- AF146-30-11B-32
The ABB AF146-30-11B-32 is a three-phase AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 138.5 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V, 500 V, and 690 V, and 45 kW at 220/230/240 V.
- AF146-30-11B-33
The ABB AF146-30-11B-33 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 142.5 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 1000 V and 50 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, and rated operational power AC-3 is 75 kW at 415 V. The manufacturer ID is 1SFL467002R3311.
- AF146-30-11B-34
The ABB AF146-30-11B-34 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 142.5 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, and rated operational power AC-3 is 75 kW at 415 V. Manufacturer ID 1SFL467002R3411.
- AF146-30-11B-42
The ABB AF146-30-11B-42 is a non-reversing, 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Manufacturer ID: 1SFL467002R4211.
- AF146-30-11B-43
The ABB AF146-30-11B-43 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 380/400 V, 415 V, and 440 V at 60 °C, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V. Rated operational power AC-3 is 75 kW at 380/400 V and 415 V, 90 kW at 440 V, 500 V, and 690 V, and 45 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg.
- AF146-30-22-11
The ABB AF146-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated 1000 V in the main circuit at 50/60 Hz, with AC-3 rated operational current of 146 A at 415 V and 55 °C, and AC-3 rated operational power of 75 kW at 415 V. Conventional free-air thermal current is 225 A per IEC 60947-4-1 at 40 °C. The coil accepts 24 to 60 V at 50 Hz, 24 to 60 V at 60 Hz, and 20 to 60 V DC. Terminals use double clamp connections. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg.
- AF146-30-22-12
The ABB AF146-30-22-12 is a 3-phase AC/DC operated IEC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Manufacturer ID: 1SFL467001R1222.
- AF146-30-22-13
The ABB AF146-30-22-13 is a 3-phase AC/DC operated contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, and rated operational power AC-3 is 75 kW at 415 V. Rated making capacity AC-3 is 10 x Ie; rated breaking capacity AC-3 is 8 x Ie. Manufacturer ID: 1SFL467001R1322.