- AFC80-30-11-81
The ABB AFC80-30-11-81 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V and a maximum UL/CSA operating voltage of 600 V. AC-3 rated operational current is 80 A at 415 V and 440 V at 60 °C, with rated operational power of 45 kW at 415 V. The contactor uses screw terminals and mounts on TH35-15 (35 x 15 mm) DIN rail per IEC 60715, or on 2 x M4 or 2 x M6 screws placed diagonally. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1. Net dimensions are 87 mm wide, 119.5 mm deep, and 116 mm high; net weight is 1.25 kg.
- AFC80-30-11-84
The ABB AFC80-30-11-84 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It uses screw terminals. The main circuit is rated for 1000 V. Per IEC 60947-4-1, conventional free-air thermal current is 130 A at 40 °C. AC-3 ratings include 80 A at 415 V and 60 °C, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V. AC-3 power ratings include 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Dimensions are 87 mm wide, 119.5 mm deep, and 116 mm high; net weight is 1.25 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC80-30-11-85
ABB AFC80-30-11-85 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 87 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.25 kg. The main circuit is rated 1000 V. Conventional free-air thermal current is 130 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 80 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 60 °C, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC80-30-11-86
ABB AFC80-30-11-86 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 87 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.25 kg. The main circuit is rated 1000 V, with a rated frequency of 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 130 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 80 A at 380/400 V and 415 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC80-30-11-88
The ABB AFC80-30-11-88 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed built-in auxiliary contact. It measures 87 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.25 kg. Rated operational voltage for the main circuit is 1000 V. Conventional free-air thermal current is 130 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-1 is 125 A at 690 V and 40 °C. AC-3 ratings include 80 A at 415 V and 60 °C, and 25 A at 1000 V and 60 °C. It complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC80-40-00-34
ABB AFC80-40-00-34 is a 4-pole AC contactor, manufacturer ID 1SBL391201R3400, with four normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 119.5 mm deep, 116 mm high, and weighs 1.45 kg. Main circuit rated operational voltage is 1000 V at 50/60 Hz. Conventional free-air thermal current is 125 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 440 V, and 380/400 V at 60 °C, and 65 A at 500 V. Rated operational power AC-3 is 45 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC80-40-00-42
ABB AFC80-40-00-42 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 119.5 mm deep, and 116 mm high, weighing 1.45 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 125 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, and 49 A at 690 V at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC80-40-00-51
ABB AFC80-40-00-51 AC contactor, manufacturer ID 1SBL391201R5100. It has four normally open main contacts and no auxiliary contacts. Main circuit rated operational voltage is 1000 V; rated frequency is 50/60 Hz for main and auxiliary circuits. Conventional free-air thermal current is 125 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 80 A at 415 V, 440 V, and 380/400 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. AC-3 rated power is 45 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions: 90 mm wide, 119.5 mm deep, 116 mm high; 1.45 kg.