- AF09B-22-00RT-14
The ABB AF09B-22-00RT-14 is a 4-pole AC contactor with 2 main contacts NO and 2 main contacts NC, and no auxiliary contacts. It has a rated operational voltage of 690 V for the main circuit and a rated control circuit voltage of 250 to 500 V at 50 Hz, 60 Hz, or DC operation. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 400 V and 5.5 kW at 500 V and 690 V. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.32 kg. Terminals are ring-tongue type.
- AF09B-30-01-14
The ABB AF09B-30-01-14 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Corresponding AC-3 rated operational power is 4 kW at 415 V and 440 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF09B-30-01K-14
The ABB AF09B-30-01K-14 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.325 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-1 is 25 A at 690 V and 40 °C or 60 °C, and 22 A at 70 °C. Rated operational power AC-3 is 4 kW at 415 V, 440 V, and 380/400 V, 5.5 kW at 500 V and 690 V, and 2.2 kW at 220/230/240 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF09B-30-01RT-14
ABB AF09B-30-01RT-14 AC contactor, manufacturer ID 1SBL137060R1401. Three-pole (3 NO main contacts, 0 NC) with one built-in NC auxiliary contact. Ring-tongue terminals. Rated operational voltage 690 V for main and auxiliary circuits; rated frequency 50/60 Hz. Rated operational power AC-3: 4 kW at 415 V, 440 V, and 380/400 V; 5.5 kW at 500 V and 690 V; 2.2 kW at 220/230/240 V. Rated operational current AC-3: 9 A at 415 V and 440 V, 9.5 A at 500 V, 7 A at 690 V. Rated insulation voltage 690 V per IEC 60947-4-1; rated impulse withstand voltage 6 kV. Dimensions 45 x 77 x 86 mm; net weight 0.32 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF09B-30-10-14
The ABB AF09B-30-10-14 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 9 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, and 7 A at 690 V, at 60 °C. Rated operational power AC-3 is 4 kW at 380/400 V, 415 V, and 440 V, and 2.2 kW at 220/230/240 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF09B-30-10K-14
The ABB AF09B-30-10K-14 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.325 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 9 A at 380/400 V and 415 V, 9.5 A at 500 V, and 7 A at 690 V, at 60 °C. Rated operational power AC-3 is 4 kW at 380/400 V and 415 V, and 5.5 kW at 500 V and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF09B-40-00-14
ABB AF09B-40-00-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The main circuit is rated 690 V at 50/60 Hz; the control circuit is rated 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current Ith is 35 A at 40 °C. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, and 7 A at 690 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 400 V and 5.5 kW at 500 V and 690 V. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF09Z-22-00-20
ABB AF09Z-22-00-20 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The main circuit is rated 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 9 A at 415 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.