- AFC09-30-01-88
The ABB AFC09-30-01-88 is a 3-pole AC contactor with three normally open main contacts and one normally closed built-in auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.303 kg. Per IEC/EN 60947-4-1, AC-3 rated operational power is 4 kW at 415 V and 440 V, 5.5 kW at 500 V and 690 V, 4 kW at 380/400 V, and 2.2 kW at 220/230/240 V. Rated operational voltage is 690 V for main and auxiliary circuits, with 50/60 Hz rated frequency. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC09-30-01K-34
ABB AFC09-30-01K-34 is an AC contactor, manufacturer ID 1SBL131005R3401. It has three normally open main contacts and one normally closed auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, with a net weight of 0.306 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 415 V and 440 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC09-30-01K-42
The ABB AFC09-30-01K-42 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Corresponding AC-3 rated power is 4 kW at 415 V, 440 V, and 380/400 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC09-30-01K-51
ABB AFC09-30-01K-51 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. The contactor is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Corresponding AC-3 rated operational power is 4 kW at 415 V, 440 V, and 380/400 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC09-30-01K-80
The ABB AFC09-30-01K-80 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It uses push-in terminals and measures 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.306 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Corresponding AC-3 rated power is 4 kW at 415 V and 440 V, and 5.5 kW at 500 V and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC09-30-01K-81
ABB AFC09-30-01K-81 is an AC contactor with manufacturer ID 1SBL131005R8101. It has three normally open main contacts and one normally closed auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, with a net weight of 0.317 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 9 A at 415 V and 4 kW at 415 V. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC09-30-01K-84
The ABB AFC09-30-01K-84 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.314 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC09-30-01K-85
The ABB AFC09-30-01K-85 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Corresponding AC-3 rated operational power is 4 kW at 415 V and 440 V, and 5.5 kW at 500 V and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.