- AF12-30-01-14
The ABB AF12-30-01-14 is a block-type AC contactor with three normally open main contacts and one normally closed auxiliary contact. It uses screw terminals and measures 45 mm wide, 77 mm deep, and 86 mm high, weighing 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 400 V and 7.5 kW at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- AF12-30-01K-11
The ABB AF12-30-01K-11 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 690 V and a control circuit voltage of 24 to 60 V at 50/60 Hz, or 20 to 60 V DC. Rated operational current AC-3 is 12 A at 380/400 V and 415 V, and rated operational power AC-3 is 5.5 kW at 380/400 V and 415 V. The contactor uses push-in spring terminals and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or on 2 x M4 screws placed diagonally. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.285 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12-30-01K-12
ABB AF12-30-01K-12 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.285 kg. The contactor is rated 28 A at 690 V AC-1 at 40 °C and 60 °C, and 12 A at 220/230/240 V, 380/400 V, 415 V, and 440 V AC-3 at 60 °C. AC-3 power ratings include 3 kW at 220/230/240 V, 5.5 kW at 380/400 V, 415 V, and 440 V, and 7.5 kW at 500 V and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF12-30-01K-13
The ABB AF12-30-01K-13 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It has push-in spring terminals and measures 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.285 kg. Rated operational power AC-3 is 5.5 kW at 415 V and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Rated operational current AC-3 is 12 A at 415 V, 440 V, and 380/400 V, 12.5 A at 500 V, and 9 A at 690 V, at 60 °C. The contactor conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Rated insulation voltage is 690 V, rated impulse withstand voltage is 6 kV, and degree of protection is IP20.
- AF12-30-01K-14
The ABB AF12-30-01K-14 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It is rated 28 A at 690 V AC-1 at 40 °C and 60 °C, and 24 A at 70 °C. AC-3 ratings include 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, corresponding to 5.5 kW at 415 V and 440 V, and 7.5 kW at 500 V and 690 V. The control circuit accepts 250 to 500 V at 50 Hz, 60 Hz, or DC. Rated insulation voltage is 690 V and rated impulse withstand voltage is 6 kV. Terminals are push-in spring type. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.325 kg.
- AF12-30-10-11
The ABB AF12-30-10-11 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It has a rated operational voltage of 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. The rated operational current AC-1 is 28 A at 690 V and 40 °C, and AC-3 is 12 A at 415 V and 60 °C. Rated operational power AC-3 is 5.5 kW at 400 V and 7.5 kW at 500 V. The control circuit voltage is 24 to 60 V at 50/60 Hz and 20 to 60 V DC. It measures 45 mm wide, 77 mm deep, and 86 mm high, weighs 0.27 kg, and uses screw terminals. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12-30-10-12
ABB AF12-30-10-12 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 12 A at 415 V and 60 °C, and 9 A at 690 V and 60 °C. AC-3 rated power is 5.5 kW at 400 V and 7.5 kW at 500 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12-30-10-13
The ABB AF12-30-10-13 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, at 60 °C. Rated operational power AC-3 is 5.5 kW at 400 V, 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.