- NFC44EK-51
The ABB NFC44EK-51 is an intermediate relay with four auxiliary contacts NO and four auxiliary contacts NC, and no main contacts. It measures 45 mm wide, 110.5 mm deep, and 92.3 mm high, and weighs 0.359 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 400 to 415 V at 50 Hz and 480 V at 60 Hz, with coil consumption of 2.3 W. It conforms to IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC44EK-80
ABB NFC44EK-80 intermediate relay, manufacturer ID 1SBH131005R8044. It has four normally open and four normally closed auxiliary contacts, with no main contacts NC. Dimensions are 45 mm wide, 110.5 mm deep, 92.3 mm high, and 0.359 kg. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC44EK-81
ABB NFC44EK-81 intermediate relay, manufacturer ID 1SBH131005R8144. It has four auxiliary normally open contacts and four auxiliary normally closed contacts, with no main normally closed contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high; net weight 0.368 kg. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC44EK-84
The ABB NFC44EK-84 is an intermediate relay with four normally open and four normally closed auxiliary contacts and no main contacts. It measures 45 mm wide, 110.5 mm deep, and 92.3 mm high, and weighs 0.365 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA, with rated impulse withstand voltage of 6 kV. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC44EK-85
ABB NFC44EK-85 intermediate relay, manufacturer ID 1SBH131005R8544. It has four auxiliary contacts NO and four auxiliary contacts NC, with no main contacts. Rated operational voltage is 690 V for both auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Coil consumption is 2.3 W, with rated control circuit voltage 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Dimensions are 45 mm width, 110.5 mm depth, 92.3 mm height, and 0.359 kg net weight. Push-in spring terminals accept rigid 1 to 2.5 mm² and flexible 0.5 to 2.5 mm² conductors, stripping length 10 mm. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC44EK-86
The ABB NFC44EK-86 is an intermediate relay with four normally open and four normally closed auxiliary contacts, and no main contacts. It measures 45 mm wide, 110.5 mm deep, and 92.3 mm high, and weighs 0.359 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and IEC 60947-5-1, and 600 V per UL/CSA. Rated impulse withstand voltage is 6 kV. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC44EK-88
ABB NFC44EK-88 intermediate relay, manufacturer ID 1SBH131005R8844. It has four normally open and four normally closed auxiliary contacts, with no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high; net weight 0.36 kg. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz; coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC51/11-34
ABB NFC51/11-34 intermediate relay, manufacturer ID 1SBH131001R3459. It has no main contacts (0 NO, 0 NC) and carries 6 auxiliary NO and 2 auxiliary NC contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high, with a net weight of 0.358 kg. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 175 V at 50 Hz and 208 V at 60 Hz, with coil consumption of 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.