitive peak voltage1600V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz per UL/CSA/NEMA for power circuit
Line connected motor power, max90 kW @ 500V AC @ 50Hz, 3-phase
Overvoltage categoryIII per IEC for side mount auxiliary contacts
Rated impulse voltage6 kV for power circuit
Dielectric withstand2500V AC per IEC for power circuit
Delta connected motor current59...234A @ 500/575V AC, 3-phase
Insulation voltageRated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Rated control power during start with fan200mA @ 120V AC/120mA @ 240V AC, 600mA @ 24V AC/DC
Input OFF-state current<10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit
Short-circuit protection device listNon-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contactsTB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max70kA @ 600V, maximum current 400 A time delay Class J or Class L fuse for inside delta connected motors
Type of currentTB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith)TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuitTB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contactsTB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization categoryTB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, maxTB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller featureSoft stop
Rated control supply voltage at DC24 V
Integrated motor overload protectionYes
Short circuit protection device performance (SCPD) typeType 1
ParameterValue
Selectable overload trip classTrip Class 10, 15, or 20
Selectable start times2, 5, 10, 15, 20, 25, or 30 s
Input OFF-state voltage (IN1, IN2), max40V AC @ 17V DC/12V AC for control circuit
Selectable current limit150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2)85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Input ON-state current (IN1, IN2)9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP)IP2X
Weight15.78
ShockOpsal: 15 G
Width196.4 mm (7.74 in)
Depth205.2 mm (8.08 in)
Height443.7 mm (17.47 in)
Cable size0.2...2.5 mm2 (24...14 AWG) for control terminals
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
MakeTB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
BreakTB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Tightening torque0.45...0.9 Nm (4.0...8.0 in-lb) for control terminals
Internal bypassYes
FunctionSingle direction
Selectable kick start - 450% FLA0, 0.5, 1.0, or 1.5 s
Selectable initial torque15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stopOff, 100%, 200%, or 300% of the start time setting when wired
Mounting hole size7.5 mm
Number of polesEquipment is designed for 3-phase only for power circuit
Power pole holesOne M10 x 1.5 diam hole per power pole for load Power Terminals
EnclosureOpen type
Storage and transportation temperature-25 °C
Rated surrounding temperature range without derating-5 °C
Humidity5...95% noncondensing
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
EMC emission levelsRadiated emission: Class A per IEC
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2 per IEC
Altitude2000 m
Pollution degree2
RepairableREPAIRABLE
Preferred Availabilityfalse
Quick Turnaroundfalse
Dimension Height34.29
Lead Time10
Dimension Width30.81
Dimension Length64.11
Stock StatusNON_STOCKED
Weight UnitKG
Dimension UnitCM

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
Allen Bradley 150-C135NCR Smart Motor Controller - Efficient 3-Phase Control