- OT125GAUC3AZ
The ABB OT125GAUC3AZ is a 3-pole front-operated switch disconnector supplied in an MSC-type steel sheet enclosure. It is rated for a conventional thermal current (Ithe) of 125 A fully enclosed, with screw clamp main circuit connections accepting 10 to 70 mm² and a PE terminal for two conductors of 10 to 70 mm². The enclosure provides IP65 protection according to IEC 60529 and housing impact resistance of IK09, with pollution degree 3. Cable entry is bottom/bottom, with blank or 2xC-flange outlets and knock-outs of 10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. A red/yellow pistol handle is fitted. Up to two NO and two NC auxiliary contacts can be mounted; one NO and one NC are mounted. No neutral terminal is included. Dimensions are 400 mm wide, 400 mm high, and 230 mm deep; net weight is 14.5 kg.
- OT125GAUC3TZ
The ABB OT125GAUC3TZ is a 3-pole isolating switch with a conventional thermal current (Ithe) of 125 A in the fully enclosed condition. It has a rated insulation voltage of 750 V and is supplied in an MSC-type steel sheet enclosure measuring 400 mm wide, 400 mm high, and 230 mm deep, with a net weight of 14.5 kg. The enclosure provides IP65 protection according to IEC 60529 and an impact resistance rating of IK09. Cable entry is bottom/bottom, with screw clamp connections for 10 to 70 mm² main circuit conductors and a PE terminal for two conductors of 10 to 70 mm². The pistol handle is black. One NO and one NC auxiliary contact are mounted, with space for up to two NO and two NC. No neutral terminal is included.
- OT125GAUC6AZ
ABB OT125GAUC6AZ is an isolating switch supplied in an MSC-type steel sheet enclosure. Its conventional thermal current (Ithe) is 125 A fully enclosed. The enclosure is rated IP65 according to IEC 60529 and has a housing impact resistance rating of IK09, with pollution degree 3. Dimensions are 400 mm wide, 600 mm high, and 230 mm deep; net weight is 21.31 kg. The main circuit uses screw clamp connections for cable cross-sections of 10 to 70 mm², with a PE terminal of 4 pc, 10 to 70 mm². Cable entry is bottom/bottom, with blank or 2xC-flange outlets and knock-outs of 10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. A red/yellow pistol handle is fitted. Mounted auxiliary contacts are 1 NO and 1 NC, with a maximum of 2 NO and 2 NC. No neutral terminal is included.
- OT125GAUC6TZ
ABB OT125GAUC6TZ is an enclosed switch-disconnector supplied under manufacturer ID 1SCA148495R1001. The steel sheet MSC enclosure measures 400 mm wide, 600 mm high, and 230 mm deep, with a net weight of 21.31 kg. It provides IP65 protection according to IEC 60529 and an impact resistance rating of IK09, with pollution degree 3. Conventional thermal current (Ithe) is 125 A fully enclosed. The main circuit uses screw clamp connections for 10 to 70 mm² cable, plus a PE terminal with four 10 to 70 mm² points. Cable entry is bottom/bottom, with blank or 2xC-flange outlets and knock-outs of 10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. A black pistol handle is fitted. Mounted auxiliary contacts are 1 NO and 1 NC, with space for up to 2 NO and 2 NC. No neutral terminal is included.
- OT125GAUM3TZ
ABB OT125GAUM3TZ is a three-pole isolating switch supplied in an MSC steel sheet enclosure with a black pistol handle. The enclosure provides IP65 protection according to IEC 60529 and IK09 impact resistance. Conventional thermal current (Ithe) is 125 A fully enclosed, with a pollution degree of 3. Main circuit connection uses screw clamps for 10 to 70 mm² conductors, plus a two-piece PE terminal for 10 to 70 mm². Cable entry is bottom/bottom, with knock-outs of 2x63.5 mm, 2x50.5 mm, 2x40.5 mm, 25.5 mm, and 20.5 mm. Mounted auxiliary contacts are 1 NO and 1 NC, with up to 2 NO and 2 NC supported. Mechanical durability is 20000 operations. Net dimensions are 400 mm wide, 600 mm high, and 230 mm deep; net weight is 21.31 kg.
- OT125GAUR3AZ
The ABB OT125GAUR3AZ is a 3-pole isolating switch supplied in an MSC steel sheet enclosure. It is base mounted and front operated with a red/yellow pistol handle. The conventional thermal current (Ithe) is 125 A fully enclosed. The enclosure provides IP65 protection according to IEC 60529 and IK09 impact resistance, with pollution degree 3. Main circuit connection is by screw clamp for 10 to 70 mm², plus a PE terminal with two 10 to 70 mm² connections. Cable entry is bottom/bottom, with blank or 4x ring-flange outlets and knock-outs of 3x10 mm, 12.5 mm, 20.5 mm, 25.5 mm, and 32.5 mm. Mounted auxiliary contacts are 1 NO and 1 NC; up to 2 NO and 2 NC can be fitted. No neutral terminal is included. Dimensions are 400 mm width, 400 mm height, and 230 mm depth; net weight is 14.8 kg.
- OT125GAUR3TZ
The ABB OT125GAUR3TZ is a 3-pole front-operated non-fusible switch disconnector supplied under manufacturer ID 1SCA148442R1001. It is rated for a conventional thermal current (Ithe) of 125 A when fully enclosed. The enclosure is MSC type, made of steel sheet, with dimensions of 400 mm width, 400 mm height, and 230 mm depth, and a net weight of 14.8 kg. Degree of protection is IP65 according to IEC 60529, with housing impact resistance IK09 and pollution degree 3. Cable entry is bottom/bottom, with screw clamp connecting capacity of 10 to 70 mm² and a PE terminal of 2 pc, 10 to 70 mm². Mounted auxiliary contacts are 1 NO and 1 NC, with a maximum of 2 NO and 2 NC. A black pistol handle is fitted, and no neutral terminal is provided.
- OT125GAUR3TZ-L21
ABB OT125GAUR3TZ-L21 is a 3-pole isolating switch in an MSC-type steel sheet enclosure with a black pistol handle. It is front-operated and non-fusible, with screw terminals accepting 10 to 70 mm² cable and a tightening torque of 6 N·m per IEC 60947-1. Rated insulation voltage is 1000 V per IEC/EN 60664-1; conventional thermal current is 125 A fully enclosed. Rated operational current AC-22A and AC-23A is 125 A at 380 to 415 V, 500 V, and 690 V, with AC-23A rated power of 55 kW, 75 kW, and 110 kW respectively. Rated conditional short-circuit current is 24 kA, and short-circuit making capacity is 12 kA at 690 V. The enclosure provides IP65 per IEC 60529 and IK09 impact resistance. One NO and one NC auxiliary contact are mounted; up to two NO and two NC are supported. Mechanical durability is 20000 operations. Standards: IEC 60947-1, -3.