Industrial Automation Parts. Prompt replies from real people.

Festo VABA-S6-1-X5 Pneumatic Interface

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the Festo vaba-s6-1-x5?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the Festo vaba-s6-1-x5 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
vaba-s6-1-x5
Material Number
8154036
Manufacturer
Festo
Product ID
918

Get a Free Quote

Request pricing and availability for vaba-s6-1-x5.

More parts to source? Send your whole list in one enquiry

Key specifications

Valve manifold interface
Type 44, VTSA Type 45, VTSA-F
Reverse polarity protection
yes
Intrinsic current consumption at nominal operating voltage for electronics/sensors
typically 27 mA
Intrinsic current consumption at nominal operating voltage load
typically 17 mA
Ambient temperature
-20°C – 50°C
Product weight
1245g
See all specifications

Product Highlights

  1. Valve manifold interface: Type 44, VTSA Type 45, and VTSA-F
  2. Valve capacity: up to 16 bistable or 32 monostable pneumatic valve positions and up to 32 solenoid coils
  3. Electrical and communication: fieldbus actuation with AP protocol, internal cycle time below 1 ms, and reverse polarity protection
  4. Diagnostics: per-module LED diagnostics for load power supply, internal communication, load switch-off, communication errors, output short-circuit/overload, and electronics/sensors and load overvoltage or undervoltage
  5. Power supply: 24 V DC nominal for electronics/sensors and load, with potential separation between the two supply voltages, internal electronic fuse per pneumatic valve output, and 10 ms power failure buffering
  6. Operating conditions: ambient temperature -20°C to 50°C, storage temperature -20°C to 70°C, relative air humidity 5 to 95 % non-condensing, and vibration and shock resistance severity level 2 per FN 942017-4/EN 60068-2-6 and FN 942017-5/EN 60068-2-27 when wall-mounted
  7. Dimensions and mounting: 70.5 mm x 142 mm x 102.6 mm, 1245 g, mounted with through-hole for M6 screw
  8. Materials and compliance: aluminum housing, powder-coated zinc die-cast cover, NBR and PUR seals, nickel-plated steel screws, RoHS-compliant, halogen-free, and free of phosphoric acid ester
vaba-s6-1-x5

Product Information

Technical Specifications

Specifications for vaba-s6-1-x5

ParameterValue
Vibration resistanceTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6
Note on vibration resistanceSG2 on wall mounting
Shock resistanceShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27
Note on shock resistanceSG2 on wall mounting
Valve manifold interfaceType 44, VTSA Type 45, VTSA-F
Reverse polarity protectionyes
Diagnostics via LEDDiagnostics per module Load power supply
Diagnose per internal communicationLoad switch-off Communication error Short-circuit/overload in output signal Electronics/sensors overvoltage Load overvoltage Electronics/sensors undervoltage Load undervoltage
Max. no. of valve positions16 for bistable pneumatic valves 32 for monostable pneumatic valves
Max. no. of solenoid coils32
Module code (hex/dec)0x3044/12356d
Module parametersActivation of diagnosis in case of overload/short circuit Condition counter limit/actual value Configuration of voltage monitoring, load supply PL Response in error state
Internal cycle time< 1 ms
Dimensions W x L x H70.5 mm x 142 mm x 102.6 mm
Fuse protection (short circuit)Internal electronic fuse per pneumatic valve output
Intrinsic current consumption at nominal operating voltage for electronics/sensorstypically 27 mA
Intrinsic current consumption at nominal operating voltage loadtypically 17 mA
Note regarding operating voltageSELV/PELV fixed power supplies required Note voltage drop
Nominal operating voltage DC for electronics/sensors24V
Nominal operating voltage DC load24V
ParameterValue
Power failure buffering10ms
Potential separation between the supply voltages electronics/sensor technology and load/valvesyes
Contamination level2
Permissible voltage fluctuations for electronics/sensors± 25 %
Permissible voltage fluctuations load± 10%
Undervoltage load/valves (diagnostic message)21.6V
Corrosion resistance class (CRC)0 - No corrosion stress
LABS (PWIS) conformityVDMA24364-B2-L
Storage temperature-20°C – 70°C
Relative air humidity5 - 95 % Non-condensing
Protection classIII
Overvoltage categoryII
Ambient temperature-20°C – 50°C
Note on ambient temperatureObserve ambient temperature derating according to IEC 61131-2:2017
Nominal altitude of use above sea level<= 2000 m ASL (> 79.5 kPa)
Max. installation height3500m
Information on max. installation height> 2000 m ASL (< 79.5 kPa) Observe ambient temperature derating according to IEC 61131-2:2017
Product weight1245g
Electrical actuationFieldbus
Communication interface, protocolAP
Type of mountingwith through-hole for M6 screw
Note on materialsRoHS-compliant Halogen-free Free of phosphoric acid ester
Cover materialZinc die-cast metal, powder-coated
Seals materialNBR PUR
Housing materialAluminum
Material of screwsSteel, nickel-plated
Manufacturer ID8154036

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp