- VB6S-30-01-P1.7-71
ABB invertible contactor VB6S-30-01-P1.7-71, manufacturer ID GJL1213909R7011. Three-pole device with three NO main contacts and one NC auxiliary contact. Rated control circuit voltage is 24 V DC. Rated operational voltage is 690 V AC for main and auxiliary circuits, 220 V DC for the main circuit, and 250 V DC for the auxiliary circuit. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Dimensions are 96.2 mm width, 57.5 mm height, and 47.7 mm depth; net weight 0.355 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- VB6S-30-10-1.7-71
ABB invertible contactor VB6S-30-10-1.7-71, manufacturer ID GJL1213901R7101. Three-pole device with three NO main contacts and one NO auxiliary contact. Rated control circuit voltage is 24 V DC. Rated operational voltage is 690 V AC for main and auxiliary circuits, 220 V DC for the main circuit and 250 V DC for the auxiliary circuit. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V for 40 °C and 55 °C. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase, 2.2 kW at 230 V, and 3 kW at 690 V. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.355 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VB6SA-30-10-1.7-71
ABB invertible contactor VB6SA-30-10-1.7-71, manufacturer ID GJL1213911R7101. Three-pole device with 3 NO main contacts and 1 NO auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 24 V DC; coil operating limits 0.85 to 1.1 x Uc at ambient temperature up to 55 °C per IEC 60947-4-1. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V. Rated operational power AC-3: 2.2 kW at 230 V, 4 kW at 400 V and 500 V, 3 kW at 690 V. Dimensions 96.2 x 57.5 x 46.7 mm; net weight 0.355 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VB6SA-30-10-P-2.8
The ABB VB6SA-30-10-P-2.8 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 47.7 mm deep, and weighs 0.345 kg. The control circuit is rated 17 to 32 V DC; coil operating limits are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C, per IEC 60947-4-1. Main circuit rated operational voltage is 690 V AC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- VB7-30-01-01
The ABB VB7-30-01-01 is an invertible contactor with three normally open main contacts and one normally closed auxiliary contact. Its 24 V AC control coil operates within 0.85 to 1.1 times Uc for AC supply at ambient temperatures up to 55 °C, per IEC 60947-4-1. Rated operational power in AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both temperatures. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth, weighing 0.355 kg. Main circuit terminals are IP20. Mechanical durability is 10,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB7-30-01-02
The ABB VB7-30-01-02 is an invertible contactor with three poles, three main contacts NO, and one auxiliary contact NC. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and insulation voltage of 690 V. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, 5.5 kW at 500 V three-phase, and 3 kW at 690 V three-phase. The control circuit voltage is 42 V AC, and mechanical durability is 10,000,000 cycles. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- VB7-30-01-03
The ABB VB7-30-01-03 is a compact 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational power in AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, and 5.5 kW at 500 V three-phase. The coil is rated 48 V AC, 50/60 Hz. Mechanical durability is 10,000,000 cycles. Ambient operating temperature is -20 to +55 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, and IEC/EN 60947-5-1.
- VB7-30-01-80
The ABB VB7-30-01-80 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. The control circuit voltage is 220 to 240 V AC. Mechanical durability is 10,000,000 cycles. Main circuit terminals are IP20. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.