- 140G-M-TLC33
Product identification: ROCKWELL 140G-M-TLC33. Terminal lugs for the Allen-Bradley 140G-M-TLC33 motor protection circuit breaker. Accepts three conductors sized 2/0 to 400 MCM or 70 to 185 mm2, copper wire only. Dimensions: 17.09 mm height, 15.6 mm width, 30.3 mm length. The accessory is not repairable.
- 140G-M-TLC34
Product identification: ROCKWELL 140G-M-TLC34. The Allen-Bradley 140G-M-TLC34 is a motor protection circuit breaker. It accepts three copper conductors sized 2/0 to 400 MCM or 70 to 185 mm2. It is UL Listed, CSA Certified, and CE marked, and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 15.001 mm high, 16.901 mm wide, and 30.201 mm long. The device is not repairable.
- 140G-M-TS
Product identification: ROCKWELL 140G-M-TS. The 140G-M-TS is a motor protection circuit breaker. It provides interrupting ratings up to 65 kA. A range of trip units is available for configuration. The breaker is constructed to withstand demanding operating conditions.
- 140G-M0F3-D60-CJ
Rockwell molded case circuit breaker, display model 140G-M0F3-D60-CJ. Three-pole device with a rated permanent current Iu of 600 A and an 800 A frame size. Thermal trip current Ir is 420 A; magnetic trip current Im is 3000 A. Thermal trip rating maximum is 600 A at an ambient temperature of 40 °C. Insulation voltage Ui is rated 1000 V per IEC, and rated impulse withstand voltage Uimp is 8 kV. Rated ultimate short-circuit breaking capacity Icu is 80 kA at 440 V AC, 50/60 Hz, per IEC 60947-2. The toggle-operated breaker has a screw-type front main circuit connection, IP40 degree of protection, and dimensions of 268 mm height, 210 mm width, and 103.5 mm depth.
- 140G-M0F3-D80-Z1
The ROCKWELL 140G-M0F3-D80-Z1 is a 3-pole motor protection circuit breaker with a rated permanent current Iu of 800 A and an 800 A frame size. It uses a toggle control element and a thermal-magnetic protection unit with adjustable thermal trip current Ir of 560 A and adjustable magnetic trip current Im of 4000 A. Rated impulse withstand voltage Uimp is 8 kV, and insulation voltage Ui is rated 1000 V per IEC. Rated ultimate short-circuit breaking capacity Icu is 80 kA at 440 V AC, 50/60 Hz per IEC 60947-2. Thermal trip rating is 800 A at 40 °C ambient. Watt loss is 93 W for the thermal-magnetic type. No integrated undervoltage release or earth fault protection is included.
- 140G-M0F4-D60-AA
The Rockwell 140G-M0F4-D60-AA is a 4-pole motor protection circuit breaker with a complete device and protection unit. It has a rated permanent current Iu of 600 A, a thermal trip current Ir of 420 A, and a magnetic trip current Im of 3000 A. The frame size is 800 A. It uses a toggle control element and includes one auxiliary change-over contact, with no integrated under voltage release or earth fault protection. Rated impulse withstand voltage Uimp is 8 kV, and insulation voltage Ui is rated 1000 V per IEC. Thermal trip rating is 600 A at 40 °C ambient. Interrupting rating is 50 kA at 600 V DC, 3-pole in series, thermal-magnetic trip only per NEMA, UL, and CSA. IEC 60947-2 Icu is 80 kA at 440 V AC, 50/60 Hz.
- 140G-M0F4-D63
Rockwell motor protection circuit breaker, model 140G-M0F4-D63, M-Frame, rated 800 A with a 630 A trip unit. Protection is thermal-magnetic, with adjustable thermal and adjustable magnetic settings. UL interrupting rating is 100 kA at 480 V. The device is not repairable. It carries UL Listed, CSA Certified, CE, and CCC certifications, and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 28.5 cm height, 30.5 cm width, and 37.0 cm length; weight is 11.975 kg. Stock status is non-stocked, with a lead time of 36.
- 140G-M0H3-D63
The Rockwell 140G-M0H3-D63 is a motor protection circuit breaker with electronic protection and a rated current of 630 A. It is a three-pole device with an IEC breaking capacity of 120 kA at 415 V. It complies with UL489, CSA22.2 No. 5, and IEC 60947-2, and holds UL Listed, CSA Certified, CE, and CCC certifications. Dimensions are 38.1 cm length, 30.48 cm width, and 27.94 cm height, with a weight of 10.233 kg. The device is not repairable. It is non-stocked, with a lead time of 5 days. Preferred availability and quick turnaround are both false.