Industrial Automation Parts. Prompt replies from real people.

ABB AFC80-30-11-80 3-Pole Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the ABB AFC80-30-11-80?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB AFC80-30-11-80 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
AFC80-30-11-80
Material Number
1SBL391001R8011
Manufacturer
ABB
Product ID
87862

Get a Free Quote

Request pricing and availability for AFC80-30-11-80.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
1.25 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 125 A (690 V) 60 °C 100 A (690 V) 70 °C 85 A
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW (440 V) 45 kW (500 V) 45 kW (690 V) 45 kW (1000 V) 35 kW (380 / 400 V) 37 kW (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A for 0.1 s 140 A for 1 s 100 A
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour (AC-15) 1200 cycles per hour (AC-2 / AC-4) 150 cycles per hour (AC-3) 1200 cycles per hour (DC-13) 900 cycles per hour
See all specifications

Product Highlights

  1. Main Contacts: 3 normally open main contacts with no normally closed main contacts
  2. Auxiliary Contacts: 1 normally open plus 1 normally closed auxiliary contact
  3. Current Ratings: AC-1 rated operational current 125 A at 40 °C and 100 A at 60 °C at 690 V, with conventional free-air thermal current 130 A at 40 °C
  4. Power Ratings: AC-3 rated operational power 45 kW at 415 to 690 V, 37 kW at 380 to 400 V, and 22 kW at 220 to 240 V
  5. Coil and Mounting: Control circuit voltage 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz, with DIN rail TH35-15 or diagonal M4/M6 screw mounting
AFC80-30-11-80

Product Information

Technical Specifications

Specifications for AFC80-30-11-80

ParameterValue
Product Net Width87 mm
Product Net Depth / Length119.5 mm
Product Net Height116 mm
Product Net Weight1.25 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
Rated Operational VoltageMain Circuit 1000 V
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 125 A (690 V) 60 °C 100 A (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 80 A (440 V) 60 °C 80 A (500 V) 60 °C 65 A (690 V) 60 °C 49 A (1000 V) 60 °C 25 A (380400 V) 60 °C 80 A (220230240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)(415 V) 60 °C 80 A (440 V) 60 °C 80 A (500 V) 60 °C 65 A (690 V) 60 °C 49 A (380400 V) 60 °C 80 A (220230240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe)(415 V) 45 kW (440 V) 45 kW (500 V) 45 kW (690 V) 45 kW (1000 V) 35 kW (380400 V) 37 kW (220230240 V) 22 kW
Rated Operational Power AC-3e (Pe)(415 V) 45 kW (440 V) 45 kW (500 V) 45 kW (690 V) 45 kW (380400 V) 37 kW (220230240 V) 22 kW
Rated Operational Power AC-6b (Pe)(400415 V) 40 °C, 5060 Hz 48 kvar (400415 V) 70 °C, 5060 Hz 41 kvar (400415 V) 55 °C, 5060 Hz 48 kvar (500550 V), 40 °C, 5060 Hz 60 kvar (500550 V) 55 °C, 5060 Hz 60 kvar (500550 V) 70 °C, 5060 Hz 51 kvar (690 V) 40 °C, 5060 Hz 80 kvar (690 V) 55 °C, 5060 Hz 80 kvar (690 V) 70 °C, 5060 Hz 70 kvar
Rated Operational Current AC-15 (Ie)(500 V) NC 2
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A for 0.1 s 140 A for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour (AC-15) 1200 cycles per hour (AC-2 / AC-4) 150 cycles per hour (AC-3) 1200 cycles per hour (DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)(24 V) 6 A144 W (48 V) 2.8 A134 W (72 V) 1 A72 W (110 V) 1.1 A121 W (125 V) 0.55 A69 W (220 V) 0.27 A60 W (250 V) 0.27 A68 W (400 V) 0.15 A60 W (500 V) 0.13 A65 W (600 V) 0.1 A60 W
ParameterValue
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 8 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 220 ... 230 V 60 Hz 230 ... 240 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 20 V·A Average Pull-in Value 50 Hz 236 V·A Average Pull-in Value 60 Hz 260 V·A
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 21 ms Between Coil De-energization and NO Contact Opening 5 ... 16 ms Between Coil Energization and NC Contact Opening 3 ... 17 ms Between Coil Energization and NO Contact Closing 7 ... 22 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 6 ... 50 mm² Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² Rigid 1x 6 ... 70 mm² Rigid 2x 6 ... 50 mm² Rigid 1x 6 ... 70 mm² Rigid 2x 6 ... 50 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping LengthControl Circuit 10 mm Main Circuit 17 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal TypeScrew Terminals
NEMA Size3
Continuous Current Rating NEMA90 A
Horsepower Rating NEMA(200 V AC) Three Phase 25 Hp (230 V AC) Three Phase 30 Hp (460 V AC) Three Phase 50 Hp (575 V AC) Three Phase 50 Hp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 105 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 7-1/2 hp (200 ... 208 V AC) Three Phase 25 hp (220 ... 240 V AC) Three Phase 30 hp (240 V AC) Single Phase 15 hp (440 ... 480 V AC) Three Phase 60 hp (550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb Control Circuit 11 in·lb Main Circuit 53 in·lb
Ambient Air TemperatureClose to Contactor without Thermal O/L Relay -40 ... 70 °C Close to Contactor for Storage -60 ... +80 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: A 25 g Closed, Shock Direction: B1 25 g Closed, Shock Direction: B2 15 g Closed, Shock Direction: C1 25 g Closed, Shock Direction: C2 25 g Open, Shock Direction: B1 5 g
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
Manufacturer ID1SBL391001R8011

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp