- AFS26Z-30-22-30
The ABB AFS26Z-30-22-30 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 139.5 mm deep, and 86 mm high, and weighs 0.54 kg. The main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 26 A at 415 V and 440 V, 23 A at 500 V, and 17 A at 690 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 400 V and 15 kW at 440 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFS30-30-22-11
The ABB AFS30-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 119.5 mm deep, and 86 mm high, and weighs 0.36 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 50 A at 40 °C. AC-3 ratings include 32 A at 415 V and 21 A at 690 V, both at 60 °C, with 15 kW at 400 V and 18.5 kW at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFS30-30-22-13
The ABB AFS30-30-22-13 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 119.5 mm deep, and 86 mm high, and weighs 0.36 kg. The main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 32 A at 415 V and 60 °C, and 21 A at 690 V and 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFS305-30-12-11
ABB AFS305-30-12-11 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V, 440 V, and 380/400 V, 290 A at 500 V and 690 V, and 131 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 160 kW at 415 V, 440 V, and 380/400 V, 200 kW at 500 V, 250 kW at 690 V, and 185 kW at 1000 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 4 kg.
- AFS305-30-12-13
The ABB AFS305-30-12-13 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 440 V, 290 A at 500 V and 690 V, and 131 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 160 kW at 415 V and 440 V, 200 kW at 500 V, 250 kW at 690 V, and 185 kW at 1000 V. Dimensions are 140 mm width, 180 mm depth, and 225 mm height; weight is 4 kg.
- AFS305-30-12-14
The ABB AFS305-30-12-14 is a three-pole AC contactor with one normally open and two normally closed auxiliary contacts. It is rated for a main circuit of 1000 V and 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 440 V, 290 A at 500 V and 690 V, and 131 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 160 kW at 415 V and 440 V, 200 kW at 500 V, 250 kW at 690 V, and 185 kW at 1000 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 4 kg.
- AFS305-30-12-33
ABB AFS305-30-12-33 is a 3-pole AC contactor, manufacturer ID 1SFL587082R3312. It has three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 305 A at 415 V, 440 V, and 380/400 V, 60 °C, with rated operational power of 160 kW at those voltages. AC-3 breaking capacity is 8 x Ie and making capacity is 10 x Ie. Short-circuit protection uses gG type fuses rated 500 A. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 4 kg.
- AFS305-30-12-34
The ABB AFS305-30-12-34 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. Its main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V, 440 V, and 380/400 V at 60 °C, and 290 A at 500 V and 690 V at 60 °C. Rated operational power AC-3 is 160 kW at 415 V, 440 V, and 380/400 V, and 250 kW at 690 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 4 kg. Manufacturer ID: 1SFL587082R3412.