- AFC38-30-00-86
ABB AFC38-30-00-86 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.351 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 38 A at 415 V and 440 V, 33 A at 500 V, and 24 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 415 V and 380/400 V, 22 kW at 440 V, 500 V, and 690 V, and 11 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID 1SBL291001R8600.
- AFC38-30-00-88
The ABB AFC38-30-00-88 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.352 kg. The main circuit is rated 690 V, with a control and main circuit frequency of 50/60 Hz. Rated operational current AC-3 is 38 A at 415 V and 440 V, 33 A at 500 V, and 24 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 415 V and 380/400 V, and 22 kW at 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC38-30-00K-34
ABB AFC38-30-00K-34 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.35 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 50 A at 40 °C. Rated operational current AC-3 is 38 A at 415 V and 440 V, 33 A at 500 V, and 24 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 415 V and 22 kW at 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC38-30-00K-42
The ABB AFC38-30-00K-42 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.35 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 38 A at 380/400 V and 415 V, 33 A at 500 V, and 24 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 415 V, 22 kW at 440 V, 500 V, and 690 V, and 11 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC38-30-00K-80
The ABB AFC38-30-00K-80 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.35 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 38 A at 415 V and 440 V, 33 A at 500 V, and 24 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 415 V and 380/400 V, and 22 kW at 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC38-30-00K-81
ABB AFC38-30-00K-81 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.359 kg. The main circuit is rated 690 V, with control and main circuit frequencies of 50/60 Hz. Rated operational current AC-3 is 38 A at 415 V and 440 V, 33 A at 500 V, and 24 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 415 V and 380/400 V, and 22 kW at 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC38-30-00K-84
ABB AFC38-30-00K-84 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.356 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 38 A at 380/400 V and 415 V, 33 A at 500 V, and 24 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 415 V, 22 kW at 440 V, 500 V, and 690 V, and 11 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC38-30-00K-85
ABB AFC38-30-00K-85 is an AC contactor, manufacturer ID 1SBL291005R8500. It has three normally open main contacts and no auxiliary contacts. Dimensions are 45 mm wide, 86 mm deep, and 92.3 mm high, with a net weight of 0.35 kg. Main circuit rated operational voltage is 690 V, with a rated frequency of 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 50 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 38 A at 415 V and 60 °C, and rated operational power AC-3 is 18.5 kW at 415 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.