- OS800DS03K
ABB OS800DS03K is a three-pole fuse protector for base mounting, with a direct-mounted side-operated handle. The main circuit is rated 800 A; conventional free-air thermal current is 800 A at 40 °C, and conventional thermal current in a fully enclosed installation is 720 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It accepts NH3 fuses in the DIN fuse system. Line terminals may be connected top in/bottom out or bottom in/top out. Power loss is 75 W per pole at rated operating conditions. Pollution degree is 3. Net dimensions are 414 mm wide, 306 mm high, and 247 mm deep; net weight is 14.1 kg. Manufacturer ID: 1SCA108093R1001.
- OS800DS30
ABB fuse protector, model OS800DS30, manufacturer ID 1SCA108098R1001. This is a 3-pole, side-operated fusible switch for base mounting, using DIN NH3 fuse system. Main circuit rated current is 800 A. Conventional free-air thermal current is 800 A at 40 °C; conventional thermal current fully enclosed is 720 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. Power loss is 75 W per pole at rated operating conditions. Pollution degree 3. Line terminals may be top in/bottom out or bottom in/top out. Dimensions are 414 mm wide, 306 mm high, and 247 mm deep; net weight is 13.9 kg. Handle and shaft are not included.
- OS800DS30K
ABB OS800DS30K fuse protector, manufacturer ID 1SCA108099R1001. Three-pole, side-operated switch fuse for NH3 DIN fuse system, base mounting, with direct mounted handle included. Main circuit rated current 800 A. Conventional free-air thermal current 800 A at 40 °C; conventional thermal current 720 A fully enclosed. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 80 kA at 690 V. Power loss 75 W per pole at rated operating conditions. Pollution degree 3. Line terminals may be top in - bottom out or bottom in - top out. Dimensions: 414 mm width, 306 mm height, 247 mm depth; net weight 14.1 kg.
- OS800DS40F
The ABB OS800DS40F is a four-pole fuse switch disconnector for base mounting, side operated from the right side. It accepts NH3 DIN fuses and uses lug terminals 39 mm wide with a tightening torque of 50 to 75 N·m. Rated current is 800 A in the main circuit, with conventional free-air thermal current 800 A at 40 °C and enclosed thermal current 720 A. Rated operational voltage is 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 18 kA rms for 1 s. Power loss is 75 W per pole at rated operating conditions. Pollution degree 3. Standards: IEC 60947-3. Dimensions: 502 mm wide, 306 mm high, 247 mm deep; 16.8 kg. Handle and shaft are not included.
- OS800DS40FK
ABB OS800DS40FK fuse switch disconnector, four-pole, side-operated, base mounting. Main circuit rated current 800 A at 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV; pollution degree 3. Conventional free-air thermal current 800 A at 40 °C; conventional thermal current 720 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Fuse system DIN, fuse size NH3; fourth pole switched-fusible. Lug terminals, 39 mm wide, tightening torque 50 to 75 N·m. Power loss 75 W per pole at rated operating conditions. Direct-mounted handle included. Dimensions 502 x 306 x 247 mm; net weight 17 kg. Standard: IEC 60947-3.
- OS800DS40N2
ABB fuse protector, model OS800DS40N2, manufacturer ID 1SCA108103R1001. This four-pole, side-operated fuse switch disconnector uses NH3 DIN fuse system fuses and base mounting. Rated values include 800 A main circuit current, 690 V AC rated operational voltage, 1000 V rated insulation voltage, and 12 kV rated impulse withstand voltage. Conventional free-air thermal current is 800 A at 40 °C; fully enclosed thermal current is 720 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 18 kA rms for 1 s. Dimensions are 247 mm wide, 477 mm high, and 306 mm deep, with 15.9 kg net weight. Standards: IEC 60947-3. Handle and shaft are not included.
- OS800DS40N2K
The ABB OS800DS40N2K is a four-pole fuse protector with a base-mounted, side-operated direct handle. It accepts NH3 DIN fuses and uses lug terminals with a 39 mm terminal width and a tightening torque of 50 to 75 N·m. The main circuit is rated 800 A at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 800 A at 40 °C; fully enclosed conventional thermal current is 720 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 18 kA rms for 1 s. Power loss is 75 W per pole at rated operating conditions. It conforms to IEC 60947-3. Dimensions are 247 mm wide, 502 mm high, and 306 mm deep; net weight is 15.9 kg.
- OS800L02
The ABB OS800L02 is a two-pole fuse switch disconnector for base mounting, front operated with the operating mechanism on the left side. It accepts 800 A Class L fuses and is rated 800 A in the main circuit, with conventional free-air thermal current 800 A at 40 °C and 720 A fully enclosed. Rated insulation voltage is 1000 V, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current 80 kA at 690 V. It is rated 600 V AC, with AC-23A operational power of 250 kW at 220–240 V and 710 kW at 690 V. Standards: UL98 and IEC 60947-3. Dimensions are 255 mm wide, 306 mm high, and 233 mm deep; net weight 10.06 kg. Handle and shaft are not included.