Industrial Automation Parts. Prompt replies from real people.

ABB UAF95-30-00RA-72 3-Phase Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the ABB UAF95-30-00RA-72?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB UAF95-30-00RA-72 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
UAF95-30-00RA-72
Material Number
1SFL437024R7200
Manufacturer
ABB
Product ID
88498

Get a Free Quote

Request pricing and availability for UAF95-30-00RA-72.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
1.8 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 145 A (690 V) 55 °C 135 A (690 V) 70 °C 115 A
Rated Operational Power AC-3 (Pe)
(380 / 400 V) 45 kW
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour (AC-2 / AC-4) 150 cycles per hour (AC-3) 300 cycles per hour
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
See all specifications

Product Highlights

  1. Capacitor Switching Duty: Rated operational power AC-6b up to 80 kvar at 690 V and 65 kvar at 400/415 V, 50/60 Hz
  2. Main Contacts: 3 NO main contacts, no NC main contacts and no auxiliary contacts
  3. Current Ratings: Conventional free-air thermal current 145 A at 40 °C, AC-1 145 A at 40 °C and AC-3 96 A at 380/400 V, 55 °C
  4. Coil and Control: Rated control circuit voltage 20 to 60 V DC, coil operating limits 0.85 to 1.1 x Uc at up to 70 °C, DC holding consumption 2 W
  5. Mechanical Durability: 10 million operating cycles with maximum mechanical switching frequency of 300 cycles per hour
  6. Main Terminals: M8 hexagon socket screws with single connector, accepting rigid 2 x 6 to 65 mm² and flexible cable with end 1 x 10 to 70 mm²
  7. Insulation and Impulse Withstand: Rated insulation voltage 1000 V according to IEC 60947-4-1 and 600 V according to UL/CSA, rated impulse withstand voltage 8 kV
  8. Mounting and Environment: Operates without derating up to 3000 m altitude and from -40 to 70 °C without thermal overload relay
UAF95-30-00RA-72

Product Information

Technical Specifications

Specifications for UAF95-30-00RA-72

ParameterValue
Product Net Width90 mm
Product Net Depth / Length155.6 mm
Product Net Height170 mm
Product Net Weight1.8 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Rated Operational VoltageMain Circuit 1000 V
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 145 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 145 A (690 V) 55 °C 135 A (690 V) 70 °C 115 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 96 A (440 V) 55 °C 93 A (500 V) 55 °C 80 A (690 V) 55 °C 65 A (1000 V) 55 °C 30 A (380400 V) 55 °C 96 A (220230240 V) 55 °C 96
Rated Operational Power AC-3 (Pe)(380 / 400 V) 45 kW
Rated Operational Power AC-6b (Pe)(230240 V) 40 °C, 5060 Hz 35 kvar (230240 V) 55 °C, 5060 Hz 35 kvar (230240 V) 70 °C, 5060 Hz 30 kvar (400415 V) 40 °C, 5060 Hz 65 kvar (400415 V) 70 °C, 5060 Hz 55 kvar (400415 V) 55 °C, 5060 Hz 65 kvar (440 V) 40 °C, 5060 Hz 65 kvar (440 V) 55 °C, 5060 Hz 65 kvar (440 V) 70 °C, 5060 Hz 55 kvar (500550 V), 40 °C, 5060 Hz 70 kvar (500550 V) 55 °C, 5060 Hz 70 kvar (500550 V) 70 °C, 5060 Hz 60 kvar (690 V) 40 °C, 5060 Hz 80 kvar (690 V) 55 °C, 5060 Hz 80 kvar (690 V) 70 °C, 5060 Hz 70 kvar
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour (AC-2 / AC-4) 150 cycles per hour (AC-3) 300 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Mechanical Durability10 million
ParameterValue
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)DC Operation 20 ... 60 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A Holding at Max. Rated Control Circuit Voltage DC 2 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·A Pull-in at Max. Rated Control Circuit Voltage DC 400 V·A
Operate TimeBetween Coil De-energization and NC Contact Closing 60 ... 130 ms Between Coil De-energization and NO Contact Opening 55 ... 125 ms Between Coil Energization and NC Contact Opening 27 ... 77 ms Between Coil Energization and NO Contact Closing 30 ... 80 ms
Connecting Capacity Main CircuitBar 30 mm² Flexible with Cable End 1 x 10 ... 70 mm² Rigid 2 x 6 ... 65 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 2x0.75 ... 2.5 mm² Solid 1 x 1 ... 4 mm² Stranded 2 x 1 .... 4 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main PolesM8 hexagon socket screw with single connector
Terminal TypeCable Clamp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
Horsepower Rating UL/CSA(200 V AC) Three Phase 30 hp (208 V AC) Three Phase 30 hp (220 ... 240 V AC) Three Phase 30 hp (440 ... 480 V AC) Three Phase 60 hp (550 ... 600 V AC) Three Phase 75 hp
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -60 ... +80 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
Object Classification CodeQ
ETIM 7EC001079 - Capacitor contactor
ETIM 8EC001079 - Capacitor contactor
ETIM 9EC001079 - Capacitor contactor
eClassV11.0 : 27371006
UNSPSC39121529
IDEA Granular Category Code (IGCC)4756 >> Capacitor magnet contactor
Manufacturer ID1SFL437024R7200

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.