- AFC16-22-00-88
The ABB AFC16-22-00-88 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.303 kg. The main circuit is rated 690 V, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. The control circuit coil operates at 50 Hz 230 to 240 V or 60 Hz 240 to 260 V. Screw terminals accept rigid stranded main circuit conductors from 1 to 6 mm². It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- AFC16-30-01-34
ABB AFC16-30-01-34 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-1 is 30 A at 690 V at 40 °C and 60 °C, and 26 A at 70 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL171001R3401.
- AFC16-30-01-42
ABB AC contactor AFC16-30-01-42, manufacturer ID 1SBL171001R4201. It has three normally open main contacts and one normally closed auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 60 °C, and 10.5 A at 690 V and 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC16-30-01-51
ABB AFC16-30-01-51 AC contactor, manufacturer ID 1SBL171001R5101. It has three normally open main contacts and one normally closed auxiliary contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 60 °C, 15 A at 500 V, and 10.5 A at 690 V. Rated operational power AC-3 is 9 kW at 415 V and 7.5 kW at 380/400 V. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.298 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-01-80
ABB AFC16-30-01-80 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Screw terminals.
- AFC16-30-01-81
ABB AFC16-30-01-81 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.309 kg. The main and auxiliary circuits are rated 690 V, with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-1 is 30 A at 690 V at 40 °C and 60 °C, and 26 A at 70 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC16-30-01-84
ABB AFC16-30-01-84 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.306 kg. The contactor is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. Per IEC 60947-4-1, AC-3 rated operational power is 7.5 kW at 380/400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V, at 60 °C. AC-3 rated operational current is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC16-30-01-85
The ABB AFC16-30-01-85 is a 3-pole AC contactor with one normally closed auxiliary contact and no normally open auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-1 is 30 A at 690 V at both 40 °C and 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V and 10.5 A at 690 V, both at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.