- AF80-30-11-11
The ABB AF80-30-11-11 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 82 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.26 kg. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. Rated operational current AC-3 is 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 37 kW at 400 V and 45 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.
- AF80-30-11-13
The ABB AF80-30-11-13 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 82 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.21 kg. The control circuit accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Rated operational current AC-3 is 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 37 kW at 400 V and 45 kW at 415 V, 440 V, 500 V, and 690 V. It complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80-30-22-11
The ABB AF80-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 70 mm wide, 149 mm deep, and 125.5 mm high, and weighs 1.27 kg. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. Rated operational current AC-3 is 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 degrees C. Rated operational power AC-3 is 45 kW at 415 V, 440 V, 500 V, and 690 V, and 37 kW at 380/400 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.
- AF80-30-22-12
The ABB AF80-30-22-12 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. It measures 70 mm wide, 149 mm deep, and 125.5 mm high, and weighs 1.27 kg. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. AC-3 ratings include 80 A at 415 V and 37 kW at 400 V, both at 60 °C. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80-30-22-13
The ABB AF80-30-22-13 is an AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated 80 A at 415 V and 440 V in AC-3 at 60 °C, with rated operational power of 37 kW at 400 V and 45 kW at 415 V, 440 V, 500 V, and 690 V. The control circuit accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Screw terminals accept main-circuit conductors from 6 to 70 mm² rigid stranded. It mounts on TH35-15 DIN rail or with two M4 or M6 screws. Applicable standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF80-30-22-14
The ABB AF80-30-22-14 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 70 mm wide, 149 mm deep, and 125.5 mm high, and weighs 1.22 kg. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. Rated operational current AC-3 is 80 A at 380/400 V and 415 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 37 kW at 380/400 V and 45 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.
- AF80-40-00-11
The ABB AF80-40-00-11 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.49 kg. The main circuit is rated 1000 V, with a rated impulse withstand voltage of 8 kV and an insulation voltage of 1000 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Conventional free-air thermal current is 125 A at 40 °C. AC-3 ratings include 80 A at 380/400 V and 37 kW at 380/400 V, both at 60 °C. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80-40-00-12
The ABB AF80-40-00-12 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.49 kg. The main circuit is rated 1000 V, with a rated impulse withstand voltage of 8 kV and a rated insulation voltage of 1000 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Conventional free-air thermal current is 125 A at 40 °C per IEC 60947-4-1. AC-1 rated operational current is 125 A at 690 V and 40 °C. AC-3 rated operational power is 37 kW at 380/400 V and 45 kW at 415/440/500/690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.