- AFC09-30-10K-88
The ABB AFC09-30-10K-88 is an AC contactor with manufacturer ID 1SBL131005R8810. It has three normally open main contacts and one normally open auxiliary contact, with no normally closed contacts. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.311 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 415 V and 440 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC09-40-00-34
ABB AC contactor AFC09-40-00-34, manufacturer ID 1SBL131201R3400, with four normally open main contacts and no auxiliary contacts. Main circuit rated operational voltage is 690 V at 50/60 Hz. Rated operational current AC-1 is 25 A at 690 V and 40 °C or 60 °C, and 22 A at 70 °C. Rated operational current AC-3 is 9 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 415 V, 440 V, and 380/400 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. Dimensions are 45 mm wide, 77 mm deep, 86 mm high; weight 0.298 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC09-40-00-42
ABB AC contactor AFC09-40-00-42, manufacturer ID 1SBL131201R4200, is a 4NO line contactor with no auxiliary contacts. It is rated 690 V in the main circuit at 50/60 Hz, with AC-1 rated operational current of 25 A at 690 V and 40 °C or 60 °C, and 22 A at 70 °C. AC-3 ratings include 9 A at 415 V, 440 V, and 380/400 V, 9.5 A at 500 V, and 7 A at 690 V. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.298 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC09-40-00-80
The ABB AFC09-40-00-80 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 25 A at 690 V and 40 °C or 60 °C, and 22 A at 70 °C. AC-3 ratings include 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC09-40-00-81
The ABB AFC09-40-00-81 is an AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.309 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 25 A at 690 V and 40 °C or 60 °C, and 22 A at 70 °C. Rated operational current AC-3 is 9 A at 415 V and 60 °C, and rated operational power AC-3 is 4 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC09-40-00-84
ABB AFC09-40-00-84 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, weighing 0.306 kg. The main circuit is rated 690 V at 50/60 Hz; the control circuit is rated 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 25 A at 690 V and 40 °C or 60 °C, and 22 A at 70 °C. AC-3 ratings include 9 A at 415 V and 7 A at 690 V, both at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC09-40-00-85
ABB 4-pole AC contactor, display model AFC09-40-00-85, manufacturer ID 1SBL131201R8500. It has four normally open main contacts and no auxiliary contacts. Main circuit rated operational voltage is 690 V at 50/60 Hz. Rated operational current AC-1 is 25 A at 690 V and 40 °C or 60 °C, and 22 A at 70 °C. Rated operational current AC-3 is 9 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, and 7 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 415 V, 440 V, and 380/400 V, and 5.5 kW at 500 V and 690 V. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; weight is 0.298 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC09-40-00-86
The ABB AFC09-40-00-86 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 25 A at 690 V and 40 °C or 60 °C, and 22 A at 70 °C. AC-3 ratings include 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.