- 140G-M-TLC23
Product identification: ROCKWELL 140G-M-TLC23. Terminal lug for M Frame circuit breakers. Accepts two conductors sized 250–500 MCM or 120–240 mm², copper wire only. The lug is not repairable. Dimensions: height 5.21, width 14.61, length 19.0; weight 0.95 kg.
- 140G-M-TLC24
The 140G-M-TLC24 is a motor protection circuit breaker from Rockwell. It accepts two 250–500 MCM or 120–240 mm² copper conductors. It is UL Listed, CSA Certified, and CE marked, and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 4.318 high, 13.081 wide, and 18.034 long. The device is not repairable.
- 140G-M-TLC33
Product identification: ROCKWELL 140G-M-TLC33. Terminal lugs for the Allen-Bradley 140G-M-TLC33 motor protection circuit breaker. Accepts three conductors sized 2/0 to 400 MCM or 70 to 185 mm2, copper wire only. Dimensions: 17.09 mm height, 15.6 mm width, 30.3 mm length. The accessory is not repairable.
- 140G-M-TLC34
Product identification: ROCKWELL 140G-M-TLC34. The Allen-Bradley 140G-M-TLC34 is a motor protection circuit breaker. It accepts three copper conductors sized 2/0 to 400 MCM or 70 to 185 mm2. It is UL Listed, CSA Certified, and CE marked, and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 15.001 mm high, 16.901 mm wide, and 30.201 mm long. The device is not repairable.
- 140G-M-TS
Product identification: ROCKWELL 140G-M-TS. The 140G-M-TS is a motor protection circuit breaker. It provides interrupting ratings up to 65 kA. A range of trip units is available for configuration. The breaker is constructed to withstand demanding operating conditions.
- 140G-M0F3-D60-CJ
Rockwell molded case circuit breaker, display model 140G-M0F3-D60-CJ. Three-pole device with a rated permanent current Iu of 600 A and an 800 A frame size. Thermal trip current Ir is 420 A; magnetic trip current Im is 3000 A. Thermal trip rating maximum is 600 A at an ambient temperature of 40 °C. Insulation voltage Ui is rated 1000 V per IEC, and rated impulse withstand voltage Uimp is 8 kV. Rated ultimate short-circuit breaking capacity Icu is 80 kA at 440 V AC, 50/60 Hz, per IEC 60947-2. The toggle-operated breaker has a screw-type front main circuit connection, IP40 degree of protection, and dimensions of 268 mm height, 210 mm width, and 103.5 mm depth.
- 140G-M0F3-D80-Z1
The ROCKWELL 140G-M0F3-D80-Z1 is a 3-pole motor protection circuit breaker with a rated permanent current Iu of 800 A and an 800 A frame size. It uses a toggle control element and a thermal-magnetic protection unit with adjustable thermal trip current Ir of 560 A and adjustable magnetic trip current Im of 4000 A. Rated impulse withstand voltage Uimp is 8 kV, and insulation voltage Ui is rated 1000 V per IEC. Rated ultimate short-circuit breaking capacity Icu is 80 kA at 440 V AC, 50/60 Hz per IEC 60947-2. Thermal trip rating is 800 A at 40 °C ambient. Watt loss is 93 W for the thermal-magnetic type. No integrated undervoltage release or earth fault protection is included.
- 140G-M0F4-D60-AA
The Rockwell 140G-M0F4-D60-AA is a 4-pole motor protection circuit breaker with a complete device and protection unit. It has a rated permanent current Iu of 600 A, a thermal trip current Ir of 420 A, and a magnetic trip current Im of 3000 A. The frame size is 800 A. It uses a toggle control element and includes one auxiliary change-over contact, with no integrated under voltage release or earth fault protection. Rated impulse withstand voltage Uimp is 8 kV, and insulation voltage Ui is rated 1000 V per IEC. Thermal trip rating is 600 A at 40 °C ambient. Interrupting rating is 50 kA at 600 V DC, 3-pole in series, thermal-magnetic trip only per NEMA, UL, and CSA. IEC 60947-2 Icu is 80 kA at 440 V AC, 50/60 Hz.