- NFC80E-86
ABB NFC80E-86 intermediate relay, manufacturer ID 1SBH131001R8680. It has eight auxiliary contacts, all normally open (8 NO, 0 NC), and no main contacts. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated control circuit voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.351 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC80E-88
ABB NFC80E-88 intermediate relay, manufacturer ID 1SBH131001R8880. It has eight auxiliary contacts NO, no auxiliary or main contacts NC, and measures 45 mm wide, 110.5 mm deep, and 86 mm high, weighing 0.352 kg. Auxiliary circuit rated operational voltage is 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC80EK-34
The ABB NFC80EK-34 is an intermediate relay with eight normally open auxiliary contacts and no main contacts. It measures 45 mm wide, 110.5 mm deep, and 92.3 mm high, and weighs 0.359 kg. The relay is rated for auxiliary and main circuit operational voltages of 690 V at 50/60 Hz, with a conventional free-air thermal current of 16 A according to IEC 60947-5-1 at 40 °C. Coil consumption is 2.3 W, with a rated control circuit voltage of 175 V at 50 Hz and 208 V at 60 Hz. It conforms to IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC80EK-42
ABB NFC80EK-42 intermediate relay, manufacturer ID 1SBH131005R4280. It has eight auxiliary contacts (8 NO, 0 NC) and no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high, with a net weight of 0.359 kg. Rated operational voltage is 690 V for both auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 230 to 240 V at 50 Hz and 277 V at 60 Hz, with coil consumption of 2.3 W. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC80EK-80
ABB NFC80EK-80 intermediate relay, manufacturer ID 1SBH131005R8080. It has eight auxiliary contacts NO, no auxiliary or main contacts NC, and measures 45 mm wide, 110.5 mm deep, and 92.3 mm high, weighing 0.359 kg. Rated operational voltage is 690 V for both auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W, with rated control circuit voltage 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC80EK-81
ABB NFC80EK-81 intermediate relay, manufacturer ID 1SBH131005R8180. It has 8 normally open auxiliary contacts and no normally closed contacts. The control circuit is rated 24 V at 50 Hz and 60 Hz, with coil consumption 2.3 W. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high; net weight 0.368 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC80EK-84
ABB NFC80EK-84 intermediate relay, manufacturer ID 1SBH131005R8480. It has eight auxiliary contacts NO, no auxiliary or main contacts NC, and measures 45 mm wide, 110.5 mm deep, and 92.3 mm high, weighing 0.365 kg. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC80EK-85
ABB NFC80EK-85 intermediate relay, manufacturer ID 1SBH131005R8580. It has eight auxiliary contacts (8 NO, 0 NC) and no main contacts. Dimensions are 45 mm wide, 110.5 mm deep, and 92.3 mm high, with a net weight of 0.359 kg. Rated operational voltage is 690 V for both auxiliary and main circuits at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz, with coil consumption of 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.