- NF22E-11 24-60V50/60HZ 20-60VDC
ABB NF22E-11 24-60V50/60HZ 20-60VDC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 4-pole, Contacts configuration: NC x2 + NO x2, and Control voltage1: 24...60V AC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF22E-12
The ABB NF22E-12 is a 4-pole intermediate relay with 2 NO and 2 NC auxiliary contacts. The control circuit voltage is 48 to 130 V at 50 Hz, 48 to 130 V at 60 Hz, and 48 to 130 V DC. Rated operational voltage of the auxiliary circuit is 690 V, with a rated insulation voltage of 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 degrees C. The relay measures 45 mm wide, 77 mm deep, and 86 mm high, weighs 0.27 kg, and uses screw terminals. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NF22E-12 48-130V50/60HZ-DC
ABB NF22E-12 48-130V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 4-pole, Contacts configuration: NC x2 + NO x2, and Control voltage1: 48...130V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF22E-13
The ABB NF22E-13 is an intermediate relay with 2 NO and 2 NC auxiliary contacts. Its control circuit accepts 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. The auxiliary circuit is rated 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Maximum mechanical switching frequency is 6000 cycles per hour. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.27 kg. DIN-rail mounting is TH35-15 or TH35-7.5 according to IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13.
- NF22E-13 100-250V50/60HZ-DC
ABB NF22E-13 100-250V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 4-pole, Contacts configuration: NC x2 + NO x2, and Control voltage1: 100...250V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF22E-14
ABB NF22E-14 intermediate relay, manufacturer ID 1SBH137001R1422, with 2 NO and 2 NC auxiliary contacts. Rated control circuit voltage is 250 to 500 V at 50 Hz, 250 to 500 V at 60 Hz, and 250 to 500 V DC. Rated operational voltage for the auxiliary circuit is 690 V. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Maximum mechanical switching frequency is 6000 cycles per hour; maximum electrical switching frequency is 1200 cycles per hour at AC-15 and 900 cycles per hour at DC-13. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, weighing 0.31 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13. Mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- NF22E-14 250-500V50/60HZ-DC
ABB NF22E-14 250-500V50/60HZ-DC is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of contactor: 4-pole, Contacts configuration: NC x2 + NO x2, and Control voltage1: 250...500V DC. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- NF22EK-11
The ABB NF22EK-11 is an intermediate relay with 2 NO and 2 NC auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.285 kg. The rated control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Rated operational voltage is 690 V for both auxiliary and main circuits. Conventional free-air thermal current is 16 A at 40 °C per IEC 60947-5-1. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards cited are IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, and CSA C22.2 No. 14-13.