- NFC22EK-86
The ABB NFC22EK-86 is an intermediate relay with 2 NO and 2 NC auxiliary contacts and no main contacts. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.306 kg. Rated operational voltage is 690 V for both auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated impulse withstand voltage is 6 kV. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14. Manufacturer ID: 1SBH131005R8622.
- NFC22EK-88
ABB NFC22EK-88 intermediate relay, manufacturer ID 1SBH131005R8822. It has two normally open and two normally closed auxiliary contacts, with no main contacts NC. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight 0.311 kg. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC31E-34
ABB NFC31E-34 intermediate relay, manufacturer ID 1SBH131001R3431. It has no main contacts and four auxiliary contacts: three normally open and one normally closed. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.3 kg. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC31E-51
ABB NFC31E-51 intermediate relay, manufacturer ID 1SBH131001R5131. It has 3 auxiliary contacts NO and 1 auxiliary contact NC, with no main contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.3 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC31E-80
The ABB NFC31E-80 is an intermediate relay with 3 normally open and 1 normally closed auxiliary contacts, no main contacts, and screw terminals. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.3 kg. The auxiliary circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 degrees C. The control circuit coil is rated 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz, with 2.3 W coil consumption. It mounts on TH35-15 or TH35-7.5 DIN rail according to IEC 60715, or on two M4 screws placed diagonally.
- NFC31E-81
ABB NFC31E-81 intermediate relay, manufacturer ID 1SBH131001R8131. It has 3 normally open and 1 normally closed auxiliary contact, with no main contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.309 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Coil voltage is 24 V at 50 Hz and 60 Hz, coil consumption 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC31E-84
ABB NFC31E-84 intermediate relay, manufacturer ID 1SBH131001R8431. It has 3 normally open and 1 normally closed auxiliary contacts, with no main contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.306 kg. Rated operational voltage for the auxiliary circuit is 690 V, with a rated frequency of 50/60 Hz for auxiliary, control, and main circuits. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC31E-85
ABB NFC31E-85 intermediate relay, manufacturer ID 1SBH131001R8531. It has three normally open and one normally closed auxiliary contact, with no main contacts. Auxiliary circuit rated operational voltage is 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Coil consumption is 2.3 W; rated control circuit voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Maximum mechanical switching frequency is 6000 cycles per hour. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; weight 0.3 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.