- AF12-30-10K-11
ABB AF12-30-10K-11 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It operates on a control circuit of 24-60 V AC or 20-60 V DC at 50/60 Hz. Rated operational voltage is 690 V for both main and auxiliary circuits. Rated operational power AC-3 is 5.5 kW at 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Rated operational current AC-3 is 12 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 12.5 A at 500 V, and 9 A at 690 V. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight 0.285 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12-30-10K-12
ABB AF12-30-10K-12 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.285 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, at 60 °C. Rated operational power AC-3 is 5.5 kW at 415 V and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12-30-10K-13
The ABB AF12-30-10K-13 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.285 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. AC-3 ratings include 12 A at 415 V and 12.5 A at 500 V, with corresponding rated operational power of 5.5 kW at 415 V and 7.5 kW at 500 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL157005R1310.
- AF12-30-10K-13M
The ABB AF12-30-10K-13M is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.285 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, at 60 °C. Rated operational power AC-3 is 5.5 kW at 415 V and 440 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. It conforms to IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-16, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL157005M1310.
- AF12-30-10K-14
The ABB AF12-30-10K-14 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.325 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Corresponding AC-3 rated operational power is 5.5 kW at 415 V and 440 V, and 7.5 kW at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12-30-22-11
The ABB AF12-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a 690 V main and auxiliary circuit at 50/60 Hz. AC-3 ratings include 12 A at 415 V and 9 A at 690 V, with rated operational power of 5.5 kW at 400 V and 7.5 kW at 690 V. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C. Dimensions are 45 mm wide, 110.5 mm deep, and 86 mm high, weighing 0.32 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF12-30-22-12
The ABB AF12-30-22-12 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.32 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational power AC-3 is 5.5 kW at 400 V, 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. It uses screw terminals, mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, and is rated IP20 on main, auxiliary, and coil terminals.
- AF12-30-22-13
The ABB AF12-30-22-13 is an AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.32 kg. The contactor is rated 690 V for both main and auxiliary circuits at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 35 A at 40 °C. Rated operational current AC-3 is 12 A at 220/230/240 V, 380/400 V, 415 V, and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Corresponding AC-3 power ratings are 3 kW at 220/230/240 V, 5.5 kW at 380/400 V through 440 V, and 7.5 kW at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.