- AF146-30-22-31
The ABB AF146-30-22-31 is a 3-pole AC contactor with 3 NO main contacts and 2 NO plus 2 NC auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with conventional free-air thermal current 225 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 146 A at 415 V and 60 °C. Coil control voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 110 mm width, 138.5 mm depth, and 150 mm height; net weight is 1.55 kg. Mechanical durability is 5 million operations. Main terminals are IP00 and coil terminals IP20 according to IEC 60529. Maximum operating altitude without derating is 3000 m.
- AF146-30-22-32
The ABB AF146-30-22-32 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 110 mm wide, 138.5 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, and 90 kW at 440 V, 500 V, and 690 V.
- AF146-30-22-33
The ABB AF146-30-22-33 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 142.5 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, and rated operational power AC-3 is 75 kW at 415 V. Rated making capacity AC-3 is 10 x Ie AC-3; rated breaking capacity AC-3 is 8 x Ie AC-3. Manufacturer ID: 1SFL467001R3322.
- AF146-30-22-34
The ABB AF146-30-22-34 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 142.5 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 55 °C, and rated operational power AC-3 is 75 kW at 415 V. Rated making capacity AC-3 is 10 x Ie AC-3; rated breaking capacity AC-3 is 8 x Ie AC-3.
- AF146-30-22-42
The ABB AF146-30-22-42 is an AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with an impulse withstand voltage of 8 kV. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and at 380/400 V, 90 kW at 440 V, 500 V, and 690 V, and 45 kW at 220/230/240 V. The control circuit is rated 110 to 120 V at 50 Hz and 60 Hz. Dimensions are 110 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg.
- AF146-30-22-43
The ABB AF146-30-22-43 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. Main circuit rated operational voltage is 1000 V at 50/60 Hz. Rated operational current AC-3 is 146 A at 415 V and 60 °C, with rated operational power AC-3 of 75 kW at 415 V and 90 kW at 690 V. Conventional free-air thermal current Ith is 225 A per IEC 60947-4-1 at 40 °C. Coil voltage is 220 to 240 V at 50 Hz and 60 Hz. Dimensions are 110 mm wide, 126 mm deep, and 150 mm high; net weight 1.55 kg. Terminals are double clamp. Manufacturer ID 1SFL467001R4322.
- AF146-30-22B-11
The ABB AF146-30-22B-11 is a 3-pole AC contactor with three normally open main contacts and four auxiliary contacts (two NO, two NC). The main circuit is rated 1000 V and 50/60 Hz, with a rated impulse withstand voltage of 8 kV and insulation voltage of 1000 V per IEC 60947-4-1 and 600 V per UL/CSA. AC-3 rated operational power is 75 kW at 415 V and 380/400 V, 90 kW at 440, 500, and 690 V, and 45 kW at 220/230/240 V. The coil accepts 24 to 60 V at 50 or 60 Hz and 20 to 60 V DC. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg.
- AF146-30-22B-12
The ABB AF146-30-22B-12 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with AC-3 ratings of 146 A at 415 V and 75 kW at 415 V. The control circuit voltage is 48 to 130 V at 50 Hz, 48 to 130 V at 60 Hz, and 48 to 130 V DC. Mechanical durability is 5 million operating cycles. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, weighing 1.3 kg. Main terminals are bars; coil terminals are IP20 and main terminals IP00. Maximum operating altitude without derating is 3000 m.