- AF460-30-11-68
The ABB AF460-30-11-68 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Rated operational current AC-3 is 460 A at 380/400 V, 415 V, 440 V, 500 V, and 220/230/240 V at 55 °C, and 400 A at 690 V at 55 °C. Rated operational power AC-3 is 250 kW at 380/400 V, 415 V, and 440 V, 315 kW at 500 V, and 355 kW at 690 V. The control circuit is rated 24 to 60 V DC. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg. Mechanical durability is 3 million operations.
- AF460-30-11-69
The ABB AF460-30-11-69 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz, with conventional free-air thermal current 700 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 460 A at 415 V and 55 °C, and rated operational power AC-3 is 250 kW at 415 V. The control circuit operates at 48 to 130 V for 50 Hz, 60 Hz, and DC. Dimensions are 186 mm width, 216 mm depth, and 278 mm height, with 10.6 kg net weight. Main terminals are bars; coil terminals are IP20 and main terminals IP00 according to IEC 60529, IEC 60947-1, and EN 60529.
- AF460-30-11-70
The ABB AF460-30-11-70 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz, with a rated impulse withstand voltage of 8 kV. AC-3 rated operational power is 250 kW at 415 V, 440 V, and 380/400 V, 315 kW at 500 V, 355 kW at 690 V, and 280 kW at 1000 V. The control circuit voltage range is 100 to 250 V for 50 Hz, 60 Hz, and DC operation. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high, with a net weight of 10.6 kg. Main circuit terminals are bars. Mechanical durability is 3 million operations.
- AF460-30-11-71
The ABB AF460-30-11-71 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Main circuit rated operational voltage is 1000 V at 50/60 Hz. Rated operational power AC-3 is 250 kW at 415 V and 440 V, 315 kW at 500 V, 355 kW at 690 V, and 280 kW at 1000 V. Conventional free-air thermal current is 700 A according to IEC 60947-4-1 at 40 °C. Coil control voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg. Main terminals are bars; main terminals IP00, coil terminals IP20.
- AF460-30-22 100-250V
Product identification: ABB AF460-30-22 100-250V. The ABB AF460-30-22 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The control circuit accepts 100 to 250 V DC, and the main circuit is rated 1000 V. Rated operational current AC-3 is 460 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, 400 A at 690 V, and 200 A at 1000 V. Rated operational power AC-3 is 250 kW at 415 V and 440 V, 315 kW at 500 V, 355 kW at 690 V, and 280 kW at 1000 V. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high, with a net weight of 10.6 kg. Mechanical durability is 3 million operations, with a maximum mechanical switching frequency of 300 cycles per hour. Main circuit terminals are bars.
- AF460-30-22-68
The ABB AF460-30-22-68 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 186 mm wide, 216 mm deep, and 278 mm high, and weighs 10.6 kg. The main circuit is rated 1000 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 700 A at 40 °C. AC-3 rated operational current is 460 A at 415 V and 55 °C, with rated operational power of 250 kW at 415 V. AC-3 breaking capacity is 8 x Ie and making capacity is 10 x Ie. Maximum electrical switching frequency in AC-3 is 300 cycles per hour.
- AF460-30-22-69
The ABB AF460-30-22-69 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 700 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 460 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, and 400 A at 690 V at 55 °C. Rated operational power AC-3 is 250 kW at 415 V and 440 V, 315 kW at 500 V, and 355 kW at 690 V. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg.
- AF460-30-22-70
The ABB AF460-30-22-70 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. It measures 186 mm wide, 216 mm deep, and 278 mm high, and weighs 10.6 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 700 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 460 A at 415 V and 55 °C, and rated operational power AC-3 is 250 kW at 415 V. Rated making capacity is 10 x Ie AC-3 and breaking capacity is 8 x Ie AC-3. Short-circuit protection uses gG type fuses, 1.5 to 1.8 In A.