- vaba-s6-1-x1
Festo VABA-S6-1-X1 pneumatic valve manifold interface, manufacturer ID 543416. It connects to Type 44 and VTSA valve manifolds and is actuated via fieldbus through a CPX connection. It supports up to 16 valve positions for bistable pneumatic valves or 32 for monostable pneumatic valves. Diagnostics cover undervoltage of pneumatic valves, with one group diagnostics LED and channel status LEDs on the pneumatic valves. Parameterization includes fail-safe modes, forcing, idle mode per channel, and module monitoring. Each pneumatic valve output has an internal electronic fuse. DC operating voltage range is 21.6V to 26.4V, nominal 24V. Maximum power supply per channel is 0.2 A; maximum residual current per module is 4A. Degree of protection is IP65 NEMA 4; ambient temperature range is -5°C to 50°C. Weight is 590g.
- vaba-s6-1-x1-3v-cb
Festo VABA-S6-1-X1-3V-CB is an accessory interface for pneumatic valves, for valve manifold type 44, VTSA. It supports up to 12 valve positions with bistable pneumatic valves or 24 with monostable pneumatic valves. Diagnostics include wire break per valve coil, short circuit of pneumatic valves, and undervoltage of pneumatic valves. Parameterization covers fail-safe modes, forcing, idle mode per channel, and module monitoring. Internal electronic fuse protection is provided per pneumatic valve output. DC operating voltage range is 21.6V to 26.4V at a nominal 24V DC. Electrical connection is 3x M12x1 A-coded 5-pin plug via CPX. Degree of protection is IP65 NEMA 4, ambient temperature -5°C to 50°C, weight 580g.
- vaba-s6-1-x1-cb
Festo VABA-S6-1-X1-CB (Manufacturer ID 8082877) is an accessory for pneumatic valves, providing a valve manifold interface for Type 44 and VTSA. It supports up to 12 valve positions with bistable pneumatic valves or 24 with monostable valves. Diagnostics cover wire break per valve coil, short circuit of pneumatic valves, and undervoltage of pneumatic valves. Parameterization includes fail-safe modes, forcing, and idle mode per channel, plus module monitoring. Electrical connection is via CPX with fieldbus actuation. DC operating voltage range is 21.6V to 26.4V at a nominal 24V DC. Maximum power supply per channel is 0.2 A; maximum residual current per module is 6A. Protection is IP65 NEMA 4, ambient temperature -5°C to 50°C, weight 560g.
- vaba-s6-1-x2
Festo VABA-S6-1-X2 pneumatic valve manifold interface for Type 44, VTSA valve manifolds, with manufacturer ID 550663. It supports up to 16 valve positions with bistable pneumatic valves or 32 with monostable pneumatic valves. Diagnostics cover undervoltage of pneumatic valves. Parameterization includes fail-safe modes, forcing, and idle mode per channel, plus module monitoring. Each pneumatic valve output has an internal electronic fuse. DC operating voltage range is 21.6V to 26.4V at a nominal 24V. Maximum power supply per channel is 0.2 A; maximum residual current per module is 4 A. Degree of protection is IP65 NEMA 4, ambient temperature -5°C to 50°C, weight 590g. Electrical actuation is fieldbus, connection via CPX.
- vaba-s6-1-x2-3v-cb
Festo VABA-S6-1-X2-3V-CB pneumatic valve accessory, manufacturer ID 8082878, for valve manifold interface Type 44, VTSA. It supports up to 12 valve positions for bistable pneumatic valves or 24 for monostable pneumatic valves. Diagnostics cover wire break per valve coil, short circuit of pneumatic valves, and undervoltage of pneumatic valves. LED indicators show group diagnostics, three load supplies, and channel status on pneumatic valves. Parameterization includes fail-safe modes, forcing, and idle mode per channel, plus module monitoring. Internal electronic fuse protection is provided per pneumatic valve output. DC operating voltage range is 21.6V to 26.4V at nominal 24V. Electrical connection: 3x M12x1 A-coded 5-pin plug, via CPX. Degree of protection IP65 NEMA 4; ambient temperature -5°C to 50°C; weight 580g.
- vaba-s6-1-x2-cb
Festo VABA-S6-1-X2-CB is an interface for pneumatic valve manifolds, manufacturer ID 8082876. It connects via CPX and interfaces with Type 44 and VTSA valve manifolds, with electrical actuation through a fieldbus. It supports up to 24 monostable or 12 bistable valve positions. Diagnostics cover wire break per valve coil, short circuit of pneumatic valves, and undervoltage of pneumatic valves. Parameterization includes fail-safe modes, forcing, idle mode per channel, and module monitoring. Internal electronic fuse protection is provided per pneumatic valve output. DC operating voltage range is 21.6V to 26.4V at a nominal 24V. Maximum power supply per channel is 0.2 A, and maximum residual current per module is 6A. Degree of protection is IP65 NEMA 4, ambient temperature -5°C to 50°C, weight 560g.
- vaba-s6-1-x2-d
Festo valve manifold interface for Type 44, VTSA valve manifolds, identified by model VABA-S6-1-X2-D and manufacturer ID 573613. It supports up to 16 bistable or 32 monostable pneumatic valve positions. Electrical actuation is via fieldbus, with connection through CPX. Internal electronic fuse protection is provided per pneumatic valve output. Diagnostics cover undervoltage of pneumatic valves; LED indicators show group diagnostics and channel status on pneumatic valves. Parameterization includes fail-safe modes, forcing, and idle mode per channel, plus module monitoring. DC operating voltage range is 21.6 V to 26.4 V, nominal 24 V. Maximum power supply per channel is 0.2 A; maximum residual current per module is 4 A. Degree of protection is IP65 NEMA 4. Ambient temperature range is -5°C to 50°C. Product weight is 590 g.
- vaba-s6-1-x2-f1-cb
Festo pneumatic valve accessory, display model vaba-s6-1-x2-f1-cb, manufacturer ID 8068240. Valve manifold interface type 44, VTSA-F-CB, with electrical actuation via fieldbus and connection via CPX. Supports up to 12 valve positions for bistable pneumatic valves or 24 for monostable pneumatic valves. Diagnostics cover wire break per valve coil, short circuit of pneumatic valves, and undervoltage of pneumatic valves; internal electronic fuse per pneumatic valve output. Parameterization includes fail-safe modes, forcing, and idle mode per channel, plus module monitoring. DC operating voltage range 21.6V to 26.4V, nominal 24V; maximum power supply per channel 0.2 A; maximum residual current per module 4.5A. Ambient temperature -5°C to 50°C, storage temperature -20°C to 60°C, IP65, weight 734g.