- OT400U30
The ABB OT400U30 is a three-pole, front-operated isolating switch intended for base mounting. Its conventional thermal current (Ithe) is 400 A fully enclosed, and the rated insulation voltage is 1000 V according to IEC/EN 60664-1. Rated impulse withstand voltage is 12 kV, with pollution degree 3. Power loss at rated operating conditions is 10 W per pole. The front degree of protection is IP00. Dimensions are 221 mm wide, 220 mm high, and 105 mm deep; net weight is 3 kg (6.7 lb). Mechanical durability is 16000 operating cycles. A handle and shaft are not included, and no lock is provided. Manufacturer ID: 1SCA022748R1490.
- OT400U30C
ABB OT400U30C is a 3-pole, front-operated isolating switch rated 400 A. Conventional free-air thermal current Ith is 400 A at 40 °C. Rated insulation voltage Ui is 1000 V and rated impulse withstand voltage Uimp is 12 kV. Rated operational current is 400 A at 380–415 V, 500 V and 690 V for AC-21A, AC-22A and AC-23A; AC-31B and AC-33B are 400 A at 380–415 V. Rated short-time withstand current Icw is 15 kA rms for 1 s. Standards: UL 98 / IEC 60947-6-1. Front protection IP20, pollution degree 3, mechanical durability 8000 cycles. Screw terminals, tightening torque 30–44 N·m per IEC 60947-1. Base mounting, 251 x 185 x 203 mm, 5.46 kg. Handle and shaft not included.
- OT400U30P
The ABB OT400U30P is a front-operated, non-fusible isolating switch in a 3-pole configuration. It is rated for a conventional thermal current (Ithe) of 400 A fully enclosed and a rated impulse withstand voltage (Uimp) of 12 kV. The switch has a pollution degree of 3 and a front degree of protection of IP00. Mechanical durability is 16000 operating cycles. Power loss is 10 W per pole at rated operating conditions. It uses base mounting and includes a black handle and shaft. Dimensions are 221 mm wide, 220 mm high, and 105 mm deep, with a net weight of 3.1 kg (6.9 lb). The manufacturer ID is 1SCA022748R1570.
- OT400U40
ABB OT400U40 is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301266D0201, Pollution Degree: 3, and Product Net Width: 280 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT400U40C
ABB OT400U40C is a 4-pole, front-operated isolating switch rated 400 A. Conventional free-air thermal current Ith is 400 A at 40 °C. Rated insulation voltage Ui is 1000 V; rated impulse withstand voltage Uimp is 12 kV. Rated operational current is 400 A at 380 to 415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A; AC-31B and AC-33B are 400 A at 380 to 415 V. Rated short-time withstand current Icw is 15 kA rms for 1 s. Standards: UL 98 and IEC 60947-6-1. Front degree of protection is IP20; pollution degree 3. Mechanical durability is 8000 cycles. Dimensions are 305 mm wide, 185 mm high, and 203 mm deep; net weight is 7.66 kg. Screw terminals; tightening torque 30 to 44 N·m per IEC 60947-1. Handle and shaft are not included.
- OT400US03
ABB OT400US03 is a three-pole isolating switch-disconnector for base mounting. Conventional thermal current (Ithe) is 400 A fully enclosed. Rated operational voltage of the main circuit is 1000 V; rated insulation voltage is 1000 V acc. to IEC/EN 60664-1, and rated impulse withstand voltage (Uimp) is 12 kV. Rated operational current AC-22A and AC-23A is 400 A at 380 to 415 V, 500 V, and 690 V. Rated short-circuit making capacity (Icm) is 65 kA at 690 V; rated short-time withstand current (Icw) is 15 kA for 1 s. Standards: IEC 60947-3, UL 98, CSA C22.2 NO.4. Maximum operating voltage UL/CSA is 600 V. Dimensions are 258.9 mm width, 220 mm height, 105 mm depth; net weight 3.6 kg. Front degree of protection IP00, pollution degree 3, lug terminals, tightening torque 42.4 N·m acc. IEC 60947-1. Handle and shaft not included.
- OT400US03K
The ABB OT400US03K is a 3-pole non-fusible isolating switch for base mounting. Its conventional thermal current (Ithe) is 400 A fully enclosed, and the rated operational current AC-22A is 400 A at 380 to 415 V, 500 V, and 690 V. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 12 kV. Power loss is 10 W per pole at rated operating conditions. The switch has a black handle, but the handle and shaft are not included. It supports locking and offers front degree of protection IP00 at pollution degree 3. Mechanical durability is 16000 operating cycles. Dimensions are 281.2 mm wide, 220 mm high, and 105 mm deep, with a net weight of 3.6 kg (7.9 lb).
- OT400US04
ABB OT400US04 is a four-pole, non-fusible isolating switch with base mounting. It has a conventional thermal current (Ithe) of 400 A fully enclosed and a rated insulation voltage (Ui) of 1000 V according to IEC/EN 60664-1. Rated operational current is 400 A at 380 to 415 V, 500 V, and 690 V for AC-22A and AC-23A. Rated impulse withstand voltage (Uimp) is 12 kV, pollution degree 3, power loss 10 W per pole at rated operating conditions, and mechanical durability 16000 operations. Dimensions are 312.9 mm wide, 220 mm high, and 105 mm deep, with a net weight of 4.4 kg (9.7 lb). Front degree of protection is IP00. Handle and shaft are not included. Manufacturer ID: 1SCA022870R6700.