- OT1600U02
ABB OT1600U02 is a two-pole, front-operated isolating switch with a 1600 A ampere rating and a conventional thermal current (Ithe) of 1600 A fully enclosed. It is rated 1000 V in the main circuit and 600 V maximum operating voltage per UL/CSA, with a 12 kV rated impulse withstand voltage and a 50 kA short-time withstand current for 1 s. Terminals are lug type, line terminals may be top-in/bottom-out or bottom-in/top-out, and tightening torque is 56 N·m per IEC 60947-1 or 500 in·lb per UL/CSA. Dimensions are 365 mm wide, 546 mm high, and 335 mm deep; net weight is 38.4 kg. Front degree of protection is IP00, pollution degree 3, base mounting, mechanical durability 2500 operations. Handle and shaft are not included. Standards: UL 98 / CSA C22.2 NO.4.
- OT1600U02P
The ABB OT1600U02P is a 2-pole, front-operated isolating switch with base mounting. It has a conventional thermal current (Ithe) of 1600 A fully enclosed and an ampere rating of 1600 A. Rated operational voltage of the main circuit is 1000 V, with a rated impulse withstand voltage (Uimp) of 12 kV and a rated short-time withstand current (Icw) of 50 kA for 1 s. Maximum operating voltage per UL/CSA is 600 V. The switch is listed to UL 98 / CSA C22.2 NO.4. It includes a black handle and shaft, lug terminals, and lock capability. Mechanical durability is 2500 cycles. Dimensions are 365 mm wide, 546 mm high, and 335 mm deep; net weight is 39.1 kg. Front degree of protection is IP00, pollution degree 3.
- OT1600U03
ABB OT1600U03 is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Pollution Degree: 3, Product Net Width: 445 mm, and Product Net Height: 546 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT1600U03P
ABB OT1600U03P isolating switch, 3-pole, front-operated, base mounting. Rated operational voltage of the main circuit is 1000 V, with a rated impulse withstand voltage (Uimp) of 12 kV and conventional thermal current (Ithe) of 1600 A fully enclosed. Rated short-time withstand current (Icw) is 50 kA for 1 s. Maximum operating voltage UL/CSA is 600 V; ampere rating 1600 A. Power loss at rated operating conditions per pole is 96 W. Front degree of protection IP00, pollution degree 3. Lug terminals; tightening torque acc. IEC 60947-1 56 N·m and 500 in·lb UL/CSA. Dimensions 445 mm wide, 546 mm high, 335 mm deep; net weight 54.4 kg. Standards: UL 98 / CSA C22.2 NO.4. Handle and shaft included, black handle, lockable.
- OT1600U04
ABB OT1600U04 is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Pollution Degree: 3, Product Net Width: 570 mm, and Product Net Height: 546 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT1600U04P
The ABB OT1600U04P is a four-pole, front-operated isolating switch with base mounting. It is rated 1600 A conventional thermal current (fully enclosed) and 1000 V rated operational voltage in the main circuit, with a 12 kV rated impulse withstand voltage and 50 kA rated short-time withstand current for 1 s. The fourth pole is switched, simultaneous function, mounted on the right side. Terminals are lug type, line terminals top in/bottom out or bottom in/top out, tightened to 56 N·m per IEC 60947-1 or 500 in·lb per UL/CSA. Maximum operating voltage UL/CSA is 600 V. Mechanical durability is 2500 operations. Dimensions are 570 mm wide, 546 mm high, and 335 mm deep; net weight 69.6 kg. Standards: UL 98 / CSA C22.2 NO.4. Front degree of protection IP00; pollution degree 3. Handle and shaft included, black handle, lockable.
- OT1600U12
ABB OT1600U12 isolating switch, manufacturer ID 1SCA144200R1001. Three-pole, front-operated, base-mounting non-fusible switch with conventional thermal current 1600 A fully enclosed and rated operational voltage 1000 V in the main circuit. Rated impulse withstand voltage is 12 kV; power loss is 96 W per pole at rated operating conditions. Pollution degree 3, front degree of protection IP00. Mechanical durability is 2500 operations. Line terminals may be configured top in - bottom out or bottom in - top out. Dimensions are 445 mm wide, 546 mm high, and 335 mm deep; net weight 53.7 kg. Handle and shaft are not included. No lock type is specified.
- OT1600U12P
ABB OT1600U12P isolating switch, 3-pole, front-operated, base mounting. Rated operational voltage of the main circuit is 1000 V, with a rated impulse withstand voltage of 12 kV and conventional thermal current of 1600 A fully enclosed. Rated short-time withstand current is 50 kA for 1 s. Maximum operating voltage UL/CSA is 600 V, and the ampere rating is 1600 A. The unit uses lug terminals with a tightening torque of 56 N·m per IEC 60947-1 and 500 in·lb per UL/CSA. Dimensions are 445 mm wide, 546 mm high, and 335 mm deep; net weight is 54.4 kg. Front degree of protection is IP00, pollution degree 3. Mechanical durability is 2500 operations. Standards: UL 98 / CSA C22.2 NO.4.